Page 1: ......
Page 2: ...p system This technology is up to 300 more efficient than electrical heating so you can further reduce its running cost Now meet year round needs with one air conditioner A Look for Everywhere The elegant and harmonious design gives priority to the esthetics of your space and complements any of your existing interior décor With its soft color and rounded edge shape the new air conditioner adds cla...
Page 3: ...d help and information online at www samsung com Important safety symbols and precautions WARNING Hazards or unsafe practices that may result in severe personal injury or death CAUTION Hazards or unsafe practices that may result in minor personal injury or property damage CAUTION To reduce the risk of fire explosion electric shock or personal injury when using your air conditioner follow these bas...
Page 4: ...a damaged or dusted power plug power cable or loosened power receptacle Potential risk of fire or electric shock Install an exclusive circuit breaker and short circuit breaker for the air conditioner Potential risk of electric shock or fire Do not insert anything such as fingers or branches into the air conditioner vents while the air conditioner is running Keep the children away from the air cond...
Page 5: ... measures to prevent the allowable concentration from being exceeded If the refrigerant leaks and cause the concentration limit to be exceeded hazards due to lack of oxygen in the room may result If the indoor unit gets wet turn the power off immediately and call your nearest contact center Potential risk of fire or electric shock Always make sure that the power supply is compliant with current sa...
Page 6: ...al risk of malfunction electric shock or fire if repairs or installations are attempted by a non qualified service technician Do not spray flammable gases such as insecticide near the air conditioner Potential risk of electric shock fire or unit malfunction Do not open the front grille during operation Potential risk of electric shock or unit malfunction Cool air should not flow directly towards p...
Page 7: ...r disabled people The packaging material and used batteries of the remote controller optional must be disposed of in accordance with the national standards The refrigerant used in the air conditioner must be treated as chemical waste Dispose the refrigerant following national standards Have a qualified service technician install the air conditioner and perform a trial operation Firmly connect the ...
Page 8: ...r ability to perform routine maintenance and repairs The units components must be accessible and that can be disassembled in conditions of complete safety either for people or things For this reason where it is not observed as indicated into the Installation Manual the cost necessary to reach and repair the unit in safety as required by current regulations in force with slings trucks scaffolding o...
Page 9: ...re indicates that the product and its electronic accessories e g charger headset USB cable should not be disposed of with other household waste at the end of their working life To prevent possible harm to the environment or human health from uncontrolled waste disposal please separate these items from other types of waste and recycle them responsibly to promote the sustainable reuse of material re...
Page 10: ...anual to get started and to make the best use of the air conditioner GETTING READY TO SET UP THE AIR CONDITIONER First select a location to set up the air conditioner Selecting the best location You may set up your air conditioner under the ceiling or on the floor depending on your installation environment Consider interior design available space and the origin of cool or warm air to select the be...
Page 11: ...air conditioner before use CHECKING THE PART Your air conditioner and display may look slightly different from the illustration shown above depending on your model Main parts Air flow blade up down Air flow blade right left Front grille Remote control sensor Defrosting indicator Except cooling only models Filter sign indicator Fan indicator Timer indicator Operation indicator Power button display ...
Page 12: ... happens The air conditioner stops heating The air conditioner will operate automatically in De ice mode for 10 minutes The steam produced on the outdoor unit in De ice mode is safe No intervention is required after about 10 minutes the air conditioner operates again normally The unit will not operate when it starts to de ice Fan Fan may not operate for about 3 5 minutes at the beginning to preven...
Page 13: ... the ceiling or on the floor depending on your installation environment 1 Move the each set of inner air flow blades left or right to keep the air flow direction in a constant position you prefer Be extremely careful with your fingers while adjusting the Horizontal air flow direction There is a potential risk of personal injury when the unit is mishandled PUSH PUSH PUSH PUSH CAUTION ...
Page 14: ...area by using a soft brush Do not use Benzene or Thinner They may damage the surface of the air conditioner and can create a risk of fire CLEANING THE FILTER When cleaning the filter make sure to unplug the power from the unit Washable foam based Air filter captures large particles from the air The filter is cleaned with a vacuum or by hand washing 1 Open the front grille Push the PUSH tabs locate...
Page 15: ...ith running water and dry it in a ventilated area 5 Insert the Air filter back in its original position 6 Close the front grille After cleaning the filter press the Filter Reset button on the remote control for 2 seconds to reset the filter schedule For best conditions repeat every two weeks If the Air filter dries in a confined or humid area odors may generate If it occurs re clean and dry it in ...
Page 16: ...t Clean the air filter 1 Clean the condensate drain pan 2 Thoroughly clean the heat exchanger 2 Clean the condensate drain pipe 2 Replace the remote control batteries 1 Outdoor unit Clean the heat exchanger on the outside of the unit 2 Clean the heat exchanger on the inside of the unit 2 Clean the electric components with jets of air 2 Verify that all the electric components are firmly tightened 2...
Page 17: ...heat pump is heating Anti protection of internal battery The compressor will be off to protect internal battery when the air conditioner operates in Cool mode Protect compressor The air conditioner does not start operating immediately to protect the compressor of the outdoor unit after it has been started If the heat pump is operating in Heat mode De ice cycle is actuated to remove frost from an o...
Page 18: ...le for cooling model The fan speed does not change Check if you selected Auto or Dry mode The air conditioner automatically adjusts the fan speed to Auto in Auto Dry mode Timer function does not set Check if you press the Power button on the remote control after you have set the time Odors permeate in the room during operation Check if the appliance is running in a smoky area or if there is a smel...
Page 19: ...to have either water blow off or drops on the floor HEATING 27 C or less 20 C to 24 C Internal protection triggers and the air conditioner will stop DRYING 18 C to 32 C 15 C to 43 C Condensation may occur on the indoor unit with risk to have either water blow off or drops on the floor The standardized temperature for heating is 7 C If the outdoor temperature drops to 0 C or below the heating capac...
Page 20: ...SUNG 0900 7267864 0 10 Min www samsung com NORWAY 815 56 480 www samsung com POLAND 0 801 1SAMSUNG 172678 022 607 93 33 www samsung com PORTUGAL 80820 SAMSUNG 726 7864 www samsung com SLOVAKIA 0800 SAMSUNG 726 7864 www samsung com SPAIN 902 1 SAMSUNG 902 172 678 www samsung com SWEDEN 0771 726 7864 SAMSUNG www samsung com U K 0845 SAMSUNG 7267864 www samsung com EIRE 0818 717100 www samsung com SW...
Page 21: ...for purchasing this Samsung product To receive more complete service please register your product at www samsung com register Convertible Type Series Ceiling Floor FH EAV NS CDXEA I F S E P R G D DB98 32658A 2 100 Recycled Paper 100 Recycled Paper 100 Recycled Paper ...