SAMSUNG
MMC PROGRAMS
COMBINED SYSTEMS PROGRAMMING MANUAL
FEBRUARY 2004
MMC 721 (Page 1 of 1)
MMC: 721
SAVE STATION KEY
PROGRAMMING
FOR:
ALL
SYSTEMS
Purpose:
Prevents the loss of programmable keys on keysets when testing or replace-
ment is required. First the data is saved and then the station can be replaced with an-
other station type or the keys can be reprogrammed to other features. Once testing or
replacement is completed, the data can be restored to the individual station, providing
the same keyset type is used.
Options are SAVE and RESTORE
.
Note: This program is not to be confused with MMC 315 (Set Relocation). MMC 721 is for saving
and restoring the same device type at a port.
ACTION
DISPLAY
1. Open programming and select
721
Display shows
[201] SAVE KEY
RESTORE
2. Enter desired station number (e.g., 205)
OR
Press VOLUME keys to make selection and press
RIGHT soft key
[205] SAVE KEY
RESTORE
3. Press VOLUME keys to select function (e.g.,
SAVE)
[205] SAVE KEY
SAVE
4. Press RIGHT soft key to enter and return to step 2
OR
Press Transfer/TRSF to store and exit
OR
Press SPEAKER to store and advance to next
MMC
Default Data:
RESTORE
Related Items:
MMC 107 Key Extender
MMC 722 Station Key Programming
MMC 723 System Key Programming