7. Electrical installation
Installer reference guide / Mono tank integrated type
119
To connect smart grid
• To control the ClimateHub via external smart grid (SG) input signals (potential free, dry contact), please connect to the
correct terminals (Signal1 (1/2), Signal2 (3/4)).
If needed use relays, not supplied with the product.
1
3
2
4
6
5
7
9
8
10
12
11
13
15
14
16
18
17
20
19
1
3
5
7
9
15
11
17
2
4
6
8
14
10
16
12
18
13
19
20
SG READY Signal 1
SG READY Signal 2
SG READY Signal 1
SG READY Signal 2
Description
Short
Open
Forced thermo off operation
Open
Open
Normal operation
Open
Short
Heating / DHW setting temperature 1step-up operation
Short
Short
Heating / DHW setting temperature 2step-up operation
CAUTION