Installation requirements
English
15
Ducting requirements
Recommended
Use only for short-run installation
Weather hood
type
4” (10.2 cm)
2.5” (6.4 cm)
No. of 90°
elbows
Rigid
Rigid
0
80 ft. (24.4 m)
74 ft. (22.6 m)
1
68 ft. (20.7 m)
62 ft. (18.9 m)
2
57 ft. (17.4 m)
51 ft. (15.5 m)
3
47 ft. (14.3 m)
41 ft. (12.5 m)
NOTE
* Use a 4-inch (10.2 cm) diameter rigid aluminum or galvanized steel duct.
If you integrate the dryer’s vent system with an existing exhaust system, make
sure:
• The exhaust system meets all applicable local, state, and national regulations.
• Not to use a flexible plastic duct.
• To regularly check and clean all lint buildup from inside the existing ducts.
• The duct is not kinked or crushed.
• The exhaust hood damper opens and closes freely.
Manometer measurements
The static pressure in any exhaust system must not exceed 0.83 inches of water column
or be less than 0. Note that these values are measured with the dryer running with a
manometer presented to the exhaust duct that connects to the dryer. The dryer drum
must be empty and the lint filter clean.
DV3000A(SEM)_DC68-03784P-00_EN.indd 15
2020-12-07 4:50:50
Summary of Contents for DVE41A3000 Series
Page 1: ...Dryer User manual DVE G 41A3000 DV3000A SEM _DC68 03784P 00_EN indd 1 2020 12 07 4 50 47 ...
Page 58: ...Memo DV3000A SEM _DC68 03784P 00_EN indd 58 2020 12 07 4 51 11 ...
Page 59: ...DV3000A SEM _DC68 03784P 00_EN indd 59 2020 12 07 4 51 11 ...
Page 118: ...Mémo DV3000A SEM _DC68 03784P 00_CFR indd 58 2020 12 07 4 52 41 ...
Page 119: ...DV3000A SEM _DC68 03784P 00_CFR indd 59 2020 12 07 4 52 41 ...
Page 178: ...Notas DV3000A SEM _DC68 03784P 00_MES indd 58 2020 12 07 4 51 55 ...
Page 179: ...DV3000A SEM _DC68 03784P 00_MES indd 59 2020 12 07 4 51 55 ...