3. Disassembly and Reassembly
3-1 Removing Cover-Back Main Wire, Cover-Back Guard Wire and PCB-
Main
WARNING
ELECTRICAL SHOCK HAZARD
Disconnect power before servicing the range . Replace all panels before operating range . Failure to do so
can result in death or electrical shock .
PRECAUTION
When you work on the electric range, be careful when handling the sheet metal parts . Sharp
edges may be present, and you can cut yourself if you are not careful .
Parts
Explaination Photo
Explaination
Cover-Back Main
Wire, Cover-
Back Guard Wire
and PCB-Main
1.
Turn off the electrical supply
going to the range .
2.
Pull the range away from the
wall so that you can access the
rear panel .
3.
Remove the 8 screws from the
Cover-Back Main Wire and
remove the panel .
4.
Remove 3 screws from the
Cover-Back Guard Wire and
remove the cover .
5.
Remove 2 screws of PCB Main
and separate PCB Main .
Cover-Back
Guard Wire
Cover-Back
Main Wire
PCB Main