S3F84B8_UM_REV 1.00
4 CONTROL REGISTERS
4-6
4.1.2 AMTDATA — ANTI-MIS-TRIGGER DATA REGISTER: F6H, BANK0
Bit Identifier
.7
.6
.5
.4
.3
.2
.1
.0
RESET Value
0 0 0 0 0 0 0 0
Read/Write
R/W R/W R/W R/W R/W R/W R/W R/W
Addressing Mode
Register addressing mode only
.7–.0
Anti-mis-trigger time= (AMTDATA
4)/f TST
NOTE:
0 < TST (setting time) < 4/fpwmclk
4.1.3 BTCON — BASIC TIMER CONTROL REGISTER: D3H, BANK0
Bit Identifier
.7
.6
.5
.4
.3
.2
.1
.0
RESET Value
0 0 0 0 0 0 0 0
Read/Write
R/W R/W R/W R/W R/W R/W R/W R/W
Watchdog Timer Function Enable Bit
1 0 1 0
Disables
watchdog
timer
function.
.7–.4
Others
Enables watchdog timer function.
Basic Timer Input Clock Selection Code
0 0 f
OSC
/4096
0 1 f
OSC
/1024
1 0 f
OSC
/128
.3–.2
1 1 Invalid
setting
Basic Timer 8-Bit Counter Clear Bit
0 No
effect.
.1
1
Clears the basic timer counter value.
Basic Timer Divider Clear Bit
0 No
effect.
.0
1
Clears both the dividers.
NOTE:
When you write a “1” to BTCON.0 (or BTCON.1), the basic timer divider (or basic timer counter) is cleared. The bit is
then automatically cleared to “0”.