9.10 Brightness/Color Calibration
Online Calibration
In online calibration, NovaCLB connects with NovaLCT-Mars through network. Data and
instructions for LED display calibration are exchanged through the network. Shown in
Fig.9-13 is the page for online calibration.
Fig 9-13
Current Serial Port
This is the serial port through which the LED display to be calibrated is connected to the
computer.
Current Screen
The LED displays connected to the computer will be list in this panel. Select the LED display
to be calibrated from the list.
Local IP
This is the IP address that NovaLCT-Mars listens to. It is actually an IP of the computer on
which NovaLCT-Mars is running.
Port
This is the port that NovaLCT-Mars listens to.
Reconnect
Click this button to terminate the current listening process and start a new listen process
using the settings of Local IP and Port.
Communication Log
Records of the communication between NovaCLB and NovaLCT-Mars are listed is this
panel.
Enable Calibration
This option is to enable or disable LED display calibration using calibration coefficients.
Summary of Contents for P10
Page 3: ...3 10 1 Cleaning 104 10 2 Calibration 105 10 3 Replacement steps 106 11 Appendix 119 ...
Page 12: ...12 3 2 Product Appearance ...
Page 13: ...13 ...
Page 14: ...14 3 3 Product design Decomposition chart ...
Page 15: ...15 Assembly drawing ...
Page 16: ...16 3 4 Product main components Module Power Supply Receiving Card Monitoring Card ...
Page 17: ...17 Fan Hub board Power data cables 16pcs DC power cables 8PCS and Flat cables 16 pcs ...
Page 35: ...35 Installation of cabinets Fixing of connect plate ...
Page 42: ...42 8 2 Port of Cabinet and serial number paint ...
Page 59: ...59 ...
Page 68: ...68 ...