20_
installing your camera
installing your camera
English
English
_ 21
INSTALLING YOUR CAMERA
COMMUNICATION PROTOCOL DIP SWITCH
SETTINGS (SW2)
Coaxial communication automatically detects signals, and so does not require a
separate communication setup process.
Protocol Settings
Select a communication protocol for the camera
No
Protocol
SW2-#1
SW2-#2
SW2-#3
SW2-#4
1
AUTO DETECT
OFF
OFF
OFF
OFF
2
Samsung-T
OFF
OFF
OFF
ON
3
Pelco-D
OFF
OFF
ON
OFF
4
Pelco-P
OFF
OFF
ON
ON
5
Samsung-E
OFF
ON
OFF
OFF
6
Panasonic
OFF
ON
OFF
ON
7
Vicon
OFF
ON
ON
OFF
8
Honeywell
OFF
ON
ON
ON
9
AD
ON
OFF
OFF
OFF
10
GE
ON
OFF
OFF
ON
11
BOSCH
ON
OFF
ON
OFF
12
Reserved
ON
OFF
ON
ON
13
Reserved
ON
ON
OFF
OFF
14
Reserved
ON
ON
OFF
ON
15
Reserved
ON
ON
ON
OFF
16
Reserved
ON
ON
ON
ON
Baud Rate Settings
Select the transfer speed of a selected communication protocol.
No.
Baud Rate(BPS)
SW2-#5
SW2-#6
1
2,400
ON
ON
2
4,800
ON
OFF
3
9,600
OFF
OFF
4
19,200
OFF
ON
*
❖
❖
ON
ON
OFF
SW2
SW2 Pin No.
Purpose
1~4
Protocol Settings
5~6
Baud Rate Settings
7
Response Mode Settings
8
Termination Settings
Communication Response Settings
Select a communication response method for the camera and controller: Response or
No Response.
Function
ON
OFF
SW2- #7
Response Mode Switch
Response
No Response
Termination Settings
To prevent the attenuation of communication signals between the camera and
controller, the items at the end of line must be set up with the termination settings.
Camera Input Position
SW2- #8
Termination of Longest Path
ON
On the Path
OFF
This model is provided with factory defaults of all DIP switches set to OFF. The default
settings are shaded in the table.
To use a third party controller with this product, please contact our After-Sales Service
or Technology Department.
Controls Using Different Protocols
AD Protocol
VICON Protocol
GE Protocol
Entering Camera OSD
3+Auxilary ON
IRIS OPEN
IRIS OPEN
Exiting Camera OSD
3+Auxilary OFF
IRIS CLOSE
IRIS CLOSE
ENTER
IRIS OPEN
IRIS OPEN
IRIS OPEN
ESC
IRIS CLOSE
IRIS CLOSE
IRIS CLOSE
ö
Control with the SSC-5000 Controller
Protocol
Enter
Esc
Samsung-T
Focus Far
Focus Near
Samsung-E
Iris Open/Focus Far
Iris Open/Focus Near
Note that LCD monitor does not switch to OSD mode and the Joystick will not provide
Enter operation, when using the OSD menu with Samsung-E protocol.
CAMERA ID DIP SWITCH SETTINGS (SW1)
To set up camera IDs, refer to the “Camera ID Chart” next.
❖
❖
*
M
ON
ON
OFF
SW1