66_
functional description
functional description
English
English
_ 67
FUNCTIONAL DESCRIPTION
PTZ Trace
Main Menu/Sequence Setting/PTZ Trace
Maximum 4 patterns of the manual operation paths
(for Pan, Tilt, Zoom and Focus) are memorized and
replayed.
Replay :
Replays a route saved by the Trace function. Use
the OSD button to stop the replay.
Replay Once :
Replays a saved Trace route once.
Memorize :
Up to 120 seconds of a memory can be saved.
The memory duration varies depending on the
diffi culty level of the PTZ Trace action. As a trace is
saved, the remaining capacity of the memory card
is displayed. When the memory card is full, it turns
off with a message, "Mem. Left: 000%", on the
screen.
*
Use the OSD On button to pause while saving a
trace. (When using the SCC-3100A/SCC-1000
controller)
* When Using Different Protocols
Protocol
Product
Memorize Pause
PELCO-D/P
KBD300A
Ack, Iris Open
SEC
SCC-5000
OSD On, Iris Open
PANASONIC
WV-CU161C
OSD ON
VICON
V1300X-DVC
Iris Open
HONEYWELL
HTX-3000
Iris Open
AD
.
OSD On, Iris Open
GE
KTD-405
Iris Open
BOSCH
.
Iris Open
Clear :
Deletes a saved Trace route.
►
•
•
•
•
Sequence Setting
Preset
Swing SEQ
Group SEQ
Tour SEQ
PTZ Trace
Auto Run
Power On Resume
ON
Main Menu
Camera Setting
Sequence Setting
P/T Setting
OSD Setting
Alarm Setting
Initialize
Password Setting
Status
PTZ Trace
Trace 1
Trace 2
Trace 3
Trace 4
PTZ Trace 1
Replay
Replay Once
Memorize
Clear
Auto Run
Main Menu/Sequence Setting/Auto Run
If there is no controller operation by the user for a
certain time, the sequence operation designated by
the user will be executed.
Mode :
HOME
: Auto run Home Position (Refet to the
Preset Menu.)
PRESET
: Auto run a selected preset number.
SWING
: Auto run a selected Swing mode.
GROUP
: Auto run a selected Group mode.
TOUR
: Auto run a selected Tour mode.
TRACE
: Auto run a selected trace mode.
A.PAN
: Auto run a 360-degree pan. To activate
the panning command, you need to set
up the camera's tilt angle and auto pan
speed manually.
SCHEDULE : Schedule a sequencing action by
day and time. Refer to the next
page.
Time :
Enables setting up an Auto Run duration. (The
duration can be 5~30 seconds, or 1~5 minutes.)
►
•
-
-
-
-
-
-
-
-
•
Sequence Setting
Preset
Swing SEQ
Group SEQ
Tour SEQ
PTZ Trace
Auto Run
Power On Resume
ON
Main Menu
Camera Setting
Sequence Setting
P/T Setting
OSD Setting
Alarm Setting
Initialize
Password Setting
Status
Auto Run
Mode
OFF
Time
20 SEC