OfficeServ 7100
PROGRAMMING
TECHNICAL MANUAL
PART 2 MAY 2009
MMC: 722
STATION KEY PROGRAMMING
DESCRIPTION:
Allows the customizing of programmable keys on specific electronic keysets, or 64
button module on the OfficeServ 7100 system. For AOM’s and 64 button DSS box’s
all buttons are set as DS keys by default. Features are entered via dial pad keys by
pressing the dial pad number the required number of steps to select the feature. For
example, for OHVA, the number 6 is pressed three times. If the BOSS key is
required, press 2 for the first letter B and then use the UP or DOWN key to change
the selection from BARGE to BOSS.
DIAL KEYPAD
COUNT
1 2 3 4
DIAL 2
ABAND BARGE CAD
DIAL 3
DGIALM EP FAUTO
DIAL 4
GPIK HDSET IG
DIAL 5
LANREQ LCR LISTN
DIAL 6
MMPA NEW OHVA
DIAL 7
PAGE PAGE RB SETMG
DIAL 8
TCLIP UA VM
DIAL 9
WAKEUP XCHIN WAKEUP
PROGRAM KEYS
UP & DOWN
Used to scroll through options
KEYPAD
Used to enter selections
SOFT KEYS
Move cursor left and right
SPEAKER
Used to store data and advance to next MMC
HOLD
Used to clear previous entry
ACTION
DISPLAY
1. Press TRANSFER 722.
Display shows.
[201] KEY PROG.
01:CALL1
→
2. Enter selected station number (e.g., 205)
OR
[205] KEY PROG.
01:CALL1
→
Press UP or DOWN key to select station.
Press RIGHT soft key to move cursor.
Home Page