background image

Wired Remote Control

MWR-TH00
MWR-TH01

DB98-29803A(2)

I

F

S

E

P

G Ne Po Hu

A

R

D

Air Conditioner

user manual

imagine

 the possibilities

Thank you for purchasing this Samsung product. 

29803-2_co.indd   3

2010-09-06   오후 5:11:51

Summary of Contents for MWR-TH01

Page 1: ...Remote Control MWR TH00 MWR TH01 DB98 29803A 2 I F S E P G Ne Po Hu A R D Air Conditioner user manual imagine the possibilities ThankyouforpurchasingthisSamsungproduct 29803 2_co indd 3 2010 09 06 오후 5 11 51 ...

Page 2: ...oller with wet hands Do not install the remote controller in a location where it will come into contact with the combustible gases machine oil sulphide gas etc Do not press buttons with a pointed thing Do not pull or bend the wired remote controller cable excessively Do not use this wired remote controller for other purpose Do not spray an insecticide or other combustible things on the wired remot...

Page 3: ...UTOMATIC OPERATING MODE COOLING YOUR ROOM HEATING YOUR ROOM EXCEPT COOLING ONLY MODELS REMOVING EXCESS HUMIDITY AIRING YOUR ROOM ADJUSTING THE AIR FLOW DIRECTION EXCEPT DUCT TYPE SETTING THE ON TIMER SETTING THE OFF TIMER 4 5 6 8 10 12 14 15 16 18 MWR TH00 IB_E_29803 10 24 08 18 01 Page 3 ...

Page 4: ... you press the button N N N No o o ot t t te e e e Mode selection button Communication error indicator On Timer setting Off Timer setting Test indicator Timer button Timer Set Cancel button Test button Filter Reset button Swing button Except Duct type Temperature adjustment buttons Removing frost indicator Temperature setting Fan speed Air flow direction Filter Sign indicator On Off button Fan spe...

Page 5: ...le information on using your wired remote controller Please take the time to read them as they will help you take full advantage of the unit s features In the manual you will find a series of step by step procedures for each function available The illustrations in the step by step procedures use three different symbols PRESS PUSH HOLD DOWN MWR TH00 IB_E_29803 10 24 08 18 01 Page 5 ...

Page 6: ...mode press the button until is displayed at the top of the wired remote controller Result The air conditioner runs in the AUTO mode 2 The air conditioner is fitted with a protection mechanism to prevent the unit from being damaged when it is started immediately after being Plugged in Stopped lt will start up normally after three minutes IMPORTANT You can change modes at any time N N N No o o ot t ...

Page 7: ...Possible temperatures are between 18 C and 30 C inclusive Result Each time you press buttons The temperature is adjusted by 1 C The air conditioner starts cooling provided that the room temperature is than the selected temperature The quantity of air is adjusted automatically 3 MWR TH00 IB_E_29803 10 24 08 18 01 Page 7 ...

Page 8: ... when cooling To select the COOL mode press the button until is displayed at the top of the wired remote controller Result The air conditioner runs in the COOL mode 2 The air conditioner is fitted with a protection mechanism to prevent the unit from being damaged when it is started immediately after being Plugged in Stopped lt will start up normally after three minutes IMPORTANT You can change mod...

Page 9: ...The temperature is adjusted by 1 C The air conditioner starts cooling provided that the room temperature is higher than the selected temperature the fan will however operate 3 Select the fan speed by pressing the button one or more times until the intended value is displayed 4 To control the direction of the air flow refer to page 15 5 Automatic rotated Low Medium High MWR TH00 IB_E_29803 10 24 08...

Page 10: ...ng To select the HEAT mode press the button until is displayed at the top of the wired remote controller Result The air conditioner runs in HEAT mode 2 The air conditioner is fitted with a protection mechanism to prevent the unit from being damaged when it is started immediately after being Plugged in Stopped lt will start up normally after three minutes IMPORTANT You can change modes at any time ...

Page 11: ...The temperature is adjusted by 1 C The air conditioner starts heating provided that the room temperature is lower than the selected temperature the fan will however operate 3 Select the fan speed by pressing the button one or more times until the intended value is displayed 4 Automatic rotated Low Medium High To control the direction of the air flow refer to page 15 5 MWR TH00 IB_E_29803 10 24 08 ...

Page 12: ... too much To select the DRY mode press the button until is displayed at the top of the wired remote controller Result The air conditioner runs in the DRY mode 2 The air conditioner is fitted with a protection mechanism to prevent the unit from being damaged when it is started immediately after being Plugged in Stopped It will start up normally after three minutes IMPORTANT You can change modes at ...

Page 13: ...e temperatures are between 18 C and 30 C inclusive Result Each time you press buttons The temperature is adjusted by 1 C The air conditioner starts removing the excess humidity The quantity of air is adjusted automatically 3 To control the direction of the air flow refer to page 15 4 MWR TH00 IB_E_29803 10 24 08 18 01 Page 13 ...

Page 14: ...mote controller Result The air conditioner runs in the FAN mode 2 The air conditioner is fitted with a protection mechanism to prevent the unit from being damaged when it is started immediately after being Plugged in Stopped It will start up normally after three minutes IMPORTANT Select the fan speed by pressing the button one or more times until the intended value is displayed 3 To control the di...

Page 15: ...or unit you can adjust the position of the air flow blade thus increasing the efficiency of the air conditioner To stop the blade press the button again To set to the required position press the button again when the blade is in the required position 2 When the air conditioner is first turned on the blade is moved IMPORTANT MWR TH00 IB_E_29803 10 24 08 18 01 Page 15 ...

Page 16: ...e air conditioner is off Press the button to complete the setting Result The remaining time is displayed Blinking of the timer indicator stops The selected mode and the temperature disappear on the display after 5 seconds The air conditioner will switch on automatically when the counter displayed on the remote controller reaches the setting time as disappearing the On timer setting 2 You can see o...

Page 17: ...Press the button 1 To Cancel the On Timer If you want to turn on the air conditioner before the timer reaches the setting time press the button N N N No o o ot t t te e e e MWR TH00 IB_E_29803 10 24 08 18 01 Page 17 ...

Page 18: ...ven period of time You can set the period of time from 30 minutes to 24 hours You can select the Off Timer only when the air conditioner is on Press the button to complete the setting Result The remaining time is displayed Blinking of the timer indicator stops The air conditioner will switch off automatically when the counter displayed on the remote controller reaches the setting time as disappear...

Page 19: ...ress the button 1 To Cancel the Off Timer If you want to turn off the air conditioner before the timer reaches the setting time press the button N N N No o o ot t t te e e e MWR TH00 IB_E_29803 10 24 08 18 01 Page 19 ...

Page 20: ...29803 2_co indd 2 2010 08 30 오후 9 23 25 ...