Configuring the Switch
3-130
3
Current Status:
•
Link Status
– Indicates if the link is up or down.
•
Port Operation Status
– Provides detailed information on port state.
(Displayed only when the link is up.)
•
Operation Speed-duplex
– Shows the current speed and duplex mode.
•
Flow Control Type
– Indicates the type of flow control currently in use.
(IEEE 802.3x, Back-Pressure or none)
CLI
– This example shows the connection status for Port 5.
Configuring Interface Connections
You can use the Port Configuration or Trunk Configuration page to enable/disable an
interface, set auto-negotiation and the interface capabilities to advertise, or manually
fix the speed, duplex mode, and flow control.
Command Usage
• Auto-negotiation must be disabled before you can configure or force the interface
to use the Speed/Duplex Mode or Flow Control options.
• When using auto-negotiation, the optimal settings will be negotiated between the
link partners based on their advertised capabilities. To set the speed, duplex mode,
or flow control under auto-negotiation, the required operation modes must be
specified in the capabilities list for an interface.
• The 1000BASE-T standard does not support forced mode. Auto-negotiation
should always be used to establish a connection over any 1000BASE-T port or
Console#show interfaces status ethernet 1/5
Information of Eth 1/5
Basic Information:
Port Type: 100TX
Mac Address: 00-16-B6-F0-71-41
Configuration:
Name:
Port Admin: Up
Speed-duplex: Auto
Capabilities: 10half, 10full, 100half, 100full
Broadcast Storm: Enabled
Broadcast Storm Limit: 64 Kbits/second
Multicast Storm: Disabled
Multicast Storm Limit: 64 Kbits/second
UnknownUnicast Storm: Disabled
UnknownUnicast Storm Limit: 64 Kbits/second
Flow Control: Disabled
LACP: Disabled
Port Security: Disabled
Max MAC Count: 0
Port Security Action: None
Media Type: None
Giga PHY mode: Auto preferred master
Current Status:
Link Status: Down
Operation Speed-duplex: 10half
Flow Control Type: None
Console#
Summary of Contents for iES4028F
Page 1: ...iES4028F 4028FP 4024GP ...
Page 4: ...iv This page is intentionally left blank ...
Page 10: ...x This page is intentionally left blank ...
Page 28: ...Contents xxviii This page is intentionally left blank ...
Page 32: ...Tables xxxii This page is intentionally left blank ...
Page 46: ...Introduction 1 10 1 This page is intentionally left blank ...
Page 336: ...Configuring the Switch 3 280 3 This page is intentionally left blank ...
Page 688: ...Command Line Interface 4 352 4 This page is intentionally left blank ...
Page 702: ...Glossary Glossary 8 This page is intentionally left blank ...
Page 710: ...Index 8 Index This page is intentionally left blank ...
Page 711: ...This page is intentionally left blank ...
Page 712: ...iES4028F 4028FP 4024GP ...