English
15
Installation requirements
Ducting requirements
Weather hood type
Recommended
Use only for short-run
installation
4” (10.2 cm)
2.5” (6.4 cm)
No. of 90° elbows
Rigid
Rigid
0
80 ft. (24.4 m)
74 ft. (22.6 m)
1
68 ft. (20.7 m)
62 ft. (18.9 m)
2
57 ft. (17.4 m)
51 ft. (15.5 m)
3
47 ft. (14.3 m)
41 ft. (12.5 m)
NOTE
* Use a 4-inch (10.2 cm) diameter rigid aluminum or galvanized steel duct.
If you integrate the dryer’s vent system with an existing exhaust system:
• Make sure the exhaust system meets all applicable local, state, and national regulations.
• Verify you are not using flexible plastic duct.
• Make sure to check for and remove all lint buildup from inside the existing ducts.
• Confirm the duct is not kinked or crushed.
• Make sure the exhaust hood damper opens and closes freely.
Manometer measurements
The static pressure in any exhaust system must not exceed 0.83 inches of water column
or be less than 0. Note that these values are measured with the dryer running with a
manometer presented to the exhaust duct that connects to the dryer. The dryer tumbler
must be empty and lint filter clean.
Untitled-10 15
2020-07-14 3:22:13
Summary of Contents for DVG45T6005 Series
Page 1: ...Dryer User manual DVE G 45T6005 DVE G 45T6000 Untitled 10 1 2020 07 14 3 22 11 ...
Page 61: ...Memo Untitled 10 61 2020 07 14 3 22 24 ...
Page 62: ...Memo Untitled 10 62 2020 07 14 3 22 24 ...
Page 63: ...Memo Untitled 10 63 2020 07 14 3 22 24 ...
Page 65: ...Sèche linge Manuel d utilisation DVE G 45T6005 DVE G 45T6000 Untitled 12 1 2020 07 14 3 27 39 ...
Page 125: ...Mémo Untitled 12 61 2020 07 14 3 27 51 ...
Page 126: ...Mémo Untitled 12 62 2020 07 14 3 27 51 ...
Page 127: ...Mémo Untitled 12 63 2020 07 14 3 27 51 ...
Page 129: ...Secadora Manual del usuario DVE G 45T6005 DVE G 45T6000 Untitled 11 1 2020 07 14 3 25 02 ...
Page 190: ...Notas Untitled 11 62 2020 07 14 3 25 15 ...