iDCS 500
PROGRAMMING
TECHNICAL MANUAL
PART 2 SEPTEMBER 2003
MMC: 501
SYSTEM
TIMERS
DESCRIPTION:
Allows the technician to adjust individual timers as necessary.
NOTE: Certain timers are disabled when the value is “000”.
PROGRAM KEYS
UP & DOWN
Used to scroll through options
KEYPAD
Used to enter selections
SOFT KEYS
Move cursor left and right
SPK
Used to store data and advance to next MMC
ACTION
DISPLAY
1. Press TRSF 501
Display shows first timer value
AA INT DGT TIME
05 SEC
2. Press UP or DOWN key to select timer and
press RIGHT soft key to move cursor
KMMC LOCK OUT TM
30 SEC _
3. Enter new value using keypad; if valid, system
returns to step 2 with new value
KMMC LOCK OUT TM
30 SEC 250
4. Press TRSF to store and exit
OR
Press SPK to store and advance to next MMC
DEFAULT DATA: SEE TABLE OF TIMERS AND VALUES
RELATED ITEMS: NONE
HELP
Table of
Contents
HOME
PAGE