12 English
Ins
tallation
Installation
Power connection
01 02 03
L
N
01
BROWN or BLACK
02
BLUE or WHITE
03
YELLOW and GREEN
Plug the oven into an electrical socket. If
a plug-type socket is not available due to
allowable current limitations, use a multi-
pole isolator switch (with at least 3 mm
spacing in-between) in order to meet safety
regulations. Use a power cord of sufficient
length that supports the specification H05
RR-F or H05 VV-F, min. 1.5~2.5 mm².
Rated current(A)
Minimum cross-
sectional area
10 < A
≤
16
1.5 mm
2
16 < A
≤
25
2.5 mm
2
Check the output specifications on the label
attached to the oven.
Open the rear cover of the oven using a
screwdriver, and remove the screws on the
cord clamp. Then, connect the power lines to
the relevant connection terminals.
The ( )-terminal is designed for
earthgrounding. First connect the yellow
and green lines (earthgrounding), which
must be longer than the others. If you use
a plug-type socket, the plug must remain
accessible after the oven is installed.
Samsung is not responsible for accidents
caused by missing or faulty earthgrounding.
WARNING
Do not step on or twist the wires during
installation, and keep them away from heat-
emitting parts of the oven.
NV73J7740RS_EU_DG68-00614E-01_EN.indd 12
2015-05-18 3:37:20