Page 1: ...SAMSUNG DVM Pro 2008 User Guide 1 SAMSUNG DVM Pro 2008 User s Manual Sales mode English Version 2008 02 28 ...

Page 2: ... name 3 1 2 Country 3 1 3 Customer Information 3 1 4 Designer Information 3 2 Setup Space 3 3 Workspace management 4 Indoor unit 4 1 Workspace 4 2 Add Indoor 4 3 Edit Indoor 4 4 Delete Indoor 4 5 View Indoor 4 6 Setup options 5 Outdoor unit 5 1 Workspace 5 2 Add Outdoor 5 3 Edit Outdoor 5 4 Delete Outdoor 5 5 Copy Outdoor 5 6 Compensate Outdoor 5 7 Window for Outdoor Information 5 8 Indoor which n...

Page 3: ... Select Piping connection tools 6 2 3 Basic Pipe Standard Pipe Manual Pipe 6 2 4 Draw Piping manually 6 2 5 View Diagram 6 2 6 Check System 7 Wiring 8 Control System 9 Report 9 1 Insert Logo 9 2 Reporting Information 9 3 Workspace to include in Report 9 4 Currency 9 4 Takes Report off ...

Page 4: ...e to next step if no completion of current step because these works would be executed step by step 2 Top Down menu This menus are shown on upper end the screen and configured with File View Setup and Help If select each menu it shows the related commands 2 1 File Configured wiith NEW Open Close Save Save As and View Recent files 2 2 View Manage the status bar line showing at lower end of program I...

Page 5: ...SAMSUNG DVM Pro 2008 User Guide 5 Conversion ...

Page 6: ...SAMSUNG DVM Pro 2008 User Guide 6 Languages 2 4 Help Show the version information of DVM program and user can move to the related web page directly ...

Page 7: ...f project registration fields if new project Show the related information if it s current project 3 1 1 Project name Enter project name to be registered 3 1 2 Country Select country 3 1 3 Customer information Enter customer information 3 1 4 Designer information Enter designer name 3 2 Setup space Show and edit the building floor name status of connected drawing of Project Press Setup space ...

Page 8: ... Can t duplicate the code name and the code are configured with alphabet and Arabic b Make Floor Form the floor per each building Select the building to make floor Enter the number of floor for Basement and Ground Select Yes if it shows a message that Are you going to make Floor again after delete all floor information if press Make Floor Floor Area Bldg Area ...

Page 9: ...itecture basis drawing of all floors in a file Drawing connection does not mean to connect the each file Select any space under title that is a file in floor area Select drawing to connect after press link file and presses confirmation 3 3 Setup Workspace User can define the same refrigerant product series and A C type to one standard unit All works is done by workspace base If chooses indoor unit...

Page 10: ...ar Model Name part In case of choose Indoor unit on design condition it s displayed the yellow mark in query of Indoor unit c If Indoor unit selection is ended it s added by add button The added Indoor unit appears on Indoor unit query window in right side 4 3 Edit Indoor unit Select and edit the Indoor unit that wish to be edited Select Indoor unit that wish to be edited in Indoor unit query wind...

Page 11: ...ontrol in case of being checked to item connected with control and is controlled individually In case of there is fluorescent light shape in front of Indoor unit name it means the Indoor unit is already connected with that Outdoor unit 4 6 Setup option Can establish option by singleness or multiplex to Indoor unit Press mouse of right button after selects Indoor unit to select option by one or mul...

Page 12: ...d can change and using workspace that is using present in workspace selection window Choose workspace that wish to work 5 2 Add Outdoor Add Outdoor unit to connect the unconnected Indoor unit with Outdoor unit Press confirmation after input the name combination rate floor cooling temperature and heating temperature after press add ...

Page 13: ... to modification of the connected Indoor unit Connect Indoor unit that adds to Outdoor unit in existing or unconnects after add Outdoor unit pressing add button in case of there is the unconnected Outdoor unit Method that connect Indoor unit to addon one or member with name of Outdoor unit to connect tut that press right button after selection by multiplex Gajyeobe ...

Page 14: ...ion rate How to do if ondoor unit were connected with more Indoors than the combination rate Add Outdoor unit Move Indoor unit toward Outdoor which was added User must adjust the combination rate 5 3 Edit Outdoor Edit outdoor after press Edit button after select Outdoor unit to be edited if need to edit Outdoor unit ...

Page 15: ...Outdoor unit to delete It would be deleted if presses yes Now Indoor units had connected with the deleted Outdoor unit would be moved to unconnected Indoor unit window on right side lower column 5 5 Copy Indoor Selects Outdoor unit that wish to copy Presses copy button It shows a message whether user will copy the selected Outdoor unit and the related Indoor unit It s done if presses yes ...

Page 16: ...d compensation option among compensation and heating compensation selects necessary segment Choose installation position of Indoor unit and Outdoor unit Press Simulation after input design condition of Indoor unit design condition of Outdoor unit alike Piping Length The Piping Height if it s any issue to performance compensation it happened an error message if it s no issue to performance compensa...

Page 17: ...M Pro 2008 User Guide 17 5 7 Window of Outdoor Information The detailed information regarding Outdoor unit and Indoor unit on the right end screen is seen automatically Impossible to edit the detailed information ...

Page 18: ... wish to work 6 2 Piping 6 2 1 Select Outdoor Can select ONLY piping system diagram of Outdoor unit wanting in the same workspace 6 2 2 Select Piping connection tool If User starts to draw Piping diagram after translate to manual Pipe it will be activated It s ok if drag and drop the connection tool to need when design by manual Pipe 6 2 3 basic pipe standard Pipe and manual Pipe User can apply an...

Page 19: ...n tool is activated Remove Net It shows Remove Net if press a right mouse on the Ref Joint that is blue triangle part of piping system diagram or on the Indoor unit If select Remove Net the pipe at lower of the selected Ref Joint will be disappeared and next Indoor of Ref Joint will be moved to No linked Indoor Before Remove Net ...

Page 20: ...pty box appears and inserts the connection tool in the box and can connect user free piping After insert piping connection tool It s inserted if put in empty quadrilateral attracting Indoor unit that unconnect after link the connection tool Image that Indoor units are inserted ...

Page 21: ...h Input Pipe length shows if presses a right mouse on Ref Joint that is blue triangle part of piping system diagram or Indoor unit can input length of each piping and give an effect to check system if the length is inputted 6 2 7 Check System Examine piping connection state Pipe length the difference between floors and etc If press Check system it s opened window of Check system ...

Page 22: ... length Do you apply the piping length of all visible units If window that will apply together comes out press yes Press Yes after enter piping length to apply Press beginning button In case of there is no issue it shows Check system completion message and an addition refrigerant quantity appears in window of Check system ...

Page 23: ...spections are expressed blue to piping system diagram and it means that it s no issue to show blue color If there is any issue while checking the system it shows error message if confirm the system piping diagram pipe that problem happens was expressed in red color ...

Page 24: ...ow electricity wiring state of indoor outdoor units 7 1 Workspace It shows details information about workspace that displays and can change and uses workspace that is using present in window of workspace selection Choose workspace that wish to work ...

Page 25: ...me workspace 8 Control system Form control system Press addition button and input a name Include Outdoor units to add in control using middle transfer button It s excepted in control if it s checked in K2 options among Indoor unit Press Setup system Continue the decided steps after selects control system and presses confirmation ...

Page 26: ...SAMSUNG DVM Pro 2008 User Guide 26 If is ended control diagram appears on screen 9 Report ...

Page 27: ...ng diagram and estimates and displays or prints ONLY the checked report 9 3 Workspace to include to report when print out report can choose workspace Outdoor unit etc that wish to display to user at free 9 4 Currency Can choose currency 9 5 If user free selection ends print the report with makes report button If check open by word processor the edit window is activated as soon as do make report ...