Samsung SID-562 User Manual Download Page 5

COLOR DOME CAMERA

User Guide

8

COLOR DOME CAMERA

User Guide

9

Do not expose the camera to 

radioactivity.

If it is exposed to radioactivity, For heated CCD, it 
will be out of order.

•  If the camera is exposed to spotlight or object reflecting  strong light, smear or 

 

blooming may occur.

•  Please check that the power satisfies the normal specification before connecting

 

the camera.

Notes

Precautions

 

SID-562 

 

 

2

 

Instruction Manual

3

 

M4 Tapping Screw 4EA 

4

 

M4 Machine Screw 4EA

…………………

5

 

Adapter plate 

6

 

Installation Video Output Cable

5

6

2

Components and Accessories

Overview

8 7

6

4

1

2

3

9

5

3

4

Summary of Contents for SID-562

Page 1: ...Before installing and operating this product please read this manual thoroughly High Resolution WDR V F Dome Camera SID 562 UserGuide ENGLISH ...

Page 2: ...vironment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense WARNING Changes o...

Page 3: ...n Control Support Remote OSD menu control via an RS 485 interface is supported OSD The camera control is convenient by using 9 different foreign language O S D NTSC Korean English Spanish Japanese French Portuguese PAL English French German Spanish Italian Chinese Portuguese Wide Dynamic Range WDR By adopting a proprietary SV IV DSP chip the camera delivers clear high quality pictures even in back...

Page 4: ... and is taking a number of steps to provide customers with more environment friendly products The Eco mark represents Samsung Techwin s will to create environment friendly products and indicates that the product satisfies the EU RoHS Directive This information is provided to ensure your safety and to prevent any losses financial or otherwise Please read it carefully and use the product accordingly...

Page 5: ...mera is exposed to spotlight or object reflecting strong light smear or blooming may occur Please check that the power satisfies the normal specification before connecting the camera Notes Precautions SID 562 2 Instruction Manual 3 M4Tapping Screw 4EA 4 M4 Machine Screw 4EA 5 Adapter plate 6 InstallationVideo Output Cable 5 6 2 Components and Accessories Overview 8 7 6 4 1 2 3 9 5 3 4 ...

Page 6: ... the camera body on the plate make sure the power and the BNC cables pass through their respective designated holes When placing the cable through its side thread it through the hole at the bottom After installation and adjustment of the camera are complete secure the dome cover by turning it clockwise Figure 1 Locking direction Plate pin Unlocking direction Please locate an arrow on bracket for i...

Page 7: ... 1 After mounting the camera on a ceiling adjusting the panning angle for better monitoring area by rotating the pan base 2And then adjust the tilting angle by rotating the tilt base 3 Loosen the rotate base hold screw and adjust rotate base for the best monitoring 4Tighten the rotate base hold screw 73 170 145 195 170 Pan Base Tilt Base Rotate Base Connect the adaptor to the power input connector...

Page 8: ...Control Board Connection Port RS 485 Control Port CONNECTIONTERMINAL RED TRX CONNECTIONTERMINAL WHITE TRX CONTROL CABLE SPEC RED TRX RS 485 WHITE TRX RS 485 RS 485 Communication establishment initial value Menu Configuration Item Camera ID BAUD RATE UART MODE PET PKT Initial value 1 9600 8 NONE 1 ENABLE Setup Menu LENS DC EXPOSURE SHUTTER AGC SENS UP RETURN WHITE BALANCE ATW MANUAL AWC SET OUTDOOR...

Page 9: ...the arrow indicates EXPOSURE 2 Select a desired mode using the Function Setup switch An item with the icon also has sub menus To select a sub menu select an item with the icon and press the Function Setup switch An item with the icon is unavailable due to function settings Notes Operating Your Camera EXPOSURE Using this function you can control screen brightness 1 When the SETUP menu screen is dis...

Page 10: ...el the brighter the screen but the more likely it is that an after image will appear Although Noise Spots and Whitish symptoms may occur in SENS UP operation when the zoom level is increased this is normal Notes Use theWhite Balance function to adjust the screen color 1 When the SETUP menu screen is displayed select White Bal by using the Function Setup switch so that the arrow indicates White Bal...

Page 11: ...ion angle for the bestWDR performance If you increase LIMIT the image may be distorted In a dark environment the HLC is only activated when a high light that is larger than a certain area is present The HLC is not activated in light or overly dark conditions If the Color Rolling symptom is occurred while using WDR function change sync mode to L L For more information about SYNC function refer to p...

Page 12: ...l illumination Notes MAIN SETUP 1 LENS DC 2 EXPOSURE 3 WHITE BAL ATW 4 BACKLIGHT OFF 5 SSNR ON 6 DAY NIGHT AUTO 7 IMAGE ADJ 2 Select a desired mode using the Function Setup switch according to the picture display you want IMAGE ADJ 2 Select a desired mode using the Function Setup switch 1 When the SETUP menu screen is displayed select IMAGE ADJ by using the Function Setup switch so that the arrow ...

Page 13: ...ll be displayed on the monitor screen even if you enter one Only English is available in this mode Use the Function Setup switch to move to a desired letter and select the letter by pressing the Function Setup switch Repeat this to enter multiple letters You can enter up to 15 letters Enter a title move the cursor to POS and press the Function Setup switch The entered title appears on the screen S...

Page 14: ...ODE Determines whether to use the area selected in the AREA SEL and the size and position of the area MASK COLOR Determine area color You can select Gray Green Red Blue Black White The chance of resolution decrease is existed because DIS function uses the digital zoom DIS doesn t operate when background illumination is too low DIS doesn t operate when object pattern is monotonic as like sky or whi...

Page 15: ... 562WN SID 562WP Ivory color base model Refer to the following table if you are experiencing trouble with your camera Contact an authorized technician if the table does not provide you with a solution to the trouble RS 485 Communication establishment initial value Item Camera ID BAUD RATE UART MODE RET PKT Initial value 1 9600 8 NONE 1 ENABLE 485 Control Board Connection Port RS 485 Control Port C...

Page 16: ...ment Type Environment CCTV Camera Model Name SID 562P WP Beginning Serial NO S8110001 Year of Manufacture 2008 12 01 Conformance to EN 50081 1 1992 EMC Directive 89 336 EEC and 92 31 EEC EN 50130 4 1996 We the undersigned hereby declare that the equipment specified above conforms to the above Directive s Manufacturer SAMSUNGTECHWIN CO LTD LegalRepresentativeinEurope Signature Signature Full Name B...

Page 17: ...TEL 82 31 740 8151 8 FAX 82 31 740 8145 SAMSUNG TECHWIN EUROPE CO LTD Samsung House 1000 Hillswood Drive Hillswood Business Park Chertsey Surrey UNITED KINGDOM KT16 OPS TEL 44 1932 45 5300 FAX 44 1932 45 5325 SAMSUNG TECHWIN AMERICA Inc 1480 Charles Willard St Carson CA 90746 UNITED STATES Tol Free 1 877 213 1222 FAX 1 310 632 2195 www samsungcctvusa com SALES NETWORK ...