English 5
Installation requirements
IMPORTANT:
If installing a range hood or microwave hood combination above the cooktop,
follow the range hood or microwave hood combination installation instructions for
dimensions and clearance above the cooktop surface.
G
F
A
C
E
E
D
B
Cooktop
Rear Wall
Countertop
Junction box
Minimum distance to
combustible side wall above
countertop (both sides)
NZ30*******
NZ36*******
A
28
1
/
2
” - 28
11
/
16
” (724 mm - 728 mm)
33
7
/
8
” - 34” (860 mm - 864 mm)
B
19
9
/
16
” - 19
5
/
8
” (497.4 mm - 499.4 mm)
19
1
/
8
” - 19
3
/
16
” (485.6 mm - 487.6 mm)
C
Min 1
1
/
8
” (28 mm). Between cutout and the wall behind the cooktop
D
Min 1
1
/
2
” (38 mm). From front edge of cutout and front edge of countertop
E
Min 1” (26 mm). Distance nearest left and right side combustible surface above
cooktop.
F
Junction box or outlet 10” (254 mm) maximum from right-hand side of cabinet
G
Junction box or outlet 15” (381 mm) minimum from bottom of countertop
Product dimensions
B
A
D
C
E
F
Cabinet
30” (mm)
36” (mm)
A
Frame Depth
21
1
/
4
” (540)
21
1
/
4
” (540)
B
Frame width
30” (762)
36” (914)
C
Case Depth
19
1
/
2
” (494.6)
19” (481.6)
D
Case Width
28
3
/
8
” (720)
33
3
/
4
” (856.6)
E
Conduit Case Height
4” (101)
4” (101)
F
Case Height
3
1
/
8
” (80.5)
3
1
/
8
” (80.5)
CHEF-INDU_NZ30M9880_NZ36M9880_DG68-00827B-01_EN+MES+CFR.indb 5
5/25/2018 7:07:52 PM
Summary of Contents for NZ36M9880 Series
Page 11: ...Memo CHEF INDU_NZ30M9880_NZ36M9880_DG68 00827B 01_EN MES CFR indb 11 5 25 2018 7 07 53 PM ...
Page 23: ...Notas CHEF INDU_NZ30M9880_NZ36M9880_DG68 00827B 01_EN MES CFR indb 11 5 25 2018 7 07 58 PM ...
Page 35: ...Notes CHEF INDU_NZ30M9880_NZ36M9880_DG68 00827B 01_EN MES CFR indb 11 5 25 2018 7 08 03 PM ...