iDCS 500 Release 2 / OfficeServ
INSTALLATION
TECHNICAL MANUAL
PART 3 MARCH 2004
3.18
MGI 2 LED Indication after booting:
RUN
ON ON
PWR
TX
OFF OFF
RX
SRV
ON OFF
DSP
IPC
OFF OFF
MOD
3.30 MEDIA GATEWAY INTERFACE 3 (MGI3)
The card has eight (8) LEDs on its faceplate to indicate the status of the card. These
indications are described below. Insert the card into any universal card slot.
Push firmly in the middle of both card ejectors to ensure the card is firmly seated
into the back plane connector.
LED Name
Function
Status
PWR
Displays the operational status of the MGI
card.
•
Blinking : The MGI card is
operating.
•
Off : The MGI card is not
normally operating
RUN
Displays the power status.
•
On: Power to the MGI
card.
•
Off: No power to the MGI
card
RX
Displays reception of data through an
Ethernet connection.
•
Blinking: Data is being
received.
•
Off: Data is not being
received. After initialization
is complete.
TX
Displays transmission of data through an
Ethernet connection.
•
Blinking: Data is being
transmitted.
•
Off: Data is not being
transmitted.
SRV
Displays if card is in service.
•
On: Service is available.
•
Blinking: Program is being
modified or configuration
is being downloaded.
•
Off: Service is not
available.