iDCS 500 Release 2 / OfficeServ
INSTALLATION
TECHNICAL MANUAL
PART 3 MARCH 2004
3.16
NOTES:
1.
If a cabinet is equipped with a single power supply unit (PSU-60B), a maximum
of 56 station devices may be connected to that cabinet. However, if the cabinet
is equipped with two power supply units, a maximum of 120 station devices may
be connected to that cabinet.
See the configuration section of the General
Description Section for more details.
2. Do not install more than one WLI card in any system.
Note before installing this card it should be correctly configured with the appropriate
drive, and the appropriate number of voice processing modules. One additional Voice
Processing Module can be added to the SVMi-8 to upgrade from 4 to 8 ports, and two
additional Voice Processing Modules can be added to the SVMi-16E to upgrade from 8
to 12, and from 12 to 16 ports.
The SVMi-8/SVMi-16E card is installed in any universal slot of any cabinet. Only one
SVMi-8 can be installed in a iDCS 500 system and it counts as eight (8) stations of the
power supply rating. Only one SVMi-16E can be installed in an iDCS 500 system as
well, but the Station Equivalent Power Units (SEPU) are as follows: an SVMi-16E with 8
ports = 8 SEPU, with 12 ports = 10 SEPU, and with 16 ports = 12 SEPU. Check that
the cabinet power switch is in the OFF position. Next, position the SVMi-8/SVMi-16E
card in the grooves of the card guide and gently slide the card in until it makes contact
with the connector. Press gently but firmly on the top and bottom of the front edge of
the card until the card sits in its connector. Ensure that you have installed the correct
power supply.
3.29 MEDIA GATEWAY INTERFACE 2 (MGI2)
There are no options to select on the MGI2 card. The card has eight (8) LEDs on its
faceplate to indicate the status of the card. These indications are described below.
Insert the card into any universal card slot.
Push firmly in the middle of
both card ejectors to ensure the card is firmly seated into the back plane connector.
RUN
LED 1
LED 2
PWR
TX
LED 3
LED 4
RX
SRV
LED 5
LED 6
DSP
IPC
LED 7
LED 7
MOD
MGI 2 LED Status Indications:
LED Name
Function
Status
PWR
Displays the operational status of
the MGI card
•
Blinking: The MGI card is
operating.
•
Off: The MGI card is not normally
operating
Home Page