Mobilchips
SGH-E860V Flow Chart of Troubleshooting
2-
23
2-2-2. DCS Rx
Normal condition
catch the
channel ?
Check F100
pin 6
≥
-65 dbm ?
Check U101
pin 18, 19
≥
-
65dBm ?
Yes
No
No
Check F100
pin 12,13
≥
-65
dbm ?
Yes
No
Yes
Check ANT,
C112,144,L100
Resolder or change
CN100, C109
Resolder or change
F100
Resolder or change
C116, 117, L104
CONTINOUS RX ON
RF INPUT : 698CH
AMP : -50dbm
Check U101
pin 32 = 2.8V?
Yes
Resolder or change
U401
Yes
No
No
Resolder or change
U200