English
17
Installation requirements
Gas requirements
WARNING
• Use only natural or LP (liquid propane) gases.
• The installation must be conformed with local codes, or in the absence of local codes,
with the national fuel gas code, ANSI Z223.1/NFPA 54, latest revision(for the UNITED
STATES), or with the natural gas and propane installation code, CSA B149.1(for Canada).
• Gas dryers are equipped with a burner vent for use with natural gas. If you plan to
use your dryer with LP (liquid propane) gas, it must be converted for safe and proper
performance by a qualified service technician.
(LNG models only)
You must check the burner of your model and use the proper LP Kit accordingly. To
check the detail information of the burner, open the door and check the rating label
location on the door frame.
- 20,000 BTU: LPKIT-4/XAA (DC98-04114A)
- 22,000 BTU: LPKIT-3/XAA (DC99-00792A)
• A 1/2” (1.27 cm) gas supply line is recommended and must be reduced to connect to
the 3/8” (1 cm) gas line on your dryer. The National Fuel Gas Code requires that an
accessible, approved manual gas shut-off valve be installed within 6” of your dryer.
• Gas dryers installed in residential garages must be raised 18 inches (46 cm) above the
floor.
• Additionally, a 1/8” (0.3 cm) N.P.T. (National Pipe Thread) plugged tapping, accessible
for test gauge connection, must be installed immediately upstream of your dryer’s gas
supply connection.
• Your dryer must be disconnected from the gas supply pipe system during any pressure
testing of the system.
• Do not reuse old flexible metal gas lines. Flexible gas lines must be designed and
certified by the standard for connectors for Gas Appliances, ANSI Z21.24 • CSA 6.10.
NOTE
• Your dryer uses an automatic ignition system to ignite the burner. There is no constant
burning pilot.
• Any pipe joint compound used must be resistant to the action of any liquefied
petroleum gas.
• As a courtesy, most local gas utilities will inspect a gas appliance installation.
Untitled-10 17
2020-07-14 3:22:13
Summary of Contents for DVG45T6005 Series
Page 1: ...Dryer User manual DVE G 45T6005 DVE G 45T6000 Untitled 10 1 2020 07 14 3 22 11 ...
Page 61: ...Memo Untitled 10 61 2020 07 14 3 22 24 ...
Page 62: ...Memo Untitled 10 62 2020 07 14 3 22 24 ...
Page 63: ...Memo Untitled 10 63 2020 07 14 3 22 24 ...
Page 65: ...Sèche linge Manuel d utilisation DVE G 45T6005 DVE G 45T6000 Untitled 12 1 2020 07 14 3 27 39 ...
Page 125: ...Mémo Untitled 12 61 2020 07 14 3 27 51 ...
Page 126: ...Mémo Untitled 12 62 2020 07 14 3 27 51 ...
Page 127: ...Mémo Untitled 12 63 2020 07 14 3 27 51 ...
Page 129: ...Secadora Manual del usuario DVE G 45T6005 DVE G 45T6000 Untitled 11 1 2020 07 14 3 25 02 ...
Page 190: ...Notas Untitled 11 62 2020 07 14 3 25 15 ...