Samsung AZ09A1JEA Owner'S Instructions Manual Download Page 1

ENGLISH

ESP

AÑOL

FRANÇAIS

POR

TUGUÊS

IT

ALIANO

OWNER’S INSTRUCTIONS
MANUAL DE INSTRUCCIONES
MANUEL D’UTILISATIO
MANUAL DE INSTRUÇÕES
ISTRUZIONI PER L’USO

AZ09F1SEA
AZ09F1JEA
AZ12F1JEA
AZ18F1MEA
AZ18F1MEB
AZ22F1MEA
AZ22F1MEB
AZ24F1MEA
AZ24F1MEB
AZT18F1MEA
AZT24F1MEA

AZ09A1SEA
AZ09A1JEA
AZ12A1JEA
AZ18A1MEA
AZ18A1MEB
AZ22A1MEA
AZ22A1MEB
AZ24A1MEA
AZ24A1MEB
AZT18A1MEA
AZT24A1MEA

Window-type Room Air Conditioner 

( Cool and Heat )

Acondicionador de aire doméstico sistema de tipo ventana

( Refrigeración y Calefacción )

Climatiseur de type Fenêtre

( Refroidissement et Chauffage )

O ar Condicionado de Window-Type

( Refrigeração e Aquecimento )

Condizionatore d’aria per ambienti da finestra

( Raffreddamento e Riscaldamento )

E S F P I

DB68-01692A(6)

Summary of Contents for AZ09A1JEA

Page 1: ... AZ09A1SEA AZ09A1JEA AZ12A1JEA AZ18A1MEA AZ18A1MEB AZ22A1MEA AZ22A1MEB AZ24A1MEA AZ24A1MEB AZT18A1MEA AZT24A1MEA Window type Room Air Conditioner Cool and Heat Acondicionador de aire doméstico sistema de tipo ventana Refrigeración y Calefacción Climatiseur de type Fenêtre Refroidissement et Chauffage O ar Condicionado de Window Type Refrigeração e Aquecimento Condizionatore d aria per ambienti da ...

Page 2: ...damaged and you may be hurt Keep children away from the unit 5 ALWAYS ensure that the power cable is in good condition Make sure that it is not walked on or damaged by items placed on or against it If the power cord is damaged in any way it must be replaced by an approved power cord available from the manufacturer or its service agent 6 Do NOT attempt to repair the unit yourself If it is damaged i...

Page 3: ...erent symbols PRESS PUSH IMPORTANT NOTE C C C CA A A AU U U UT T T TI I I IO O O ON N N N The maximum permissible system impedance at the power junction box is 0 27 ohms Usually the maximum permissible mains impedance will not be exceeded when the branch to the power outlet is fed from a junction box with a rated current of 32A AZ18 The high inrush current of the starting compressor motor can have...

Page 4: ...lever Power plug The type of power plug may differ depending on the local power supply The power plug may be not supplied depending on the model Air inlet Outside Temperature control dial Operating mode selection dial Air flow blade swing switch Inner air flow blades right left orientation The design and shape are subject to change according to the model E 4 Air outlet ...

Page 5: ...fan speed HI COOL Low fan speed LOW COOL You can change modes at any time 27 C 23 C 29 C 27 C 23 C 18 C Heating Your Room Select the operating mode and fan speed Result The air conditioner starts up in Heat mode The fan starts up at the speed selected To adjust the temperature turn the temperature control dial towards the left and the red position Possible temperatures Between 25 C and 29 C inclus...

Page 6: ...tion Result The air inside the room circulates and stale air is evacuated outside Otherwise push the ventilation lever to the left and the closed position Result The air simply circulates inside the room 2 Set the operating mode selection dial to the FAN position You can switch the air conditioner off whenever you want 1 To switch the unit off simply set the operating mode selection dial to the OF...

Page 7: ...asing the efficiency of the air conditioner 1 Set the air flow blade swing switch to the position Result The inner blades swing automatically left and right 2 To stop the blades moving left and right set the air flow blade swing switch to the position To stop the blades in a specific position and orient the air flow in the corresponding direction simply set the switch to the position when the blad...

Page 8: ...Frost If both the indoor and outdoor temperatures are high and you select the Heat mode the fan and compressor in the unit may stop at times This is normal simply wait until the air conditioner switches on again High indoor and outdoor temperatures If a power failure occurs when the air conditioner is operating the unit is switched off When the power returns the air conditioner starts up again aut...

Page 9: ...l position 4 Wipe the surface of the unit with a neutral detergent and then wipe it again with dry cloth Be sure not to use benzene solvent or other chemical products 5 The removal of the front grille makes it easier to clean the air conditioner Open the grille as much as possible To get the best possible use out of your air conditioner you must clean it regularly by two weeks to remove the dust o...

Page 10: ...dust on the air filter Before cleaning your air conditioner ensure that it is switched off and unplugged from the wall socket Open the front grille by pulling on the tabs of the unit The removal of the front grille makes it easier to clean the air conditioner After opening the front grille lift it up as much as possible then pull down to release it 1 Grasp the handle on the air filter and lift it ...

Page 11: ... fan speed If the air flow is directed downwards direct it upwards When heating the required room temperature is never reached and the air conditioner frequently stops Check that the air conditioner has been switched on if necessary turn the operating mode selection dial refer to page 7 The air flow direction does not change when you set the air flow blade swing switch to the position Air the room...

Page 12: ... conditioner in the north or west side to prevent the effect of direct sunlight When installing it in the south or east side due to unavoidable circumstances it is advisable to install the sunshade to prevent the direct sunlight In this case take care not to cause any hindrance to the flow of outside air 2 When installing the air conditioner be sure to obtain sufficient space on the rear side of t...

Page 13: ...r to page 9 or 10 1 Remove the chassis from the cabinet 5 Remove the rubber cap inserted into the basepan 6 Fix the drain pan as shown in the figure and then connect the drain hose You can use any commercially available drain hose 7 Install the cabinet at the specified area after installing the drain pan and then re assemble it in the original condition 8 Follow steps 6 and 7 only 1 Remove the fro...

Page 14: ...IR CONDITIONER IS MANUFACTURED BY ESTE AIRE ACONDICIONADO HA SIDO FABRICADO POR CE CLIMATISEUR EST FABRIQUE PAR ESTE APARELHO DE AR CONDICIONADO É FABRICADO POR QUESTO CONDIZIONATORE D ARIA È PRODOTTO DA Printed in Korea ...

Reviews: