4 English
Installation requirements
Installation requirements
Location requirements
IMPORTANT:
Observe all governing codes and ordinances.
•
Cabinet opening dimensions that are shown must be used.
Recessed installation area must provide complete enclosure around the
recessed portion of the cooktop.
•
Grounded electrical supply is required. See “Electrical Requirements” section.
NOTE
It is recommended to install the juction box on right side of the cabinet.
If installing the junction box near the left side, make sure the junction box does
not interfere with the cooktop (by concealing the junction box inside the wall).
IMPORTANT:
To avoid damage to your cabinets, check with your builder or
cabinet supplier to make sure that the materials used will not discolor, delaminate
or sustain other damage. This cooktop has been designed in accordance with
the requirements of UL and CSA International and complies with the maximum
allowable wood cabinet temperatures of 194 °F (90 °C).
Installation requirements
Tool and parts
Tools you will need
Pencil
Phillips Head Screwdriver
Ruler or Straightedge
Safety Glasses
Saber Saw
1
/
8
” Drill Bit & Electric or
Hand Drill
Parts needed
•
A UL listed or CSA approved connector for
1
/
2
” (1.3 cm) diameter conduit\
•
UL listed wire connectors
Check local codes. Check existing electrical supply. See the “Electrical
requirements” section.
It is recommended that all electrical connections be mafe by a licensed, qualified
electrical installer.
Parts included
6 screw
(M4 L10 2 ea,
M4 L16 2 ea,
UNC 24
3
/
16
L75 2 ea)
Bracket Guide: 2ea
Foam Tape
CHEF-INDU_NZ30M9880_NZ36M9880_DG68-00827B-01_EN+MES+CFR.indb 4