SAMSUNG Proprietary-Contents may change without notice
3-2
SCH-A302
Tune-up Rrocedure & Test Procedure list
3-2. Test Cable Connections
1
MHC 172
2
RF CABLE (1.4 dB Loss for CDMA800 and AMPS, 2.1 dB Loss for PCS)
3
BNC CONECTOR (RF)
4
PLUG CONNECT TO SCH-A302
5
DATA CABLE
6
Dsub 25PIN CONNECTOR (DATA)
3. Test Cable Description for SCH-A302
3-1. Test Cable
1
2
3
4
5
6
Change to Test Mode
A. To Change the phone’s state from Normal Mode to Test Mode, You should enter the following keys.
: Press [ 7 5 9 # 8 1 3 5 8 0 "(A+Y)"]
B. The Command “2 1” is mode and channel change.
“20363”
Channel number
Mode : CDMA
and Push the [OK] Key to save.
C. The command “0 1” is Suspend.
D. To finish the Test Mode, You should enter the command “0 2”.
Channel Selection and Tx Power Output Level Control
1. CDMA
A. Enter to Test Mode [
7 5 9 # 8 1 3 5 8 0 "(A+Y)"]
B. The command “2 1” is mode and channel change.
“20363”
Channel number
Mode : CDMA
Push the [OK] Key to save.