background image

2. Installation : Signal B’d Assembly

39

Attaching the Signal Box

Fig.10 Signal Box attachment point

screw

Attach the Bracket Support

Attach the Signal Box

(sliding Board to Bracket, then turn lock)

Open the door on the rear of the cabinet and attach the Signal Box  

(Fig.10).

Summary of Contents for LH080XPRZAS/PZ

Page 1: ...Outdoor LED Installation Manual XPR Series Standard Cabinet LH080XPRZAS PZ Rev 0 9 ...

Page 2: ...iguration Fan installation 2 Installation Overview Unboxing Accessary Assembly Fan Assembly Handling Cabinet Mounting Cabinet Y8 Signal B d Assembly Cable Connections Power Connections Waterproof Bezel Accessary Assembly 3 Accessory Kit Tools Materials 4 Control Room Setting System configuration System Matrix ...

Page 3: ...sure safety Ensure that the power cord is not close to any heat sources The cord sheath may melt and cause a fire or electric shock Do not install the product in a confined space with poor ventilation The internal temperature may increase and cause a fire Make sure you remove the power cord before transporting the product Transporting the product with the cord connected may cause a fire or electri...

Page 4: ...ting object Make sure the LED surface does not face down onto the floor Exercise caution to ensure that the corners of the LED module are not damaged due to contact with external factors Make sure the number of loaded rows does not exceed two Be careful to prevent LED damage due to electric shock Do not touch the LED surface with bare hands without wearing anti static gloves Be careful to prevent ...

Page 5: ...lack Uniformity L10 0 15 TBD Video Processing 24 Bit Color Capacity 16 Bit Color Temp 4 500 9 000K Refresh Rate spec 4 800Hz 7 680Hz 7 680Hz 7 680Hz 7 680Hz Horizontal Viewing Angle 160 Vertical Viewing Angle Top Bottom 20 65 Contrast Ratio 8 000 1 Typ Weight Kg sqm 40 kg IP Rating Front Rear IP67 IP66 EMC Class A Cabinet Material Aluminum Service Front Rear ...

Page 6: ...lack Uniformity L10 0 15 TBD Video Processing 24 Bit Color Capacity 16 Bit Color Temp 4 500 9 000K Refresh Rate spec 4 800Hz 7 680Hz 7 680Hz 7 680Hz 7 680Hz 7 680Hz Horizontal Viewing Angle 160 Vertical Viewing Angle Top Bottom 20 65 Contrast Ratio 8 000 1 Typ Weight Kg sqm 40 kg IP Rating Front Rear IP67 IP65 EMC Class A Cabinet Material Aluminum Service Front Rear ...

Page 7: ... Standard Cabinet Outside 1 Product Information Standard Cabinet 7 Front Rear ...

Page 8: ... Standard Cabinet Product Size 1 Product Information Standard Cabinet 8 Item Spec Cabinet Size W x H 1000 mm x 1000 mm Module Size A x B 250 mm x 250 mm Set depth D 264 3 mm Weight kg 38 kg ...

Page 9: ...Y8 PDS SMPS SMPS SMPS SMPS Standard Cabinet Y8 Product Inside 1 Product Information Standard Cabinet 9 PDS SMPS AC Filter Power In Power Out External Fan position Y8 1 Y8 for 1 block ...

Page 10: ...1 Product Information Package 10 1265 1225 387 Outdoor Cabinet Box Read the label to make sure it is the right cabinet Read the information in the attached label to check the Model Code and Project No ...

Page 11: ...FHD and the size covered by the Y8 T con board FHD Zone 15 x 8 Cabinet configuration which is the maximum configuration that can display content with a resolution of FHD or lower Y8 Block 3 x 4 Cabinet configuration which is the maximum configuration that can be covered by the Y8 board FHD ZONE Y8 Block Cabinet ...

Page 12: ...ion by screen Signal B d Forward Y8 B d Backward Y8 B d The location depends on the cabinet configuration you want to install See LED configurator This zone configuration differs by pitch Note that the zone configuration diagram below is applicable to P8 30m 24m P8 ZONE1 P8 ZONE2 P8 ZONE3 P8 ZONE4 P8 ZONE5 P8 ZONE6 ...

Page 13: ...c control unit of System The location of the Redundancy Signal Board is installed in the cabinet where the data ends XPR060 S XPR060 E Cabinet Configuration 12 x 6 Resolution 1920 x 960 of Y8 12 24 for redundancy of Signal 2 XPR080 S XPR080 E Cabinet Configuration 15 x 8 Resolution 1800 x 960 of Y8 10 20 for redundancy of Signal 2 XPR100 S XPR100 E Cabinet Configuration 20 x 11 Resolution 1920 x 1...

Page 14: ...tion of the Redundancy Signal Board is installed in the cabinet where the data ends XPR160 S XPR160 E Cabinet Configuration 30 x 16 Resolution 1800 x 960 of Y8 12 24 for redundancy of Signal 2 XPR200 E Cabinet Configuration 40 x 20 Resolution 1920 x 960 of Y8 20 40 for redundancy of Signal 4 Serial B d Box 2 Serial server only 2 ...

Page 15: ...location Fan type 2 External fan Intake Exhaust 1 Internal fan Repeat configuration for 5 Cabinet rows as shown below Intake fan Internal fan Exhaust fan Exhaust fan Intake fan Internal fan External Fan Internal Fan 5 Columns Air inlet Air outlet Air inlet Air outlet ...

Page 16: ... Y8 Signal B d Assembly Cable Connection Power Connection Control Room Setting Pre Working Before Cabinet Hang Accessories Assembly SW set up Installation Overview The installation follows the below order Prior to the assembly clearly identify the pre work On site HW Installation On site SW Setup Operation ...

Page 17: ... EXHAUST FAN EXHAUST FAN Y8 Y8 Redundancy INTAKE FAN INTERNAL FA N INTAKE FAN INTERNAL FAN INTAKE FAN INTERNAL FAN Ex Total Screen 3x4 Cabinet 1 Pre Cabinet Installation Accessories EXHAUST FAN INTAKE FAN INTERNAL FAN 2 Installation Accessories After Cabinet installation Y8 Y8 Redundancy SIGNAL B d COVER ACCESSARY BEZEL COVER ACCESSATRY BEZEL ...

Page 18: ... Pre Installation Work All Cabinet Do the following for all cabinets Ex FHD Zone Screen 1 cabinet Work 2 Installation Unboxing Cabinets Accessories ...

Page 19: ... bag Unboxing 2 Installation Unboxing Cabinets Accessories When unboxing the package or moving the product do not hold the handles in the middle of the rear door or the plastic covers on both corners of the top Use Handle when move cabinet Don t hold this plastic part when move cabinet 19 Squeeze the winged handles together and pull them out ...

Page 20: ...e cabinet Unboxing 2 Installation Accessory Assembly Attach the Eye Nut x2 to the brackets at both ends on top of the cabinet Screw point Bolt Ring Ring Eye Nut 1 by 1 installation Every cabinets Section installation Only Top cabinets of Section block 20 ...

Page 21: ... Installation Pre work on ground lowest cabinets P38 Do the following for lowest cabinets Ex FHD Zone Screen 1 cabinet to work on Bolt M8 L18 Attach the Bracket frame bottom L R to the bottom of the cabinet ...

Page 22: ...n on every 5th lines intake Exhaust P23 P24 Ex FHD Zone Screen 1 cabinet to work on Intake Fan Internal Fan Exhaust Fan Exhaust Fan Intake Fan Internal Fan Install every fifth line but if the screen is not a multiple of 5 install it at the top of screen ...

Page 23: ...llation 23 2 Installation Fan Assembly Open the doors 1 Remove the PC sheet 3 Insert the filter Install the fan and the filter without separating it 2 Remove the view 5 Attach the PC sheet x4 to the top of cabinet Only for cabinets where Exhaust Fan is assembled Please distinguish between Intake and Exhaust fan through this attached label Check the location of the cabinet to be installed intake Ex...

Page 24: ...Fan Assembly Open the doors Hook the top of fan on the Bracket support Rear service site Screw M4 L6 1point Front service site Screw M4 L20 2point It depends on whether it is front or rear installation Please refer to the image below ...

Page 25: ...4 P20 0 3 1 0 0 3 1 0 0 4 P6 P8 P10 P16 P20 Used tools Kit box Combination wrenches 13mm 21mm Ratchet with deep socket 13mm 21mm Ratchet with deep socket 13mm 21mm 25 When fixing after hanging the cabinet or making section the workers at the front and back of the cabinet should communicate with each other and install it according to the seam specifications Rear installation M8 BOLT NUT C B N C B N...

Page 26: ...dundant wire Maximum number of cabinets that can be moved when installing a section 4x2 cabinets spreader bar Remove the Eye Bolt after hang a cabinet section on the frame Guide to moving the product using a crane Installing a single cabinet Orient the eye bolt in line with the slings Hole for 2nd wire Installing a section 4X2cabinet ...

Page 27: ...he top and bottom of the two cabinets with bolts C B N C B N Z seam Cabinet to be extended Tighten the two cabinets directly from inside the cabinet with bolts doors open At the same time adjust the Z seam based on the LED modules on the front And repeat the 1stpes up to here about lateral extension M8 L18 BOLT X seam ...

Page 28: ... cabinet below M8 L18 BOLT Lowest of section Y seam Tighten the two cabinets directly from inside the cabinet with bolts doors open At the same time adjust the Z seam based on the LED modules on the front M8 L18 BOLT Cabinet to be extended Cabinet to be extended Repeat steps 1 and 2 for the other three cabinets ...

Page 29: ... cabinet section Z seam Tighten the two cabinets sections directly from inside the cabinet with bolts doors open At the same time adjust the Z seam based on the LED modules on the front M8 L18 BOLT X seam Tighten the brackets against the top and bottom of the two cabinets sections with bolts M8 L18 BOLT M8 L18 BOLT M8 BOLT NUT M8 BOLT NUT Tighten the top every brackets to the L shaped steel assemb...

Page 30: ...ckets on the cabinet below M8 L18 BOLT Upward extension cabinet section cabinet below M8 BOLT NUT M8 BOLT NUT Upward extension cabinet section Y seam Tighten the two cabinets sections directly from inside the cabinet with bolts doors open At the same time adjust the Z seam based on the LED modules on the front M8 L18 BOLT 30 Tighten the top every brackets to the L shaped steel assembled on the H b...

Page 31: ...BOLT Tighten the three cabinets directly from inside the cabinet with bolts doors open At the same time adjust the Z seam based on the LED modules on the front Tighten the bolts between the bottom of the cabinet and the brackets on the cabinet below Tighten the brackets against the top and bottom of the two cabinets sections with bolts Tighten the top every brackets to the L shaped steel assembled...

Page 32: ...BOLT NUT M8 BOLT NUT Hang the Brackets of cabinet section corner on the frame Tighten the top every brackets to the L shaped steel assembled on the H beam Tighten the two cabinets sections directly from inside the cabinet with bolts doors open At the same time adjust the Z seam based on the LED modules And Reassemble the LED modules Tighten the top every brackets to the L shaped steel assembled on...

Page 33: ...LED modules as shown Y seam M8 L18 BOLT 33 M8 BOLT NUT M8 BOLT NUT Tighten the two cabinets section directly from inside the cabinet with bolts doors open At the same time adjust the Z seam based on the LED modules And Reassemble the LED modules Tighten the top every brackets to the L shaped steel assembled on the H beam Upward extension cabinet section ...

Page 34: ...ased on the cabinet below And disassemble some LED modules as shown Tighten the three cabinets sections directly from inside the cabinet with bolts doors open At the same time adjust the Z seam based on the LED modules And Reassemble the LED modules Tighten the top every brackets to the L shaped steel assembled on the H beam Cabinet Section extending sideways and upwards ...

Page 35: ...8 Assembly Y8 Address Setting Signal B d Assembly Cable Connection Y8 to Module Y8 to Y8 PDS to PDS B d ID setting Signal B d to Y8 PDS Power Connection EXHAUST FAN Signal B d EXHAUST FAN EXHAUST FAN Y8 Y8 Redundancy INTAKE FAN INTERNAL FAN INTAKE FAN INTERNAL FAN INTAKE FAN INTERNAL FAN ...

Page 36: ...Assembly 36 9 Open the door on the rear of the cabinet and attach the Y8 board Fig 9 Attaching the Y8 board Fig 9 Y8 Board attachment point Bracket Support assembly Y8 assembly sliding Y8 to Bracket then turn lock screw ...

Page 37: ...rd give the address so that the system can check the Y8 location Refer to the figure below to specify the location by setting the corresponding binary switch Screen Y8 Board 1 Cabinet Y8 Board 000 001 002 003 004 005 006 Ex Address No 001 Ex Address No 002 Ex Address No 015 ...

Page 38: ... 0 0 0 0 002 00000010 0 1 0 0 0 0 0 0 003 00000011 1 1 0 0 0 0 0 0 004 00000100 0 0 1 0 0 0 0 0 005 00000101 1 0 1 0 0 0 0 0 006 00000110 0 1 1 0 0 0 0 0 007 00000111 1 1 1 0 0 0 0 0 008 00001000 0 0 0 1 0 0 0 0 009 00001001 1 0 0 1 0 0 0 0 010 00001010 0 1 0 1 0 0 0 0 011 00001011 1 1 0 1 0 0 0 0 012 00001100 0 0 1 1 0 0 0 0 013 00001101 1 0 1 1 0 0 0 0 014 00001110 0 1 1 1 0 0 0 0 015 00001111 1...

Page 39: ...ly 39 Attaching the Signal Box Fig 10 Signal Box attachment point screw Attach the Bracket Support Attach the Signal Box sliding Board to Bracket then turn lock Open the door on the rear of the cabinet and attach the Signal Box Fig 10 ...

Page 40: ...40 Signal Board Assembly Cap Cable Gland Snap lock pin Optical repeater point Signal Box attachment point Attach the optical repeater Remove the cap and attach the cable gland to the power cable inlet port Fig 11 Connect the power cable ...

Page 41: ...he cover after connecting the data cable Fig 13 Data cable specifications It is necessary to add Teflon tape when using a cable with a circular Φ7 0 8 0mm and Φ7 0mm or less Data cable Connection Fig 12 Power Data cabling point Cover disassemble Cable insert Cover assembly Fig 13 Data cable connection ...

Page 42: ... the data cable connects the following ports P6 Connect 12 ports of the total 16 ports P6 1 2 3 4 5 6 7 8 9 10 11 12 2 x 3 cabinet Y8 B d 2 Installation Cable Connections Y8 to Module 4 ports are not used 1 2 3 4 5 6 7 8 9 10 11 12 ...

Page 43: ...cable connects the following ports P8 10 16 20 Connect 16 ports of the total 16 ports 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 2 Installation Cable Connections Y8 to Module 1 2 3 4 5 6 9 10 11 12 13 14 7 8 15 16 P8 10 16 20 3 x 4 cabinet Y8 B d ...

Page 44: ... Block Configuration Block 3 x 4 Cabinet Y8 Board is able to control upto 12th 3x4 Cabinet Y8 Y8 Y8 Y8 XPR100 S XPR100 E XPR080 S XPR080 E Screen P10 Block Configuration Block 4 x 4 Cabinet is able to control upto 16th 4x4 Cabinet Forward Backward Redundancy Backward Redundancy Forward ...

Page 45: ... Configuration Block 2 x 4 Cabinet Y8 Board is able to control up to 8th 2x4 Cabinet XPR160 S XPR160 E XPR200 E XPR060 S XPR060 E Screen P16 P20 Block Configuration Block 10 x 4 Cabinet Y8 Board is able to control upto 40th 10x4 Cabinet Forward Backward Redundancy Forward Backward Redundancy ...

Page 46: ...le Connection 3x4 Cabinet 1 As shown in the figure below the Y8 board VG XACMBKIT for Forward Path is used for the 1 cabinet of the figure below and the Y8 board for Redundant Path Connect the board VG XACSBKIT to Figure 2 below Refer to the Accessory Assembly Y8 assembly 1 2 ...

Page 47: ...8 Y8 P1 P2 P3 P4 P9 P10 P11 P12 P13 P14 P15 P16 No Cable Label P1 P2 P3 P4 P5 P6 P7 P8 P9 P10 P11 P12 P13 P14 P15 P16 Row1 800mm Row2 500mm Row3 800mm Row4 500mm P1 P16 Forward connection data cable label RP1 RP16 Data cable label for redundancy connection Connect by matching the cable s label number and Y8 s number Connect as shown in the figure on the right by referring to the label of the cable...

Page 48: ...tion diagram of 3x4 cabinet RP1 to PR16 Redundancy connection data cable label No Description RP1 RP2 RP3 RP4 RP5 RP6 RP7 RP8 RP9 RP10 RP11 RP12 RP13 RP14 RP15 RP16 RP1 RP2 RP3 RP4 RP5 RP6 RP7 RP8 RP9 RP11 RP12 RP13 RP14 RP15 RP16 RP10 Connect as shown in the figure on the right by referring to the label of the cable ...

Page 49: ...se cables and to connect data cables between the cabinets Run cables through the waterproof tunnel next to each cabinet Y8 Out in As shown in the picture there is a cabinet in the middle align and connect to Wire Holder The left cabinet is OUT The right cabinet side connects to IN Out in ...

Page 50: ...ons Y8 to Module 50 Data cable Connection 3x4 Cabinet 3 Caution When securing cables exercise caution to ensure that AC lines do not come into contact with data power cables P5 P6 P7 P8 Y8 P1 P2 P3 P4 P9 P10 P11 P12 P13 P14 P15 P16 ...

Page 51: ...5 RP6 RP7 RP8 RP9 RP11 RP12 RP13 RP14 RP15 RP16 RP10 P5 P6 P7 P8 Y8 P1 P2 P3 P4 P9 P10 P11 P12 P13 P14 P15 P16 Data cable Connection 3x4 Cabinet 4 Use cables to to connect Y8 boards to cabinets redundant path connection Connect the cables to OUT on the cabinet modules ...

Page 52: ...llation Cable Connections Y8 to Module 52 Ex If 4 x 2 is left Ex If 3 x 2 is left Note If the layout of connected cabinets is not 3x4 connect cables based on the condition with the bottommost cabinets excluded ...

Page 53: ...ENCM For Y8 boards that send data connect the cables to OUT on the boards For Y8 boards that receive data connect the cables to IN on the boards as shown below TMDS cable OUT IN IN OUT IN OUT IN OUT IN OUT IN OUT IN OUT IN OUT IN OUT IN Install the TMDS holder after connecting to the input port to prevent damage S S OUT ...

Page 54: ...ection Serial connection RJ45 LAN cable VG XACMBKIT ENCM For Y8 boards that send data connect the cables to TX on the boards For Y8 boards that receive data connect the cables to RX on the boards as shown below LAN cable RX TX RX TX RX TX RX TX RX TX RX TX RX TX RX TX RX TX RX TX S ...

Page 55: ... TMDS Cable Connection VG XACMBKIT ENCM For Y8 boards that send data connect the cables to OUT on the boards For Y8 boards that receive data connect the cables to IN on the boards as shown below TMDS cable IN OUT IN OUT IN OUT IN OUT OUT IN Install the TMDS holder after connecting to the input port to prevent damage S S ...

Page 56: ...Connection Serial connection RJ45 LAN cable VG XACMBKIT ENCM For Y8 boards that send data connect the cables to TX on the boards For Y8 boards that receive data connect the cables to RX on the boards as shown below LAN cable TX RX TX RX TX RX TX RX TX RX TX RX TX RX TX RX TX RX S S ...

Page 57: ... data signals are delivered in a single zone the PDS boards connected to the forward specific signal bracket are connected to half of the cabinets Group1 and the PDS boards connected to the backward specific signal bracket are connected to the other half Group2 ZONE Unit Group1 Group2 Start Start ...

Page 58: ...p1 Serial connection RJ45 LAN Cable connection VG XACP8KIT ENCP For PDS boards that send data connect the cables to OUT on the boards For PDS boards that receive data connect the cables to IN on the boards as shown below 1 cabinet OUT IN PDS 1 PDS 2 PDS 1 PDS 2 RJ45 LAN cable ...

Page 59: ...ard Group1 Serial connection RJ45 LAN Cable connection For cabinets connected to Group1 connect LAN cables to OUT on the PDS boards that send data and to IN on the PDS boards that receive data as shown in ZONE Group1 OUT IN OUT IN OUT IN OUT IN OUT IN OUT IN Start End ...

Page 60: ...e first and last PDS boards and specify the MODE ZONE TACT LED On the first PDS board press the Tact switch once to change the state to RED On the last PDS board press the Tact switch twice to change the state to GREEN The middle PDS boards do not require separate setting Middle PDS boards BLUE state by default Start Point Middle End Point PDS Address check Start End ...

Page 61: ...p2 Serial connection RJ45 LAN cable connection VG XACP8KIT ENCP For PDS boards that send data connect the cables to OUT on the boards For PDS boards that receive data connect the cables to IN on the boards as shown below 1 cabinet OUT IN PDS 2 PDS 1 RJ45 LAN cable PDS 2 PDS 1 ...

Page 62: ...ard Group2 Serial connection RJ45 LAN cable connection For cabinets connected to Group1 connect LAN cables to OUT on the PDS boards that send data and to IN on the PDS boards that receive data as shown in ZONE Group2 OUT IN OUT IN OUT IN Start End OUT IN OUT IN OUT IN ...

Page 63: ...e first and last PDS boards and specify the MODE ZONE TACT LED On the first PDS board press the Tact switch once to change the state to RED On the last PDS board press the Tact switch twice to change the state to GREEN The middle PDS boards do not require separate setting Middle PDS boards BLUE state by default Start Point Middle End Point PDS Address check Start End ...

Page 64: ...x Without Signal B d If you do not install Signal B d connect directly from PC box as follows TMDS Cable LAN Cable 1st Y8 Board Notes Serial Server Port Port 1 Y8 connection Port 2 Light Sensor connection Port 3 PDS connection Port 1 Port 2 Port 3 Port 4 IN 1st PDS Board LAN Cable Power Injector INPUT OUTPUT ...

Page 65: ... of the first Serial Server TMDS Cable LAN Cable CAT5 to Serial Adapter 1st Y8 Board 1st Y8 Board Signal Boardt Signal Board AC DC Converter Fiber to LAN Power Injector AC DC Converter AC Junction Phoenix P1 Notes Serial Server Port Port 1 Y8 connection Port 2 Light Sensor connection Port 3 PDS connection DSUB9 to RJ45 Fiber to HDMI 2 Installation Cable Connections Signal B d Y8 PDS Light Sensor ...

Page 66: ...to the IN port of the first PDS board Notes Serial Server Port Port 1 Y8 connection Port 2 Light Sensor connection Port 3 PDS connection Serial Server Signal Board AC DC Converter Fiber to LAN Power Injector AC DC Converter AC Junction Phoenix P3 DSUB9 to RJ45 Fiber to HDMI CAT5 to Serial Adapter 2 Installation Cable Connections Signal B d Y8 PDS Light Sensor ...

Page 67: ...using LAN cables 1st Y8 Board Light Sensor Signal Board Notes Serial Server Port Port 1 Y8 connection Port 2 Light Sensor connection Port 3 PDS connection Power Injector LAN Cable INPUT OUTPUT Serial Server CAT5 to Serial Adapter Signal Board AC DC Converter Fiber to LAN Power Injector AC DC Converter AC Junction Phoenix P2 DSUB9 to RJ45 Fiber to HDMI 2 Installation Cable Connections Signal B d Y8...

Page 68: ...ing more than the allowed number of power connections the power breaker may be lowered or the product may be damaged due to overcurrent The connection must be below the quantity and we are not responsible for any problems that occur in excess of the number of connections Use the label information attached to the back of the product to check the rated power of the product and the rated current valu...

Page 69: ...erproof IP68 two way plug https www amazon com FX Junction Waterproof Connector External dp B07FDKH4G3 ref pd_sbs_60_1 130 6739139 1804662 _encoding UTF8 pd_rd_i B07FDKH4G3 pd_rd_r 93be4196 88a4 49eb b52f 54fa7efd6831 pd_rd_w 5NOWk pd_rd_wg L8FcV pf_rd_p d66372fe 68a6 48a3 90ec 41d7f64212be pf_rd_r XVQ699PGPQJBZXDGMMNW psc 1 refRID XVQ699PGPQJBZXDGMMNW Not Provided by Samsung AC Junction BOX makes...

Page 70: ...move the cap at the bottom of the back of the cabinet and assemble the cable gland between the power cable connections Fig 7 Power connection Fig 7 Power Data cabling position Cap detachment Cable Gland 조립 Fig 8 Power cable connection Example ...

Page 71: ...ce of the cable handle must be assembled in accordance with the connector pin direction In the direction of the arrow on the connector when connecting AC power You have to fit it in You have to push it until it clicks Rotate and disconnect the AC power in the direction indicated by the cable 2 Installation Power Connections ...

Page 72: ...t 1 AC Junction Box No Compone nt type Item type Item name Description Accessory Power cable AC Junction BOX to Cabinet 600mm 3pin 20A AC IN only Accessory Power cable Cabinet to Cabinet 1100mm 3pin 20A Both AC IN OUT Note that AC Junction Board is a separate item using IP68 AWG12 5 6 7 8 The connections 1 and 5 in the distribution unit are located outside the cabinet connecting to inside cabinet ...

Page 73: ...inets does not exceed four 1 2 3 4 The connections 1 and 5 in the distribution unit are located outside the cabinet connecting to inside cabinet 5 6 7 8 Breaker Specification 30A D Type No Component type Item name Description Accessory Power cable AC Junction Box to Cabinet 600mm 3pin 20A AC IN only Accessory Power cable Cabinet to Cabinet 1100mm 3pin 20A Both AC IN OUT Unconnected the AC port mus...

Page 74: ...not exceeded Single cabinet power for P8 1000 W 1 2 3 4 5 6 7 8 Breaker Specification 30A D Type No Component type Item name Description Accessory Power cable AC Junction Box to Cabinet 600mm 3pin 20A AC IN only Accessory Power cable Cabinet to Cabinet 1100mm 3pin 20A Both AC IN OUT The connections 1 and 5 in the distribution unit are located outside the cabinet connecting to inside cabinet Unconn...

Page 75: ...14 15 16 No Component type Item name Description Accessory Power cable AC Junction Box to Cabinet 600mm 3pin 20A AC IN only Accessory Power cable Cabinet to Cabinet 1100mm 3pin 20A Both AC IN OUT The connection between cabinets 1 and 5 9 and 13 through the distribution board should be made from the outside of one cabinet to the inside of the other Breaker type 30 A D Type ...

Page 76: ... doors PDS board Rear of caninet view Internal Fan Connect the Fan cable in the KIT BOX like these pictures ⓧ Intake Fan Exhaust Fan Internal Fan Power is from upper cabinet PDS In the case of a cabinet to which internal fan is connected Internal fan power must be connected to the upper cabinet Please refer to the figure below and connect the power Power Connection ...

Page 77: ...ap rubber Cover Cap plastic Cover Fan Top Cover Fan Bottom PC Cap Sheet PC Bot Sheet PC Handle Sheet Waterproof Accessories Assembly This is the last step in the cabinet installation and install the following accessories on the outermost face of the screen ...

Page 78: ...cation Add accessory quantities to the corner cabinet Waterproof Accessories Assembly This is the last step in the cabinet installation and install the following accessories on the outermost face of the screen Quantity of Materials per 1 Box Assembly of waterproof accessories on the outside of the cabinet located on the outer line of the screen After the cabinet installation hanging different acce...

Page 79: ...Cap plastic Cover Fan Top Cover Fan Bottom PC Cap Sheet PC Bot Sheet PC Bot Sheet Attach sheets to the cabinet from inside The 4 snaps should be assembled Remove sheet Attach the sheet to the location where the cover fan bottom is assembled Rear service Open the doors Front service Disassemble the LED modules for front Rear service Open the doors Front service Disassemble the LED modules for front...

Page 80: ...nd disassemble if other caps are assembled Stick it completely 45 45 Disassemble Rear service Open the doors Front service Disassemble the LED modules for front 80 Attach its from the outside Remove sheets Cover Cap rubber Cover Cap plastic Cover Fan Top Cover Fan Bottom PC Cap Sheet PC Bot Sheet PC handle Sheet Disassemble if other caps are assembled ...

Page 81: ...oles 2 Installation Waterproof Accessories Assembly SCREW M4 L12 rubber BN81 19153A Place it on top of the cabinet from outside to fit the left and right The dug side is left and right Cover Cap rubber Cover Cap plastic Cover Fan Top Cover Fan Bottom PC Cap Sheet PC Bot Sheet PC handle Sheet 2 Phillips screw driver sides of cover then tighten the screws ...

Page 82: ...Cover Cap plastic Cover Fan Top Cover Fan Bottom PC Cap Sheet PC Bot Sheet PC handle Sheet 82 PC Handle Sheet Attach it to the cabinet handle from the outside 2 Installation Waterproof Accessories Assembly Remove sheet ...

Page 83: ...each side of the cabinet are See illustration on right as different 83 Attaching protection frames for the outer cabinets on the screen 2 Installation Protect Frame Assembly Optional Aluminum Black anodizing Frame Top Frame Bottom Frame Left Frame Right Corner Top L Corner Bot L Corner Top R Corner Bot R 2 Phillips screw driver Tool Kit Box x 1 4 Cabinet x 1 4 Cabinet ...

Page 84: ... align it along front surface 4 Keep Frame Bottom flat by pushing up the center area 5 Assembly Frame Bottom to cabinets by 2EA M8L12 Bolt 6 Locate the Cabinet that needed to install Frame Top 7 Attached Frame Top to Top face of cabinet align it along front surface 8 Assembly Frame Bottom to cabinets by 2EA M8L35 Bolt M8L12 M8L35 2 Installation Protect Frame Assembly Optional ...

Page 85: ...et that needed to install Frame Left or Right 2 Assemble Stud pem to that cabinet 3 Attached Frame Left Right to cabinet align it along front surface 4 Assembly Frame Bottom to cabinets by 2EA M4L12 screw 2 Installation Protect Frame Assembly Optional ...

Page 86: ...sion Ex 2x2 cabinet M4L6 1 Install Cover Frame Top Bottom from left to right 2 Install Cover Frame Left Right from bottom to top 3 Use 2EA M4L6 screw to connect between Cover Frame 2 Installation Protect Frame Assembly Optional ...

Page 87: ...e M4 screw Frame Top Bottom at right end Frame Left Right at top end 2 Assemble Bracket Corner to it designed position 3 Fasten M4L6 screw between Bracket Corner and Frame Left Right 4 Fasten M4L12 screw between Bracket Corner and Frame Top Bottom Caution Using incorrect screw may made damage to cabinet 2 Installation Protect Frame Assembly Optional ...

Page 88: ...nstallation tool Combination wrenches 13mm 21mm Ratchet with deep socket 13mm 21mm Level Cordless Drill With 2 Phillips bit 2 Phillips screw driver Flat Head screw driver 10 25mm Adjustable wrench Parts Tether Teflon PTFE tape Gap gauge Wire Strippers Wire Crimpers RJ45 Crimping Tool Wire Cutters Electrical Tape Fish Tape UV Wire Ties AC DC Amp Meter Painter s Tape Channel Lock Pliers AC Junction ...

Page 89: ...hoose one VG XACNBKIT EN Control Main P16 20 VG XABS8KIT EN BRACKET Frame Kit Essential VG XAFN8KIT EN FAN ASSY plastic filter fan Essential VG XACP8KIT EN Power Cable Misc Essential VG XACSBKIT EN Control Redundant P16 20 Optional choose one VG XACRBKIT EN Control Redundant P6 8 10 VG XAPCZKIT EN PC Box Optional VG XALSSKIT EN Light Sensor Optional VG XASBZKIT EN Signal Board Optional VG XASCZKIT...

Page 90: ...9517A BRACKET FRAME BOTTOM LEFT 8EA BN61 16554A BRACKET FRAME BOTTOM RIGHT 8EA BN61 16555A COVER BOTTOM 32EA BN81 19514A COVER TOP 32EA BN81 19513A Bolt M8 L18 32EA BN81 19153A Hex Bolt M8 L30 20EA BN81 19157A T HANDLE HEX TOOL 1EA HEX KEY 1EA CAP PC SHEET 32EA BN81 19162A COVER CAP 32EA BN81 19515A BOTTOM PC SHEET 32EA BN81 19163A COVER CAP RUBBER 40EA BN63 18387A L BRACKET 9EA BN81 19518A M8 BOL...

Page 91: ...y VG XAFAHKIT per 1 set INTAKE FAN 2EA BN81 19505A SCREW M4 L6 4EA BN81 19151A SCREW M4 L20 4EA BN81 19152A EXTERNAL FAN CABLE 1EA BN39 02521A EXHAUST FAN 2EA BN81 19506A FILTER 4EA BN63 19239A INTENAL FAN CABLE 1EA BN81 18715A INTERNAL FAN 2EA BN81 19507A PC SHEET 4EA BN81 19161A ...

Page 92: ...et SCREW M4 L6 3EA BN81 19151A Y8 CONTROL BOARD 1EA BN41 02796A BRACKET SUPPORT 1EA BN61 16680A TMDS HOLDER 1EA BN81 19168A TMDS CABLE 5M 1EA BN81 19536A Assy DATA CABLE 5EA per code 4 Cables BN82 02546A BN82 02547A BN82 02548A BN82 02552A BN82 02553A LAN CABLE 5M 1EA BN81 19537A Power CABLE 1EA BN39 02504A ...

Page 93: ...D 1EA BN41 02796A BRACKET SUPPORT 1EA BN61 16680A TMDS HOLDER 1EA BN81 19168A TMDS CABLE 11M 1EA BN81 18713A Assy DATA CABLE 5EA per code 4 Cables BN82 02546A BN82 02547A BN82 02548A BN82 02552A BN82 02553A LAN CABLE 11M 1EA BN81 18714A Power CABLE 1EA BN39 02504A Control Main accessory VG XACNBKIT per 1 set ...

Page 94: ...1EA BN41 02796A BRACKET SUPPORT 1EA BN61 16680A TMDS HOLDER 1EA BN81 19168A TMDS CABLE 5M 1EA BN81 19536A Assy DATA CABLE 5EA per code 4 Cables BN82 02549A BN82 02550A BN82 02551A BN82 02554A BN82 02555A LAN CABLE 5M 1EA BN81 19537A Power CABLE 1EA BN39 02504A Control Redundant accessory VG XACSBKIT per 1 set ...

Page 95: ...EA BN41 02796A BRACKET SUPPORT 1EA BN61 16680A TMDS HOLDER 1EA BN81 19168A TMDS CABLE 11M 1EA BN81 18713A Assy DATA CABLE 5EA per code 4 Cables BN82 02549A BN82 02550A BN82 02551A BN82 02554A BN82 02555A LAN CABLE 11M 1EA BN81 18714A Power CABLE 1EA BN39 02504A Control Redundant accessory VG XACRBKIT per 1 set ...

Page 96: ...MASTER POWER CABLE 2EA BN39 02536A LAN CABLE 8EA BN81 18712A DATA CABLE 8 8EA BN82 02556A BN82 02557A CAP PC SHEET 8EA BN81 19162A COVER CAP 8EA BN63 18341A BN63 18398A HANDLE PC SHEET 4EA BN81 19164A Bolt M8 L18 32EA BN81 19153A COVER CAP RUBBER 4EA BN63 18387A L BRACKET 10EA BN81 19167A M8 BOLT NUT 16EA BN81 19158A END CAP 2EA BN81 19336A ...

Page 97: ...8A COVER FRAME RIGHT 4EA BN81 19509A GUIDE PIN 8EA BN81 19171A L BRACKET 10EA BN81 19522A M8 BOLT NUT 16EA BN81 19158A BACKET CORNER BOT LEFT 1EA BN81 19512A BACKET CORNER BOT RIGHT 1EA BN81 19512A BACKET CORNER TOP LEFT 1EA BN81 19512A BACKET CORNER TOP RIGHT 1EA BN81 19512A SCREW M4 L6 20EA BN81 19169A SCREW M4 L12 22EA BN81 19170A ...

Page 98: ...arate purchase item 3 Accessory Kit 98 Protection Frame VG XAFH4KIT per 1 set COVER FRAME BOT 4EA BN81 19511A COVER FRAME TOP 4EA BN81 19510A Bolt M8 L35 8EA BN81 19172A Bolt M8 L12 8EA BN81 19173A SCREW M4 L6 20EA BN81 19169A ...

Page 99: ...sory VG XASBKIT per 1 set 5 volt PSU BN81 17909A 12 volt PSU BN81 17910A LAN Cable Serial Server 1EA BN81 19180A 3M Fiber Jumper 2EA BN81 13643A Serial Adapter 4EA BN81 13912A HDMI Fiber Receiver 1EA BN81 17558A 1M Fiber Jumper 2EA BN81 13642A Ethernet Media Converter 2EA BN81 15094A ...

Page 100: ...rial Server 1EA BN81 19180A 3M Fiber Jumper 2EA BN81 13643A 5 volt PSU 1EA BN81 17909A Serial Adapter 4EA BN81 13912A 12 volt PSU 1EA BN81 17910A LAN Cable 1M Fiber Jumper 2EA BN81 13642A Fiber Enclosure L Com enclosure Ethernet Media Converter 2EA BN81 15094A HDMI Fiber Receiver 1EA BN81 17558A Final assembly ...

Page 101: ...iBase AGS PC 1EA BN81 17540A DisplayPort to VGA 1EA BN81 13793A Monitor 7 1EA BN81 13838A Windows 10 LTSB 1EA BN81 15702A Power Injector 1EA BN94 13069A 12 volt PSU BN81 17910A LAN Cable RJ45 to DB9 Serial adapter 4EA BN81 13912A Fiber Enclosure L Com enclosure 12 volt PSU 1EA BN81 17910A Final assembly ...

Page 102: ...e Control room This refers to a room where you can control and monitor the screen when installing a sports space or a large outdoor screen If control room is provided installation can be done using Signal Box If the control room is not available such as on the highway install it using the PC Box However only screens with resolution below FHD can be installed 102 ...

Page 103: ... Control PC Internet 4k Media Player Data Path Y8 Board Power Distribution LED SCREEN Control Room TMDS MC Fiber MC TMDS MC Fiber MC Signal Bd TMDS MC Fiber MC TMDS MC Fiber MC TMDS Cable LAN Cable Optical Cable Power Cable ETH1 ETH2 ETH1 ETH2 Ethernet Switch PDS Board FBR Fiber MC Media Converter Optical Signal Bd ...

Page 104: ...etting System Configuration Without Control room 104 Total system configuration Without Control room LED Control PC Internet Y8 Board LED SCREEN PC BOX TMDS Cable LAN Cable Power Cable Serial Server Power Distribution ...

Page 105: ...trol room LED SCREEN LED Control PC Internet Y8 Board LED SCREEN PC BOX TMDS Cable LAN Cable Power Cable Power Distribution LED Control PC LCD Monotor PDS Board Y8 Board PDS Board HDMI Distributor LAN Cable Backward LAN Cable Backward HDMI Cable Forward LAN Cable Forward LAN Cable Forward HDMI Cable Backward ...

Page 106: ...the System Matrix PV System and Processor Please contact SI for further information regarding use and connection LED Control PC Internet 4k Media Player Data Path TMDS MC FBR MC TMDS MC FBR MC ETH1 ETH2 ETH1 ETH2 Control Room 4 Control Room Setting ...

Page 107: ...trol PC to enable a connection with the Serial Server Next in the Internet Explorer address bar enter the Serial Server IP address to access the settings screen Click the Login button You do not need to enter a password Control PC IP settings screen example The default static IP address for the Serial Server can be found in the label on the rear ...

Page 108: ...08 Serial Server Setting Configure settings for each port ports 1 to 4 as shown below Mode RS 422 4 wire Baud Rate 115200 Press Save The Serial Server automatically reboots The reboot process takes about 15 seconds to complete ...

Page 109: ...displays With this software you can control multiple displays of different sizes and pixel pitches Use the Setup System Matrix 20 04 0802x64 msi file to install the System Matrix software After the software is installed the software shortcut appears on the Start menu To launch the software select Start All Programs Prismview System Matrix ...

Page 110: ... 110 System Matrix program setting Set the value for the XPR model on the Settings Output Settings screen of the main screen When connecting to Redundant Y8 board Choose Dual Interface and change the Redundant Y8 board DIP Switch DUAL ON ...

Page 111: ...ion set Country Region City to suit the installation location Normally set to automatically adjust the brightness according to the Sunrise Sunset time Latitude Longitude is automatically specified according to the selected region Ramp time allows gradual change in brightness adjustment according to Sunrise Sunset ...

Page 112: ...4 Control Room Setting System Matrix 112 System Matrix program setting Add the Controllers and Displays you want to control from the menu Manage Systems at the top of the main screen ...

Page 113: ...g Connect the added controller and display to each other Click and drag the mouse over the Display Area while you click on the appropriate Controller Area After confirmation of link click Save Exit Controller Display non connection the pop up window below appears linked ...

Page 114: ...4 Control Room Setting System Matrix System Matrix program setting The Controller window appears and for detailed setup click the Setting button 114 ...

Page 115: ...m Setting System Matrix 115 System Matrix program setting Click the configure output layout button the Layout button to set the value for the associated screen layout example Configure 2x2 Cabinet screens with 2 Y8 ...

Page 116: ...trix 116 Number of connected PDS Master Y8 Redundant Y8 Light Sensor PDS System Matrix program setting On the Communications Settings screen enter the Serial Server connection information Connected Serial Server IP address insert Port ...

Page 117: ...Screen output control simple screen brightness control Use for troubleshooting purposes such as print test pattern and video signal color uniformity etc Schedule the video contents Power supply status check Pixel Module Y8 status monitor product temperature PDS diagnostics control settings Dimming Global Control Serial Colors Global Setting Diagnostics Power Status ...

Page 118: ...3 General Output Output Enter the desired default brightness value as a percentage in the General Output field at the top center of the window The display brightness is set to this setting when the program reboots Use Ramping function Dynamic brightness adjustment activated If you check this function the brightness will be automatically adjusted based on the criteria below Value of Minimum Maximum...

Page 119: ...ling the Light Sensor and entering the Day Lumens Night Lumens value When enabled the light sensor automatically controls the brightness Use Global Sensor If you check this function you can adjust the brightness of all displays connected to System Matrix with one light sensor at a time Day Lumens Specify the brightness Threshold value or Max output value for the daytime zone If the Light Sensor va...

Page 120: ...imum brightness value of the desired display to Min Set the minimum brightness value for the desired display to If you want to use Dynamic brightness mini max level you should check Use ramping box 2 Dimming menu Select Dimming from the drop down menu in the upper left corner of the Setting window 1 Open Setting window Click the Settings button in the main window of the program ...

Page 121: ...After checking Enable press the right button to modify the Dimming Schedule file The Dimming Schedule is created as a text file based on HTML code After modification the Save Exit button must be pressed to reflect example 2 Dimming menu Select Dimming from the drop down menu in the upper left corner of the Setting window 1 Open Setting window Click the Settings button in the main window of the pro...

Page 122: ...4 Control Room Setting System Matrix 122 1 2 3 System Matrix basic function Global Control Serial Colors Global Settings Diagnostics 4 ...

Page 123: ...indow 2 Blank Output Click the Disable Output button in the Global Control window to stop the image output signal To print the image again click the Enable Output button Blanking This function allows you to stop the display s screen output without turning off the set power This means that the user can temporarily dim all displays and output them again while power is being applied ...

Page 124: ...brightness of the display to the desired value When the program restarts the Display will return to the default brightness setting 4 Brightness Adjustment Use the Brightness slider bar to control global brightness Each mark on the slider bar represents a 5 change in display brightness The left side of the bar is 0 and the right side is 100 The Set Brightness XX button applies the slider bar values...

Page 125: ... programwindow 2 Serial Color Test Patterns output The left side of the Serial Color Control window displays a list of connected devices The checkbox allows you to output a specific pattern on the selected device The Output percentage setting allows you to adjust the brightness of the selected display test pattern This setting is output independent of individual or full brightness setting values i...

Page 126: ...6 System Matrix basic function Global Setting Blanking Schedule The function allows you to stop the display output at the specified time zone between the first and second designated time This feature stops display output at any time of night ...

Page 127: ...nable monitoring and diagnosis of product status Data about the power supply status each pixel module Y8 status and PDS diagnostic functions are displayed and the temperature of the product can also be monitored 1 Open Diagnostics window Click the Diagnostics button on the System Matrix main window ...

Page 128: ...4 Control Room Setting System Matrix 128 System Matrix basic function Diagnostics Module 진단 상태 확인 ...

Page 129: ...oom Setting System Matrix 129 System Matrix basic function Diagnostics Check the Module F W Version Check the Y8 F W Version Check the Module Temperature When you check Show problems detail information are appear ...

Page 130: ...4 Control Room Setting System Matrix 130 System Matrix basic function Power Status PDS diagnostics 1 PDS Diagnostics function Double click on the Power Status area of the System Matrix main window ...

Page 131: ... 131 System Matrix basic function Power Status PDS Diagnostics You can monitor ID F W version FAN status temperature Y8 module status of PDS and perform FAN on off Y8 on off module on off and F W update functions through Commands function ...

Page 132: ...Setting System Matrix 132 System Matrix basic function Power Status PDS Control 2 PDS Control function Commands You can select Fan Control to adjust Top Rear Fan On Off and Speed Stage 2 Fan Speed Adjustment Low High ...

Page 133: ...ction Power Status PDS Control 2 PDS Control function Commands You can select Auto Manual mode by selecting Control Mode Auto Mode for automatically adjusting Fan speed according to reference temperature Manual Manually adjust the Fan speed to a user specified speed ...

Page 134: ... Control Room Setting System Matrix 134 System Matrix basic function Power Status PDS Control 2 PDS Control Function Commands You can update the PDS firmware by selecting Update Firmware L XPRMWWAC srec ...

Reviews: