iDCS 100
INSTALLATION
TECHNICAL MANUAL
PART 11 JUNE 2002
11.4
11.9 ADDING AN SPLL DAUGHTER BOARD
1. Check the battery switch on the MEM3 or MEM4 card and make sure it is on.
2. Turn off power to the system and unplug the power cord.
3. Install the SPLL card onto its connectors in the bottom left hand corner of the KSU
motherboard
4. Restore power to the system.
NOTE: The SPLL DAUGHTER BOARD is required in system to support BRI operation.
11.10 ADDING A MODEM CARD
1. Check the battery switch on the MEM3 or MEM4 card and make sure it is on.
2. Turn off the power to the system and unplug the power cord.
3. Remove the SMISC card from its slot, and lay card on a soft surface, component
side up.
4. Install the MODEM card onto its connectors on the SMISC card
NOTE: The white arrow on the MODEM card should point away from the KSU
Motherboard when SMISC card is re-inserted.
5. Re-insert SMISC card into the appropriate slot.
6. Restore power to the system.
7. Open system programming and use
to assign a directory number to the card, the default extension
number is 359.