COLOR IR CAMERA
User’s Manual
21
Using a RS-485 communication, it will be able to control the OSD menu at the
SAMSUNG TECHWIN System Controller or DVR.
(1) The case which it controls from the PC
Using a RS-485 converter, It connects to RS-485 CONTROL TERMINAL outside
camera and serial cable
EX) SERIAL PORT OF THE PC(COM1) — SERIAL CABLE -- RS-485 CONVERTER
-- RS-485 CONTROL TERMINAL
(2)The case which it controls from the DVR or System Controller
It connects the RS-485 CONTROL TERMINAL in the connection terminal of 485
control boards which are connected with the DVR or System Controller.
Connecting to RS-485 CONTROL TERMINAL
• When you construct external control systems for a camera control, please use to
the PELCO-D PROTOCOL.
Notes
CONTROL TERMINAL SPEC
WHITE (TRX+)
RS-485+
BLACK (TRX-)
RS-485-
485 CONTROL BOARD CONNECTION TERMINAL
RS-485 CONTROL TERMINAL
(+)CONNECTION TERMINAL
WHITE (TRX+)
(-)CONNECTION TERMINAL
BLACK (TRX-)
Menu
Connection
COLOR IR CAMERA
User’s Manual
21
COLOR IR CAMERA
User’s Manual
20
RS-485 communication control
Operating Your Camera
SETUP menu
LENS
•
DC
SHUTTER
•
- - - -
•
FLK
(condition and speed control)
WHITE BALANCE control
•
ATW
•
AWC
•
MANUAL
BACKLIGHT
•
OFF
•
LOW
•
MIDDLE
(Backlight compensation)
• HIGH
AGC (Auto Gain control)
•
OFF
•
NORMAL
•
HIGH
SSNR
•
OFF
•
LOW
•
MIDDLE
(Samsung super noise reduction)
•
HIGH
SENS-UP (Low illuminance)
•
OFF
•
AUTO
•
CAMERA ID
•
DAYNIGHT
SPECIAL
•
MOTION DET
•
PRIVACY
•
COMM ADJ
•
IMAGE ADJ
•
RESET
•
RETURN