Samsung MXD-K000PN Installation Manual Download Page 1

Air conditioner

Installation manual

Packaged DOAS Kit MXD-K000PN

 

Thank you for purchasing this Samsung product.

 

Before operating this unit, please read this Installation manual carefully and retain it for future 
reference.

SOL Packaged DOAS Kit 북미향 IM_EN_DB68-08395A-00.indd   1

2019-03-28   오후 3:36:55

Summary of Contents for MXD-K000PN

Page 1: ...AS Kit MXD K000PN Thank you for purchasing this Samsung product Before operating this unit please read this Installation manual carefully and retain it forfuture reference SOL Packaged DOAS Kit 북미향 IM_EN_DB68 08395A 00 indd 1 2019 03 28 오후 3 36 55 ...

Page 2: ...ackaged DOAS Kit 5 Packaged DOAS Kit Checking Operation 8 LED indication 7 SEGMENT indication Note on Packaged DOAS Kit and DMS operation ErrorCodes 10 ALC Controller 11 Setting the ALC Controllerfor Packaged DOAS Kit SOL Packaged DOAS Kit 북미향 IM_EN_DB68 08395A 00 indd 2 2019 03 28 오후 3 36 56 ...

Page 3: ...prevent electric shock Unplug the powerplug from the wall socket Do NOT disassemble FOR INSTALLATION WARNING Contact a service centerforinstallation Failure to do so may result in product malfunction water leakage electric shock and fire You must use the supplied wire forinstallation Failure to do so may result in fire or damage to a Packaged DOAS Kit All electric works should complywith local reg...

Page 4: ...n component damage or product malfunction Do not install the product in a place where acid oralkali liquid orspecial sprays are used Failure to do so may result in electric shock orabnormal operation FOR Operation WARNING Do not remodel orrepairthe Packaged DOAS Kit yourself Failure to do so may result in product malfunction electric shock and fire so contact a service centerfor repair When dispos...

Page 5: ...d communication cable of the Packaged DOAS Kit When a Packaged DOAS Kit is installed you can perform a centralised control of DMS CN4 CN3 RED CN2 BLK CN4 CN3 RED CN2 BLK F1 F2 R1 R2 24VAC VDC VDC BROWN SKY BLUE NET NET Shield RED BLUE 24VAC Fresh Access Packaged DOAS Terminal Block Mark Mark SKY BLUE BROWN RED Modbus SKY BLUE BLUE FCU Interface module MIM F10N RED BLUE BROWN RED BLUE DMS Note Note...

Page 6: ...OAS have been installed To set No Set Hold BAS Control set as in the following table Default Hold BAS Control This function is only applicable when Packaged DOAS ALC Controller is connected Hold BAS Control Monitors the setting value of Occupancy Control Option of ALC Controller and keeps it on 2 BAS Control continuously No Set No Set Occupancy Control Option Purpose Use when you want to control l...

Page 7: ... DOAS Kit to each FCU Interface module CN4 CN3 RED CN2 BLK CN4 CN3 RED CN2 BLK CN4 CN3 RED CN2 BLK CN4 CN3 RED CN2 BLK DMS2 5 Modbus communication Fresh Access Packaged DOAS Packaged DOAS Kit Max16 S NET3 R1 R2 F1 F2 F1 F2 IndoorUnit FCU Interface module MIM F10N OutdoorUnit SOL Packaged DOAS Kit 북미향 IM_EN_DB68 08395A 00 indd 7 2019 03 28 오후 3 36 58 ...

Page 8: ...n The tracking of Packaged DOAS Kit will proceed as the following Display in normal operation Ad and are displayed on the first and second segment for1 second Example Address SEGMENT 00 15 The address of the Packaged DOAS Kit can be set to a value from 0 to15 Displaywhen an erroroccurs E and are displayed on the first and second segments for1 second Displays and for1 second This action will repeat...

Page 9: ...panel is disabled The current temperature and mode are only displayed You can change the set temperatures for cooling heating and dehumidification and the occupied and unoccupied ranges of temperature setting Cool 60 to 80 Dry 60 to 80 Heat 60 to 80 SOL Packaged DOAS Kit 북미향 IM_EN_DB68 08395A 00 indd 9 2019 03 28 오후 3 36 58 ...

Page 10: ...ncomplete Packaged DOAS Kit E111 Modbus communication error when COMM KIT cannot receive signals Packaged DOAS Kit Fresh Access Packaged DOAS Controller E162 EEPROM Hardware ERROR Packaged DOAS Kit E202 Packaged DOAS Kit FCU Interface Module MIM F10N communication error 3 min Packaged DOAS Kit or FCU Interface Module SOL Packaged DOAS Kit 북미향 IM_EN_DB68 08395A 00 indd 10 2019 03 28 오후 3 36 58 ...

Page 11: ...itch to 0 and the unit digit to 1 NOTE Packaged DOAS Kit has1 forits Modbus address 0 5 9 4 8 3 7 2 6 1 10 s SW5 0 5 9 4 8 3 7 2 6 1 1 s SW4 The tens digit is set to 0 The unit digit is set to1 C Set the Dip switch settings for baud rate protocols ports and more set the dip switch to off off off off off off off on 2 3 4 5 6 7 8 ON Modbus Baud set to 9600 BAS Port1 IPAddress Enhanced access port D ...

Page 12: ...DB68 08395A 00 SOL Packaged DOAS Kit 북미향 IM_EN_DB68 08395A 00 indd 12 2019 03 28 오후 3 37 00 ...

Reviews: