background image

FIGURE 6-7

ATTACHING 24B/12B TO 64BM

FIGURE 6–7

iDCS 500 Release 2 / OfficeServ

INSTALLATION

TECHNICAL MANUAL

PART 6   MARCH   2004

M

E

T

A

L

 

C

O

N

N

E

C

T

O

R

 

C

L

IP

2

4

B

 /

 1

2

B

 U

LT

R

A

 B

A

S

E

 W

E

D

G

E

6

4

B

M

 U

LT

R

A

 B

A

S

E

 W

E

D

G

E

G

R

O

O

V

E

 F

O

R

A

D

D

IT

IO

N

A

L

 

C

O

N

N

E

C

T

O

R

C

L

IP

Home Page

Table of Contents

Summary of Contents for iDCS 500

Page 1: ...ADDING AN iDCS 500 EXPANSION CABINET 2 4 2 6 RACK MOUNTING AN iDCS 500 CABINET 2 4 2 7 GROUNDING 2 5 2 8 POWER CONNECTIONS 2 7 2 9 MDF CABLING 2 8 3 INSTALLING PRINTED CIRCUIT CARDS 3 1 MCP2 CARD 3 1...

Page 2: ...D 3 16 3 29 MEDIA GATEWAY INTERFACE 2 3 16 3 30 MEDIA GATEWAY INTERFACE 3 3 18 3 31 E911 CARD 3 19 4 POWER UP PROCEDURES 4 1 DETERMINING POWER SUPPLY 4 1 4 2 CONNECT POWER TO THE SYSTEM 4 2 4 3 PROCES...

Page 3: ...N MODULES 6 3 6 8 ATTACHING DCS 32 BUTTON AOM AND DCS 64 BUTTON MODULES WITH MASTER STATION 6 4 6 9 ATTACHING iDCS 64 BUTTON MODULES TO AN iDCS KEYSET 6 4 6 10 ATTACHING iDCS 14 BUTTON MODULES TO AN i...

Page 4: ...KDBS 8 2 9 SOFTWARE AND DATABASE MANAGEMENT 9 1 9 1 SOFTWARE MANAGEMENT 9 1 9 2 DATABASE MANAGEMENT 9 1 10 ADDING CARDS TO THE SYSTEM 10 1 ADDING STATION AND TRUNKS 10 1 10 2 GRADING THE iDCS 500 FOR...

Page 5: ...that could adversely affect system operation Ensure that all wires and cables going to and coming from the iDCS 500 are properly routed Do not cross fluorescent lights or run parallel with AC wires T...

Page 6: ...KEY SERVICE UNIT DIMENSIONS FIGURE 1 1 iDCS 500 Release 2 OfficeServ INSTALLATION TECHNICAL MANUAL PART 1 MARCH 2004 19 76 22 32 11 81 59 28 39 52 Home Page Table of Contents...

Page 7: ...includes the following items z iDCS 500 Cabinet z Top cover Left and right side covers Front cover Cabinet leg mounting kit AC power and DC power cables Check to see that all additional 500 hardware...

Page 8: ...desired location The final step in installing the cabinet is installing the required PSU60B MCP2 iDCS 500 Main Control Processor with SmartMedia card station and or trunk cards and MDF cables See sect...

Page 9: ...t leg mounting kit AC power and DC power cables Check to see that all additional 500 hardware and software is available for installation at this time Floor mounting equipment legs or castors Cards req...

Page 10: ...o Cabinet Installation Part 2 4 three cabinet installation or Part 2 6 Rack Mounting a Cabinet 4 Insert the PSU60B LCP2 and additional cards in the added cabinet 5 Connect CIC cable assembly to the LC...

Page 11: ...or is to be connected to ground at the service equipment The attachment plug receptacles in the vicinity of the product or system are all to be of a grounding type and the equipment grounding conducto...

Page 12: ...plug the power cord from the AC outlet before attempting to connect the ground Hazardous voltage may cause death or injury Observe extreme caution when working with AC power Remove champ connectors fr...

Page 13: ...T PSU60B The iDCS 500 PSU60B is the power supply for the iDCS 500 cabinet s see Figure 2 6 A second PSU60B or a PSU60 is required if more than 56 stations are installed in a cabinet This same rule app...

Page 14: ...e will result if polarity is reversed Do not connect external AC or DC power to the System see Section 4 Power Up Procedures 2 9 MDF CABLING All connections to the iDCS 500 system are made by way of a...

Page 15: ...TING iDCS 500 Release 2 OfficeServ INSTALLATION TECHNICAL MANUAL PART 2 MARCH 2004 FIGURE 2 1 16 Two 10 screws in 5 8 plywood backboard NOTE Leave screws approximately 1 8 proud of backboard Home Page...

Page 16: ...ATTACHING LEGS TO MAIN CABINET FIGURE 2 2 iDCS 500 Release 2 OfficeServ INSTALLATION TECHNICAL MANUAL PART 2 MARCH 2004 MOUNTING SCREWS FRONT LEFT SIDE BOTTOM Home Page Table of Contents...

Page 17: ...SYSTEM GROUNDING iDCS 500 Release 2 OfficeServ INSTALLATION TECHNICAL MANUAL PART 2 MARCH 2004 FIGURE 2 3 GROUND BAR LEFT SIDE OF CABINET Home Page Table of Contents...

Page 18: ...iDCS 500 POWER INPUT LOCATION iDCS 500 Release 2 OfficeServ INSTALLATION TECHNICAL MANUAL PART 2 MARCH 2004 FIGURE 2 4 Power Input Location Home Page Table of Contents...

Page 19: ...SLOT4 SLOT5 SLOT6 SLOT7 SLOT8 SLOT9 SCP MCP LCP PSU B PSU60 C3 S1 LCP P W R B A T T PSU B SLOT1 SLOT2 SLOT3 SLOT4 SLOT5 SLOT6 SLOT7 SLOT8 SLOT9 SCP MCP LCP PSU B PSU60 PSU B SLOT1 SLOT2 SLOT3 SLOT4 S...

Page 20: ...SETTING VOLTAGE ON PSU 60 AND PSU 60B FIGURE 2 6 110 VOLTAGE SETTING FUSES iDCS 500 Release 2 OfficeServ INSTALLATION TECHNICAL MANUAL PART 2 MARCH 2004 Home Page Table of Contents...

Page 21: ...fficeServ INSTALLATION TECHNICAL MANUAL PART 2 MARCH 2004 FIGURE 2 7 12V 12V 12V 12V 6V 6V 6V 6V 6V 6V 6V 6V OPTION A OPTION B BATTERIES SHOULD BE PLACED WITHIN THREE FEET OF KSU CONNECT TO EITHER A O...

Page 22: ...IDE COVER MOUNTING BRACKETS iDCS 500 Release 2 OfficeServ INSTALLATION TECHNICAL MANUAL PART 2 MARCH 2004 FIGURE 2 8 Bracket Bracket Screws Bracket Bracket Screws Ground Bar Home Page Table of Content...

Page 23: ...SECURING CABINET IN A RACK iDCS 500 Release 2 OfficeServ INSTALLATION TECHNICAL MANUAL PART 2 MARCH 2004 FIGURE 2 9 Mounting Screw Holes Mounting Screw Holes Home Page Table of Contents...

Page 24: ...Backup On Off Switch SmartMedia card slot 12 LED s 3 daughter board positions one with external connections to support a MISC MOH Internal Melody 2 SIO circuits 10 100 Base T LAN connection 12 LED s...

Page 25: ...o link from the SCP2 card ON indicates that the link from the SCP2 card is being set up Flicker indicates a message has been transmitted S4 LCP1 HDLC RX Receive Status OFF indicates that there is no l...

Page 26: ...F receivers MFM 12 DTMF receivers RCM 14 CID receivers ESM Increases the system to 1024 time slots This board is required for multiple cabinet systems MAIN CONTROL PROCESSOR MCP2 DAUGHTER BOARD CAPABI...

Page 27: ...F Holland OFF ON ON ON Denmark z Switch 5 reserved z These DIP switches will not take effect unless the switches are set in the wanted position and the system memory is cleared manually by using the M...

Page 28: ...aughter board may be installed on any processor card Only an SCM or MFM can be installed on the SCP2 not both NOTE Do not insert this card with system power ON There are 12 LED indicators on the front...

Page 29: ...r Connect the iDCS 500 Cabinet Interconnection Connection cable CIC to the front of the LCP2 Connect the opposite end of the CIC to the connector on the front of the MCP2 Connect the second CIC in a s...

Page 30: ...If the system is running L version software the MISC board must be installed in position SCP2 D2 of the SCP2 card see Figure 3 3 or position LCP2 D2 of the LCP2 cards Up to 3 MISC boards can be instal...

Page 31: ...gether see Figure 3 7 or remove the 4 screws holding the SCP2 case together see Figure 3 9 and separate the two halves of the case Place the MFM board face down over the two connectors taking care to...

Page 32: ...to seat it and secure the board with the two screws 3 11 TRUNK B CARD see Figure 3 17 This card has no selectable options Insert as many Trunk B cards as are needed into any universal slots see Figur...

Page 33: ...net is equipped with a single power supply unit PSU 60B a maximum of 56 station devices may be connected to that cabinet However if the cabinet is equipped with two power supply units a maximum of 120...

Page 34: ...he middle of both card ejectors on each card to ensure that it is fully inserted into the back plane connector This card automatically detects DTMF or dial pulse signals from the SLT Software and hard...

Page 35: ...e Figure 3 24 for DIP switch locations Once the DIP switches have been correctly set insert the card into any universal slot See Figure 3 1 Push firmly in the middle of both card ejectors on each card...

Page 36: ...fic a MFM daughter board or boards should be added to a processor card or cards to relieve congestion NOTES 1 If a cabinet is equipped with a single power supply unit PSU 60B a maximum of 56 station d...

Page 37: ...ase by removing the 4 screws see Figure 3 12 and splitting the case The PRI supports NI1 NI2 AT T No 5 ESS and DMS 100 offices A maximum of 9 TEPRI cards can be provided per system 3 per cabinet unles...

Page 38: ...AUTO ATTENDANT CARD see Figure 3 19 This card has no selectable options but is under software control Insert up to and including five AA cards into any universal card slots see Figure 3 1 Push firmly...

Page 39: ...pply rating Only one SVMi 16E can be installed in an iDCS 500 system as well but the Station Equivalent Power Units SEPU are as follows an SVMi 16E with 8 ports 8 SEPU with 12 ports 10 SEPU and with 1...

Page 40: ...if card is in service On Service is available Blinking Program is being modified or configuration is being downloaded Off Service is not available DSP Displays if the DSP channel are being used Off Al...

Page 41: ...LED Name Function Status PWR Displays the operational status of the MGI card Blinking The MGI card is operating Off The MGI card is not normally operating RUN Displays the power status On Power to th...

Page 42: ...f IPC is not in normal a status MOD Displays the operation status of the MGI card OFF The card has booted and is operating normally ON The card is not normally on line MGI 3 LED indication after booti...

Page 43: ...4 3 20 LED Name Function Status ST Card Status Green OK Off Card Not Ready AL Card Alarm Status Off OK On Call In Progress L1 Trunk 1 Status Off Idle L2 Trunk 2 Status Red Trouble L3 Trunk 3 Status Gr...

Page 44: ...OT1 SLOT2 SLOT3 SLOT4 SLOT5 SLOT6 SLOT7 SLOT8 SLOT9 SCP MCP LCP PSU B PSU60 PSU B SLOT1 SLOT2 SLOT3 SLOT4 SLOT5 SLOT6 SLOT7 SLOT8 SLOT9 SCP MCP LCP PSU B PSU60 PSU B SLOT1 SLOT2 SLOT3 SLOT4 SLOT5 SLOT...

Page 45: ...MCP2 CARD FIGURE 3 2 iDCS 500 Release 2 OfficeServ INSTALLATION TECHNICAL MANUAL PART 3 MARCH 2004 Memory Backup Switch Smart Media Home Page Table of Contents...

Page 46: ...SCP CARD FIGURE 3 3 iDCS 500 Release 2 OfficeServ INSTALLATION TECHNICAL MANUAL PART 3 MARCH 2004 Home Page Table of Contents...

Page 47: ...LCP CARD FIGURE 3 4 iDCS 500 Release 2 OfficeServ INSTALLATION TECHNICAL MANUAL PART 3 MARCH 2004 Home Page Table of Contents...

Page 48: ...ESM BOARD FIGURE 3 5 iDCS 500 Release 2 OfficeServ INSTALLATION TECHNICAL MANUAL PART 3 MARCH 2004 Home Page Table of Contents...

Page 49: ...MCP CARD FIGURE 3 6 iDCS 500 Release 2 OfficeServ INSTALLATION TECHNICAL MANUAL PART 3 MARCH 2004 MCP D3 Home Page Table of Contents...

Page 50: ...PROCESSOR CARD SCREW LOCATION FIGURE 3 7 iDCS 500 Release 2 OfficeServ INSTALLATION TECHNICAL MANUAL PART 3 MARCH 2004 Screw Locations Home Page Table of Contents...

Page 51: ...MISC BOARD FIGURE 3 8 iDCS 500 Release 2 OfficeServ INSTALLATION TECHNICAL MANUAL PART 3 MARCH 2004 Home Page Table of Contents...

Page 52: ...SCP CARD SCREW LOCATION FIGURE 3 9 iDCS 500 Release 2 OfficeServ INSTALLATION TECHNICAL MANUAL PART 3 MARCH 2004 Screw Locations Home Page Table of Contents...

Page 53: ...SCM BOARD FIGURE 3 10 iDCS 500 Release 2 OfficeServ INSTALLATION TECHNICAL MANUAL PART 3 MARCH 2004 Home Page Table of Contents...

Page 54: ...MFM BOARD FIGURE 3 11 iDCS 500 Release 2 OfficeServ INSTALLATION TECHNICAL MANUAL PART 3 MARCH 2004 Home Page Table of Contents...

Page 55: ...FIGURE 3 12 SCREW LOCATION iDCS 500 Release 2 OfficeServ INSTALLATION TECHNICAL MANUAL PART 3 MARCH 2004 EJECTOR TABS SCREWS Home Page Table of Contents...

Page 56: ...RCM BOARD FIGURE 3 13 iDCS 500 Release 2 OfficeServ INSTALLATION TECHNICAL MANUAL PART 3 MARCH 2004 Home Page Table of Contents...

Page 57: ...MODEM BOARD FIGURE 3 14 iDCS 500 Release 2 OfficeServ INSTALLATION TECHNICAL MANUAL PART 3 MARCH 2004 Home Page Table of Contents...

Page 58: ...OM BOARD FIGURE 3 15 iDCS 500 Release 2 OfficeServ INSTALLATION TECHNICAL MANUAL PART 3 MARCH 2004 Mounting Screws Line up holes when installing modem Mounting Screws MODEM Home Page Table of Contents...

Page 59: ...A T T SIO1 SIO2 SIO3 SIO4 LAN PSU B SLOT1 SLOT2 SLOT3 SLOT4 SLOT5 SLOT6 SLOT7 SLOT8 SLOT9 SCP MCP LCP PSU B PSU60 PSU B SLOT1 SLOT2 SLOT3 SLOT4 SLOT5 SLOT6 SLOT7 SLOT8 SLOT9 SCP MCP LCP PSU B PSU60 PS...

Page 60: ...erv INSTALLATION TECHNICAL MANUAL PART 3 MARCH 2004 X X X X X X xxxxxxxxx TRUNK B CARD TRUNK B1 CARD TRUNK C1 CARD GTRK CARD DID CARD E M CARD DLI CARD 16DLI CARD SLI CARD 8SLI CARD 16SLI CARD BRI CAR...

Page 61: ...TEPRI CARD FIGURE 3 18 iDCS 500 Release 2 OfficeServ INSTALLATION TECHNICAL MANUAL PART 3 MARCH 2004 Home Page Table of Contents...

Page 62: ...AAUCD CARD FIGURE 3 19 iDCS 500 Release 2 OfficeServ INSTALLATION TECHNICAL MANUAL PART 3 MARCH 2004 Home Page Table of Contents...

Page 63: ...8WLI FIGURE 3 20 iDCS 500 Release 2 OfficeServ INSTALLATION TECHNICAL MANUAL PART 3 MARCH 2004 NOT AVAILABLEYET Home Page Table of Contents...

Page 64: ...SVMi 8 SVMi 16E FIGURE 3 21 iDCS 500 Release 2 OfficeServ INSTALLATION TECHNICAL MANUAL PART 3 JANUARY 2004 SVMi 8 SVMi 16E Home Page Table of Contents...

Page 65: ...MGI2 CARD FIGURE 3 22 iDCS 500 Release 2 OfficeServ INSTALLATION TECHNICAL MANUAL PART 3 MARCH 2004 Home Page Table of Contents...

Page 66: ...MGI3 CARD FIGURE 3 23 iDCS 500 Release 2 OfficeServ INSTALLATION TECHNICAL MANUAL PART 3 MARCH 2004 Home Page Table of Contents...

Page 67: ...E911 CARD FIGURE 3 24 iDCS 500 Release 2 OfficeServ INSTALLATION TECHNICAL MANUAL PART 3 MARCH 2004 E 9 1 1 ST ALM L1 L2 L3 L4 P1 P2 Home Page Table of Contents...

Page 68: ...4 BRI DIP SWITCH LOCATIONS FIGURE 3 25 iDCS 500 Release 2 OfficeServ INSTALLATION TECHNICAL MANUAL PART 3 MARCH 2004 DIP SWITCH 4 DIP SWITCH 3 DIP SWITCH 2 DIP SWITCH 1 Home Page Table of Contents...

Page 69: ...d The SEPU rating of all cards that consume 48V is shown in the table below Card Type SEPU Rating Notes WLI 32 Each Channel counts as a port 16 DLI 16 8 DLI 16 Each B channel counts as a port 16 SLI 1...

Page 70: ...S SLI NO SVMi 8 SVMi 16E NO 4 BRI NO E M NO DID NO GTRK NO MGI 2 NO WLI NO To determine which PSU is supplying each card or to determine if a card is turned on or off or how many ports are active on a...

Page 71: ...not corrected power down and remove the MCP2 card Check the MCP2 to ensure it is configured correctly Remember the MCP2 MUST have a ESM and IPM installed to operate in a multiple cabinet system and th...

Page 72: ...MCP2 reads each slot for the existence of a card and identifies the type of card It stores this information as the default configuration The trunk card in the lowest slot number is assigned trunk num...

Page 73: ...station or trunk cards come up without directory numbers The above examples describe a system using a three digit numbering scheme If the DIP switches on the MCP2 are changed then the default numbers...

Page 74: ...SETTING VOLTAGE ON PSU 60 FIGURE 4 1 110 VOLTAGE SETTING FUSES iDCS 500 Release 2 OfficeServ INSTALLATION TECHNICAL MANUAL PART 4 MARCH 2004 Home Page Table of Contents...

Page 75: ...ROUND START LINES Using one pair twisted 24 AWG or 26 AWG jumper wire cross connect each ground start C O line to the GTRK port of your choice see Figure 5 3 5 4 DID LINES Using one pair twisted 24 AW...

Page 76: ...rface with a cable supplied by the CSU manufacturer If this is not possible or practical a custom cable has to be made up This cable should be made from 22 gauge two pair cable with each pair individu...

Page 77: ...O TIP C O RING C O TIP C O RING C O TIP C O RING TELCO PROVIDED NETWORK ACCESS JACK RJ 11C RJ 14C RJ 21X MDF CONNECTIONS LOOP START LINE TO TRUNK B OR TRUNK B1 CARD 4 NO OTHER CONNECTIONS FIGURE 5 1 i...

Page 78: ...CIRCUIT FUNCTION 26 1 27 2 W BL BL W W O O W 1 2 3 4 1 5 28 3 29 4 W GN GN W W BR BR W 5 6 7 8 30 5 31 6 W S S W R BL BL R 9 10 11 12 2 6 3 7 C O TIP C O RING C O TIP C O RING C O TIP C O RING C O TIP...

Page 79: ...W W O O W 1 2 3 4 1 28 3 29 4 W GN GN W W BR BR W 5 6 7 8 30 5 W S S W 9 10 2 3 25 PAIR CABLE WITH FEMALE CONNECTOR TO ANY GTRK CARD C O TIP C O RING C O TIP C O RING C O TIP C O RING C O TIP C O RIN...

Page 80: ...RING DID TIP DID RING DID TIP DID RING DID TIP DID RING DID TIP CONNECT TO ANY CIRCUIT ON ANY DID CARD NOTE ONLY DID LINES CAN BE CONNECTED TO A DID CARD TELCO PROVIDED NETWORK ACCESS JACK RJ 11C RJ 1...

Page 81: ...COLOR TERM CIRCUIT FUNCTION 26 1 27 2 W BL BL W W O O W 1 2 3 4 1 5 6 28 3 29 4 W GN GN W W BR BR W 5 6 7 8 30 5 31 6 W S S W R BL BL R 9 10 11 12 2 3 4 7 8 C O TIP C O RING E1 M1 E2 M2 E3 M3 E4 M4 C...

Page 82: ...J 11C RJ 14C RJ 21X PIN COLOR TERM CIRCUIT FUNCTION 26 1 27 2 W BL BL W W O O W 1 2 3 4 1 28 3 29 4 W GN GN W W BR BR W 5 6 7 8 30 5 31 6 W S S W R BL BL R 9 10 11 12 2 3 SLT TIP SLT RING SLT TIP SLT...

Page 83: ...CE UNIT TELCO T1 SPAN FIGURE 5 7 iDCS 500 Release 2 OfficeServ INSTALLATION TECHNICAL MANUAL PART 5 MARCH 2004 8 7 6 5 4 3 2 1 RECEIVE PAIR TRANSMIT PAIR CUSTOMER PROVIDED MALE RJ 45 ENDED CABLE LOS L...

Page 84: ...ON CIRCUIT TERM COLOR PIN 5 6 28 3 TX TIP TX RING 2 7 8 W BR BR W 29 4 RCV TIP RCV RING 2 9 10 W SL SL W 30 5 11 12 31 6 TX TIP TX RING 3 13 14 R O O R 32 7 RCV TIP RCV RING 3 15 16 R GN GN R 33 8 17...

Page 85: ...f fire use only No 26 AWG or larger telecommu nication line cord NOTE Because the iDCS 500 is a self configuring system if you connect a 12 button keyset to a DLI port that previously had a 24 button...

Page 86: ...fire use only No 26 AWG or larger telecommu nication line cord When a customer provided electric door release is installed cross connect the corresponding door release contacts on the DPIM to the doo...

Page 87: ...om the keyset and mount the wedge to the wall using one of the methods below see Figure 6 6a Use screw holes 1 and 2 to attach the base wedge to a standard electrical outlet box OR Use screw holes 1 a...

Page 88: ...the keyset and place it to the right of the 64 Button Module and attach the bracket 64 BM to the keyset with the remaining two screws The base wedge can now be replaced NOTE If you wish to attach two...

Page 89: ...erface required by the station equipment In this case the maximum distance of the BRI station equipment from the iDCS 500 is determined by the specifications of the NT1 Using two pair twisted 24 AWG o...

Page 90: ...W R BL BL R 9 10 11 12 32 7 33 8 R O O R R GR GR R 13 14 15 16 34 9 35 10 R BR BR R R S S R 17 18 19 20 36 11 BK BL BL BK 21 22 2 3 4 5 6 7 8 25 PAIR CABLE WITH FEMALE CONNECTOR TO ANY DLI CARD ONE P...

Page 91: ...5 6 29 4 W BR BR W 7 8 3 DLI TIP DLI RING 30 5 W SL SL W 9 10 4 DLI TIP DLI RING 31 6 R BL BL R 11 12 32 7 R O O R 13 14 5 DLI TIP DLI RING 33 8 R GN GN R 15 16 6 DLI TIP DLI RING 34 9 R BR BR R 17 18...

Page 92: ...BL BL R 9 10 11 12 32 7 33 8 R O O R R GR GR R 13 14 15 16 34 9 35 10 R BR BR R R S S R 17 18 19 20 36 11 BK BL BL BK 21 22 2 3 4 5 6 7 8 25 PAIR CABLE WITH FEMALE CONNECTOR TO ANY DLI CARD ONE PAIR T...

Page 93: ...DLI TIP DLI RING 31 6 R BL BL R 11 12 32 7 R O O R 13 14 5 DLI TIP DLI RING 33 8 R GN GN R 15 16 6 DLI TIP DLI RING 34 9 R BR BR R 17 18 35 10 R SL SL R 19 20 7 DLI TIP DLI RING 36 11 BK BL BL BK 21...

Page 94: ...2 28 3 29 4 30 5 31 6 COLOR W BL BL W W O O W W GN GN W W BR BR W W S S W R BL BL R TERM 1 2 3 4 5 6 7 8 9 10 11 12 CIRCUIT 1 2 3 4 1 3 5 2 4 6 R G BK Y W BL ONE PAIR TWISTED SHEATHED STATION CABLE 24...

Page 95: ...W GN GN W W BR BR W 5 6 7 8 30 5 31 6 W S S W R BL BL R 9 10 11 12 32 7 33 8 R O O R R GR GR R 13 14 15 16 34 9 35 10 R BR BR R R S S R 17 18 19 20 36 11 BK BL BL BK 21 22 2 3 4 5 6 7 8 25 PAIR CABLE...

Page 96: ...8 30 5 31 6 W S S W R BL BL R 9 10 11 12 32 7 33 8 R O O R R GR GR R 13 14 15 16 34 9 35 10 R BR BR R R S S R 17 18 19 20 36 11 BK BL BL BK 21 22 2 3 4 5 6 7 8 25 PAIR CABLE WITH FEMALE CONNECTOR TO...

Page 97: ...BL R 11 12 32 7 R O O R 13 14 5 SLT TIP SLT RING 33 8 R GN GN R 15 16 6 SLT TIP SLT RING 34 9 R BR BR R 17 18 35 10 R SL SL R 19 20 7 SLT TIP SLT RING 36 11 BK BL BL BK 21 22 8 SLT TIP SLT RING 37 12...

Page 98: ...SLT TIP SLT RING 31 6 R BL BL R 11 12 32 7 R O O R 13 14 5 SLT TIP SLT RING 33 8 R GN GN R 15 16 6 SLT TIP SLT RING 34 9 R BR BR R 17 18 35 10 R SL SL R 19 20 7 SLT TIP SLT RING 36 11 BK BL BL BK 21 2...

Page 99: ...18 19 20 36 11 BK BL BL BK 21 22 2 3 4 5 6 7 8 25 PAIR CABLE WITH FEMALE CONNECTOR TO ANY DLI CARD ONE PAIR TWISTED SHEATHED STATION CABLE 24 OR 26 AWG CONNECT TO ANY CIRCUIT ON ANY DLI CARD NO OTHER...

Page 100: ...W 3 4 2 SLT TIP SLT RING 28 3 W GN GN W 5 6 29 4 W BR BR W 7 8 3 SLT TIP SLT RING 30 5 W SL SL W 9 10 4 SLT TIP SLT RING 31 6 R BL BL R 11 12 32 7 R O O R 13 14 5 SLT TIP SLT RING 33 8 R GN GN R 15 1...

Page 101: ...FIGURE 6 5 HOLES FOR MOUNTING SCREWS 2 3 5 4 1 NOTE THE DIRECTORY CARD SLIDE TRAY IS NOT USED WHEN THE KEYSET IS WALL MOUNTED iDCS 500 Release 2 OfficeServ INSTALLATION TECHNICAL MANUAL PART 6 MARCH...

Page 102: ...2 OfficeServ INSTALLATION TECHNICAL MANUAL PART 6 MARCH 2004 HOLES FOR MOUNTING SCREWS NOTE THE DIRECTORY CARD SLIDE TRAY IS NOT USED WHEN THE KEYSET IS WALL MOUNTED 1 2 3 USED FOR ATTACHING AOM OR 64...

Page 103: ...FIGURE 6 7 WALL MOUNTING AN iDCS KEYSET FIGURE 6 6a iDCS 500 Release 2 OfficeServ INSTALLATION TECHNICAL MANUAL PART 6 MARCH 2004 1 2 3 Home Page Table of Contents...

Page 104: ...TO 64BM FIGURE 6 7 iDCS 500 Release 2 OfficeServ INSTALLATION TECHNICAL MANUAL PART 6 MARCH 2004 METAL CONNECTOR CLIP 24B 12B ULTRA BASE WEDGE 64BM ULTRA BASE WEDGE GROOVE FOR ADDITIONAL CONNECTOR CLI...

Page 105: ...TO AOM FIGURE 6 8 iDCS 500 Release 2 OfficeServ INSTALLATION TECHNICAL MANUAL PART 6 MARCH 2004 METAL CONNECTOR CLIP 24B 12B ULTRA BASE WEDGE AOM ULTRA BASE WEDGE GROOVE FOR ADDITIONAL CONNECTOR CLIP...

Page 106: ...M FIGURE 6 9 iDCS 500 Release 2 OfficeServ INSTALLATION TECHNICAL MANUAL PART 6 MARCH 2004 METAL CONNECTOR CLIP 7B SINGLE LINE ULTRA BASE WEDGE AOM ULTRA BASE WEDGE 7B SINGLE LINE ULTRA BASE WEDGE 64B...

Page 107: ...FIGURE 6 7 ATTACHING iDCS 64 BUTTON MODULE TO AN iDCS KEYSET FIGURE 6 10 iDCS 500 Release 2 OfficeServ INSTALLATION TECHNICAL MANUAL PART 6 MARCH 2004 Home Page Table of Contents...

Page 108: ...7 ATTACHING iDCS 14 BUTTON MODULES TO AN iDCS KEYSET FIGURE 6 11 iDCS 500 Release 2 OfficeServ INSTALLATION TECHNICAL MANUAL PART 6 MARCH 2004 REMOVE KNOCKOUTS CONNECT RIBBON CABLE Home Page Table of...

Page 109: ...VOLTS PAIR OPTIONAL See Note Note Provide only if BRI Station Equipment requires power from the DCS 500si System PAIR FUNCTION CIRCUIT TERM COLOR PIN 5 6 28 3 TX TIP TX RING 2 7 8 W BR BR W 29 4 RCV...

Page 110: ...SIC for background music See the Programming Section for instructions MMC 308 7 2 EXTERNAL PAGING Each MISC daughter board provides a voice pair and a two dry contact pairs to be used with customer pr...

Page 111: ...for common bell operation are the following a Wire the loud ringing device to the common bell control contact pair b Set contacts for continuous or steady operation c Program the hunt group to include...

Page 112: ...Attach a male DB9 connector to the SIO end and one that meets the requirements of the PC to the other end This cable must not exceed 300 feet Use MMC 804 to set the transmission parameters for the ser...

Page 113: ...batteries directly on a concrete floor This causes them to discharge very quickly c Follow the battery manufacturer s recommended installation and maintenance procedures 7 9 LOUD BELL INTERFACE When a...

Page 114: ...E 7 1 iDCS 500 Release 2 OfficeServ INSTALLATION TECHNICAL MANUAL PART 7 MARCH 2004 CUSTOMER PROVIDED MUSIC SOURCE 1 CUSTOMER PROVIDED MUSIC SOURCE 2 1 2 3 4 5 6 7 8 8 CONDUCTOR PLUG MISC 1 MISC 2 PIN...

Page 115: ...ase 2 OfficeServ INSTALLATION TECHNICAL MANUAL PART 7 MARCH 2004 CUSTOMER PROVIDED AMPLIFIER FOR PAGING CUSTOMER PROVIDED AMPLIFIER FOR LOUD BELL OUTPUT 8 CONDUCTOR PLUG 6 CONDUCTOR PLUG PINS 1 8 TONE...

Page 116: ...CAL MANUAL PART 7 MARCH 2004 MISC 1 MISC 2 1 2 3 4 5 6 7 8 8 CONDUCTOR PLUG 6 CONDUCTOR PLUG PAGE RELAY CONTACT 2 2 7 PAGE RELAY CONTACT 1 3 6 COMMON BELL RELAY CONTACT 4 5 PINS 2 7 PINS 3 6 PINS 4 5...

Page 117: ...T T SIO1 SIO2 SIO3 SIO4 LAN PSU B SLOT1 SLOT2 SLOT3 SLOT4 SLOT5 SLOT6 SLOT7 SLOT8 SLOT9 SCP MCP LCP PSU B PSU60 PSU B SLOT1 SLOT2 SLOT3 SLOT4 SLOT5 SLOT6 SLOT7 SLOT8 SLOT9 SCP MCP LCP PSU B PSU60 PSU...

Page 118: ...GND 5 DTR 4 2 3 5 4 3 2 7 20 OR 9 PIN COM 1 25 PIN COM 2 FIGURE 7 6 PIN CONNECTIONS FOR IOM BOARD TO PRINTER IOM BOARD PRINTER RXD 2 TXD 3 GND 5 DTR 4 2 3 7 20 FIGURE 7 5 iDCS 500 Release 2 OfficeServ...

Page 119: ...L W W O O W 1 2 3 4 1 SLT TIP SLT RING SLT TIP SLT RING SLT TIP SLT RING SLT TIP SLT RING SLT TIP SLT RING SLT TIP SLT RING SLT TIP SLT RING SLT TIP SLT RING 28 3 29 4 W GN GN W W BR BR W 5 6 7 8 30 5...

Page 120: ...TION TECHNICAL MANUAL PART 7 MARCH 2004 12V 12V 12V 12V 6V 6V 6V 6V 6V 6V 6V 6V OPTION A OPTION B BATTERIES SHOULD BE PLACED WITHIN THREE FEET OF KSU CONNECT TO EITHER A OR B WHITE BLACK RESERVE POWER...

Page 121: ...ard See Figure 8 1 NOTE The circuitry on a FKDBS does not provide a loop open disconnect signal or have the over voltage protection necessary for OPX operation 8 3 iDCS KDB FULL DUPLEX FKDBF The stand...

Page 122: ...e that the modular socket shows through the access hole in the base see Figure 8 4 Invert the base assembly over the keyset and plug the ribbon cable into the socket on the keyset PCB see Figure 8 5 w...

Page 123: ...Place the keyset face down on a flat surface Remove the base pedestal by placing your thumbs over the attachment clips and press outward while simultaneously pressing down on the keyset body with you...

Page 124: ...TEL HANDSET RETAINING SCREWS RETAINING SCREWS KEYSET BASE FIGURE 8 2 iDCS 500 Release 2 OfficeServ INSTALLATION TECHNICAL MANUAL PART 8 MARCH 2004 Home Page Table of Contents...

Page 125: ...MOUNTING SCREWS RIBBON CABLE CONNECTOR INSTALLING KBD DLI DAUGHTERBOARD FIGURE 8 3 iDCS 500 Release 2 OfficeServ INSTALLATION TECHNICAL MANUAL PART 8 MARCH 2004 Home Page Table of Contents...

Page 126: ...TEL HANDSET OUTPUT JACK KEYSET DAUGHTERBOARD OUTPUT JACK FIGURE 8 4 iDCS 500 Release 2 OfficeServ INSTALLATION TECHNICAL MANUAL PART 8 MARCH 2004 Home Page Table of Contents...

Page 127: ...GHTERBOARD INTO RIBBON CABLE CONNECTOR P7 HOOK P1 P7 P2 SP MIC CONNECTING KEYSET DAUGHTERBOARD TO KEYSET PCB FIGURE 8 5 iDCS 500 Release 2 OfficeServ INSTALLATION TECHNICAL MANUAL PART 8 MARCH 2004 Ho...

Page 128: ...MOUNTING SCREWS RIBBON CABLE CONNECTOR INSTALLING KDB SLI DAUGHTERBOARD FIGURE 8 6 iDCS 500 Release 2 OfficeServ INSTALLATION TECHNICAL MANUAL PART 8 MARCH 2004 Home Page Table of Contents...

Page 129: ...T OUTPUT JACK OUTPUT JACK FIRST KEYSET SECOND KEYSET LINE CORD TEL HANDSET FIRST KEYSET SINGLE LINE TELEPHONE LINE CORD VOL SPK HOLD TRSF ANS 1 2ABC 3 DEF 4 GHI 5 JKL 6 MNO 7 PRS 8TUV 9 WXY 0OPER RLS...

Page 130: ...ATION CABLE MULTI PAIR STATION CABLE CONNECT TO KEYSET OR SLT DEPENDING ON KDB TYPE VOL SPK HOLD TRSF ANS 1 2 ABC 3 DEF 4 GHI 5 JKL 6 MNO 7 PRS 8 TUV 9 WXY 0 OPER RLS SCROLL CONNECTING A STATION DEVIC...

Page 131: ...8 and will be stored in those cards on board flash memory The cards will automatically reboot load and run the new software when the download process is complete Using PCMMC over a LAN connection to t...

Page 132: ...ailed in Figure 10 1 10 2 GRADING THE iDCS 500 FOR DTMF RECEIVERS DSP s Digital Signal Processors are used in the iDCS 500 system as DTMF receivers Considerations must be made when using features of t...

Page 133: ...as four dedicated analog DTMF receivers One receiver is dedicated to each port on this card and only this card These analog receivers cannot be used by any other system device They are NOT a common re...

Page 134: ...3 SLOT4 SLOT5 SLOT6 SLOT7 SLOT8 SLOT9 SCP MCP LCP PSU B PSU60 C3 S1 LCP P W R B A T T PSU B SLOT1 SLOT2 SLOT3 SLOT4 SLOT5 SLOT6 SLOT7 SLOT8 SLOT9 SCP MCP LCP PSU B PSU60 PSU B SLOT1 SLOT2 SLOT3 SLOT4...

Page 135: ...progress ACT LED FLASHING GREEN AP D SD Green HD Flashing PGD Red SVMi 8 software is initializing SVMi 8 is not ready to process calls RESET BUTTON The red button marked RST is the reset button Pressi...

Page 136: ...N steady green Either of these conditions indicates normal operation as defined in the table above On the SVMi 16E the PGD must be red and the AP D and SD LEDS must be red as well 5 iDCS PROGRAMMING P...

Page 137: ...Mi 16E answers 2 Call group 529 549 and confirm that SVMi 8 SVMi 16E answers If steps 1 and 2 above proved to be successful you have completed the installation and setup of the SVMi 8 SVMi 16E hardwar...

Reviews: