Printing quality problems
277
6. Troubleshooting
Loose toner
•
Clean the inside of the machine (see "Cleaning the machine" on page 87).
•
Check the paper type and quality.
•
Remove the imaging unit and then, install a new one (see "Replacing the toner cartridge" on page 79).
If the problem persists, the machine may require repair. Contact a service representative.
Character voids
Character voids are white areas within parts of characters that should be solid black:
•
You may be printing on the wrong surface of the paper. Remove the paper and turn it around.
•
The paper may not meet paper specifications.
Horizontal stripes
If horizontally aligned black streaks or smears appear:
•
The imaging unit may be installed improperly. Remove the imaging unit and reinsert it.
•
The imaging unit may be defective. Remove the imaging unit and install a new one (see "Replacing the imaging unit" on page 81).
If the problem persists, the machine may require repairing. Contact a service representative.
Condition
Suggested solutions