20_
connection & installation
connection & installation
Camera Backup Settings
These settings are useful when the camera or its install base are damaged or malfunctions occur.
When replacing the camera or its install base, you can transfer existing presets and sequence
information to the replacement using these settings.
Backup Function
SW2- #9
SW2- #10
Backup(IB
D)
OFF
OFF
Backup(D
IB)
ON
OFF
Backup Disable
-
ON
Backup(IB
D) : Enables transferring the current camera's sequence information to a new camera.
Backup(D
IB) : Enables transferring the current camera's sequence information to a new install base.
IB: Install base, D: Dome Camera
■
[Current Time] is not backed up from install base to camera.
This model is shipped from the factory with all the communication dip switches (SW2) set to OFF, and the default values
are shaded as shown in the setting table.
If you want to use a third-party controller for controlling the camera, contact us at the call center or visit our website for
details.
AD Protocol Control Method
Input Camera OSD: 3+Auxiliary On
Output Camera OSD: 3+Auxiliary Off
Enter: IRIS Open
ESC: IRIS Close
For more information about the protocols, refer to our offi cial website.
http://www.samsungtechwin.com/
-
-
Ú
I
1.
2.
3.
4.