OfficeServ 7100
PROGRAMMING
TECHNICAL MANUAL
PART 2 APRIL 2007
MMC: 209
ASSIGN ADD-ON MODULE
DESCRIPTION:
Designates to which keyset a 64 button module is assigned to. An OfficeServ 7100
system will support up to 2 (two) 64 button modules per station.
NOTE: The 64 button modules do not have a speaker or microphone so they will
not have the off-hook voice announce option.
PROGRAM KEYS
UP & DOWN
Used to scroll through options
KEYPAD
Used to enter selections
SOFT KEYS
Move cursor left and right
RELEASE
Used to store data and advance to next MMC
HOLD
Clears
previous
entry
ACTION
DISPLAY
1. Press TRANSFER 209
Display shows first AOM
[301] 64B MASTER
MASTER:NONE
2. Dial AOM number
OR
[301] 64B MASTER
MASTER:NONE
Use UP or DOWN to scroll through AOM
numbers and use soft keys to move cursor.
3a. Enter station number, e.g., 301
OR
[301] 64B MASTER
MASTER:201
Use UP or DOWN for selection of stations
OR
Dial the number using the dial pad.
4. Press TRANSFER to store and exit
OR
Press SPEAKER to save and advance to next
MMC.
DEFAULT DATA: NONE FOR MASTER
RELATED ITEMS: NONE
Home Page
Table of Contents