TOLL DENY TABLE
DESCRIPTION:
Provides a way to make toll restriction (call barring) very easy and flexible. There are
500 entries in the deny table and each entry index can be assigned to a class of
service. Each index can have up to 12 digits. With the use of wild cards (MMC 704
Assign Wild Character), more flexibility can be built into toll restriction. Wild cards can
be used repeatedly in the dial string, limited only to what is allowed or denied in MMC
704. There are six toll levels, B to G, that are programmable. Toll level A is set as
unrestricted by default and toll level H is set as in-house only by default.
PROGRAM KEYS
UP & DOWN
Used to scroll through options
KEYPAD
Used to enter selections
SOFT KEYS
Move cursor left and right
SPEAKER
Used to store data and advance to next MMC
HOLD
Used to clear previous entry
WILD CARD KEY
DIAL WILD
CARD
A X
B Y
C Z
ACTION
DISPLAY
1.
Press TRANSFER 702.
Display shows.
DENY(001):BCDEFG
:000000
2.
Dial index number 001-500 (e.g., 005)
OR
DENY(005):BCDEFG
:000000
Press UP or DOWN key to select index and
press RIGHT soft key to move cursor and
enter toll pattern via dial pad (e.g., 212)
DENY(005):BCDEFG
212 :000000
OR
Enter wild card (e.g., 21X) from above list and
press RIGHT soft key to move cursor to
DENY(005):BCDEFG
21X :000000
COS
options.