Installation requirements
Installation requirements
English
14
Clearance requirement
This clearance requirement is applicable for dryers only.
NOTE
• For the washer’s clearance requirement, see the washer’s user manual.
• If the washer and dryer have different clearance requirements, follow the one with the
larger value.
Alcove or closet installations
WARNING
• The dryer must be exhausted to the outside to reduce the risk of fire when installed in
an alcove or closet.
• No other fuel-burning appliance should be installed in the same closet as the dryer.
• Place the dryer at least 18 in. (460 mm) above the floor for a garage installation.
Minimum clearance for stable operation:
Sides
Top
Rear
Front
1 in. / 25 mm
17 in. / 432 mm
5.9 in. / 150 mm
1 in. / 25 mm
If both the washer and a dryer are installed in the same location, the front of the alcove
or closet must have two unobstructed air openings for a combined minimum total area of
72 in.² (465 cm²).
This clearance requirement is applicable for washer and dryer pair installation.
Side by side installation
A
A
C
D
B
A
1 in. (25 mm)
B
21 in. (533 mm)
C
1 in. (25 mm)
D
5.9 in. (150 mm)
DV3000A(SEM)_DC68-03784P-00_EN.indd 14
2020-12-07 4:50:50
Summary of Contents for DVE41A3000 Series
Page 1: ...Dryer User manual DVE G 41A3000 DV3000A SEM _DC68 03784P 00_EN indd 1 2020 12 07 4 50 47 ...
Page 58: ...Memo DV3000A SEM _DC68 03784P 00_EN indd 58 2020 12 07 4 51 11 ...
Page 59: ...DV3000A SEM _DC68 03784P 00_EN indd 59 2020 12 07 4 51 11 ...
Page 118: ...Mémo DV3000A SEM _DC68 03784P 00_CFR indd 58 2020 12 07 4 52 41 ...
Page 119: ...DV3000A SEM _DC68 03784P 00_CFR indd 59 2020 12 07 4 52 41 ...
Page 178: ...Notas DV3000A SEM _DC68 03784P 00_MES indd 58 2020 12 07 4 51 55 ...
Page 179: ...DV3000A SEM _DC68 03784P 00_MES indd 59 2020 12 07 4 51 55 ...