background image

17

English

Oper

ation F

eatur

es

If you hear a chime sound when you connect the power cord, it means that the power is normally connected.

Turning the power on/off

• 

Press the Power button. The air purifier turns on with a 

notification sound and automatically begins operation.

 

Sensor preparation begins upon startup with a display 

indication  and continues for 12 seconds. The air quality is then 

indicated by color and the concentration level.

 

 Cleanliness color indicator: PM10, PM2.5, PM1.0, GAS

Concentration display: PM10, PM2.5, PM1.0

Sensor loading display

• 

The product operates with the front panel being open about 30 mm. 

 

However, when you turn on the power for only the first time after 

connecting the power cord, the front panel is opened about 40 mm. Then 

the front panel is closed by about 10 mm and the product starts to operate.

• 

When you turn off the power and turn it back on, the product 

operates at the last fan speed you used.

  NOTE

• 

When the air quality level remains the same for a specific period 

of time during operation, All indicators and displays except for 

the cleanliness color indicators turn off and the product enters 

the Energy saving mode. 

 

(This does not apply when using the product in Sleep mode.)

Controlling the fan speed

Use the button to select the intensity of air flow to purify the indoor air.

• 

Press the [ ] button to select the fan speed you want.

 

Each time you press the button, the fan speed changes in the 

order of Low → Medium → High → Auto → Low.

• 

In Auto mode, the fan speed is automatically adjusted to the 

particle and gas pollution levels around it to keep the room clean.

 

When the product operates in the Auto mode for a certain 

period of time and the indoor air becomes clean, the front 

panel comes back into the product’s body and the operation 

mode is switched to the “Auto + Energy saving” mode.

 

The Energy saving mode is automatically released when the indoor air 

becomes bad , or you can cancel it by selecting a fan speed manually.

• 

Fan speed indications

Low

Medium

High

Auto

Operation Features

Operation Features

DB68-08449A-03_IB_ACR AX9500_AA_EN.indd   17

2020-11-27   오후 6:10:13

Summary of Contents for AX300T9080W

Page 1: ...080S AX300T9080W ꞏ ꞏ Thank you for purchasing this Samsung air purifier ꞏ ꞏ Before operating this unit please read this user manual carefully and retain it for future reference DB68 08449A 03_IB_ACR AX9500_AA_EN indd 1 2020 11 27 오후 6 10 10 ...

Page 2: ...an speed 17 Wind Free mode Sleep mode Lock 18 Clearing the filter replacement reminder Turning the Wi Fi feature on off 19 Checking the air quality 20 Using Combined Air Purifiers Combining air purifiers 22 Decombining air purifiers 23 Precautions when using combined air purifiers 24 Cleaning and Maintenance 26 Cleaning the air purifier exterior 26 Cleaning and drying the filters 27 SmartThings ap...

Page 3: ...on with any other antenna or transmitter FCC Radiation Exposure Statement This equipment complies with FCC radiation exposure limits set forth foran uncontrolled environment This equipment should be installed and operated with minimum distance 20cm between the radiator your body IC Radiation Exposure Statement This equipment complies with IC RSS 102 radiation exposure limits set forth for an uncon...

Page 4: ...d current may cause electric shock or fire Do not install the air purifier near a heat source and inflammable objects or in areas that are highly humid or dusty Avoid exposure to oil gas direct sunlight and water Follow instructions to avoid electric shock or fire CAUTION When installing the product make sure that the powerplug can be easilyremovedwhen needed Follow instructions to avoid electric ...

Page 5: ... be replaced by the manufacturer its service agent or similarly qualified persons in orderto avoid a hazard Make sure that the power plug is securely fitted in the socket Do not use it when the plug or cord is damaged Follow instructions to avoid electric shock or fire When you disconnect the power cord pull it by the plug Do not pull the cord itself Follow instructions to avoid electric shock or ...

Page 6: ...th excessive force or pull or press the front panel forcefully Failure to do so may result in fire a product malfunction injury noise or deformation Store the plastic package away from children or discard it according to the law Follow instructions to protect children from a risk of suffocation Do not insert yourfinger or other objects into the air inlet or outlet Take special care to protect chil...

Page 7: ...ile the power plug is connected to the socket Follow instructions to avoid malfunction or fire Do not use bug repellent or other spray products on the air purifier They can be harmful and may cause electric shock fire or malfunction Do not submerge the air purifier Follow instructions to avoid malfunction Do not handle the product with wet hands Follow instructions to avoid electric shock This app...

Page 8: ...ters They cannot be used again by washing them with water NOTE After replacing a replacement filterwith a new one dispose of the old one in a waste bag as general waste Use only Samsung authorized filters Use of non authorized filters may void product warranty When purchasing a replacement filter be sure to check whether it is the same type of filter Package Content DB68 08449A 03_IB_ACR AX9500_AA...

Page 9: ...let Rear panel 03 Laser PM sensor 04 Gas sensor 05 Dust collecting filter 06 Deodorization filter 07 Pre filter Front side 03 01 02 04 At a Glance 01 Buttons 02 Air outlet Front panel 03 Display 04 Handle both bottom sides Rearside 05 01 AX300T9080W AX300T9080S Removable sticker 03 04 06 02 07 DB68 08449A 03_IB_ACR AX9500_AA_EN indd 9 2020 11 27 오후 6 10 11 ...

Page 10: ...10 PM2 5 PM1 0 concentration display NOTE PM10 Dust in the airwith a diameterof10 orless Fine particles with about 1 5 of the diameter of a human hair PM2 5 Dust in the airwith a diameterof 2 5 orless Fine particles with about 1 20 of the diameter of a human hair PM1 0 Dust in the airwith a diameterof1 0 orless Fine particles with about 1 50 of the diameter of a human hair Diameter of a human hair...

Page 11: ...he product will not work if you do not slide the power adapter all the way in Caution Make sure that no damage is caused to the adapter Do not use a damaged adapter Follow instructions to avoid electric shock or fire Disconnecting the poweradapter Disconnect the power adapter from the product as shown in the figure Before combining or decombining products be sure to disconnect their power adapters...

Page 12: ... one be sure to remove the vinyl packaging STEP1 Open the rear panel Put your fingers in both grooves at the top of the rear panel and then pull it forward STEP 2 Remove the pre filter STEP 3 Remove and discard the protective foam STEP 4 Remove the deodorization filter DB68 08449A 03_IB_ACR AX9500_AA_EN indd 12 2020 11 27 오후 6 10 12 ...

Page 13: ...ove the vinyl packaging from the deodorization filter and the dust collecting filter And also remove the black cloth inside the vinyl packaging of the deodorization filter Deodorizationfilter Dustcollectingfilter DB68 08449A 03_IB_ACR AX9500_AA_EN indd 13 2020 11 27 오후 6 10 12 ...

Page 14: ...ide the grooves at the bottom Check direction of the filters before inserting STEP 2 Insert the deodorization filter STEP 3 Insert the pre filter Insert the hooks on the filter into the grooves on the bottom of the product then slightly push against the unit DB68 08449A 03_IB_ACR AX9500_AA_EN indd 14 2020 11 27 오후 6 10 12 ...

Page 15: ... replacement reminder When the filters are saturated with surrounding odors and thus smell replace them with new ones and then reset the filter replacement reminder NOTE Keep the windows and doors closed wheneveryou can while the product is running Ventilate the air regularly to avoid high concentration of carbon dioxide when you keep the room enclosed for a duration of time When the filters have ...

Page 16: ...ll ventilated space at the High fan speed for4 hours ormore ordry the filters in the sunlight for4 hours ormore This can help remove odors from the filters If the filters smell when you operate the product it means that it is time to replace them because they are saturated with surrounding odors Replace the filters with new ones The filters are a consumable part andwill not be replaced free of cha...

Page 17: ...litylevel remains the same fora specific period of time during operation All indicators and displays except for the cleanliness colorindicators turn off and the product enters the Energysaving mode This does not applywhen using the product in Sleep mode Controlling the fan speed Usethebuttontoselecttheintensityofairflowtopurifytheindoorair Press the button to select the fan speed you want Each tim...

Page 18: ...ff In the Sleep mode the front panel is closed the front display is turned off and only the powerindicatorlights up Changing the fan speed when Sleep mode has been active for10 seconds or more will cancel the mode and the sensor loading display will appear See Sensor loading display on page 17 Cancel Press and hold the button for 3 seconds or more or press the button Lock Use this feature to lock ...

Page 19: ...or 3 seconds or more to reset the filter replacement reminder Caution If you reset the filterreplacement reminderwhen the filters are not replaced with new ones orwhen no filters are installed in the product filterreplacement reminders may not be displayed normally NOTE If the filters need to be replaced the alert Filter is shown on the display for10 seconds when the poweris turned on 3 sec Turnin...

Page 20: ...ness are each displayed for10 seconds if there is no user input and then PM10 cleanliness automatically continues to be displayed If PM2 5 cleanliness PM1 0 cleanliness or GAS cleanliness is worse than PM10 cleanliness the worst value is displayed When they are all the same PM10 cleanliness is displayed Air quality levels Pollution level PM10 concentration m PM2 5 PM1 0 concentration m Gas polluti...

Page 21: ... of air pollution e g proximity to the building s HVAC orventilation systems or loose window frames The gas pollution reading can be affected by odorous household items such as air fresheners deodorants and detergents If you are using more than one air purifier in the same room the dust concentration reading on each unit may not be same as they affect air circulation The dust concentration reading...

Page 22: ...f this product is combined with a model released previously Combining air purifiers STEP1 Open the module connectoron the bottom product Push and rotate the module connector on the product that will be located at the bottom STEP 2 Disconnect the powerfrom the top product Disconnect the power adapter from the product that will be located at the top In combined products the power is supplied through...

Page 23: ...careful not to drop it STEP 2 Connecting the powerto the decombined product Connect the power adapter to the decombined top product STEP 3 Close the module connector on the bottom product Rotate the module connector on the top of the bottom product NOTE Before using a product alone be sure to rotate the module connector so that it is placed at its original position Handle Used alone Used as combin...

Page 24: ...ducts are combined the alert 2 Only is shown on the display Do not stack products in two stages and apply the powerto each one When stacking products in two stages be sure to combine them using the module connector Failure to do so may result in product falling or damage Do not place an object nearthe combined products that makes it possible for children to climb onto them Failure to do so may res...

Page 25: ...impact may cause the product to fall Do not combine products or use combined products on a table When combining products be sure to put them on the floor and combine them using the module connector Failure to do so may result in product falling or damage or injury Do not place objects on the products when each product is used alone orwhen combined products are used Failure to do so may result in p...

Page 26: ...front panel STEP1 Remove the front panel Hold and pull the front panel forward until it is removed Ifyou have difficultyin removing the front panel because it is closed turn on the power unplug the powercordwhile the front panel is open and then remove the front panel STEP2 Clean and drythe front panel Clean anydirt orforeign substance on the front panel withwaterora soft cloth Aftercleaningwithwa...

Page 27: ...irst with a vacuum cleaner and then rinse the filterwith lukewarm water Cleaning interval 2 weeks when using the product 24 hours every day Caution When cleaning the pre filter rubbing with a brush or a similar tool may damage the superfine fibres Drying the filters Keep the filters in the shade until completely dry and away from direct sunlight DB68 08449A 03_IB_ACR AX9500_AA_EN indd 27 2020 11 2...

Page 28: ... to mobile data or Adaptive Wi Fi is turned on you cannot connect to the network Be sure to turn off these functions before connecting to the network Advanced Switch to mobile data Insert SIM card to use mobile data Advanced Off Off NOTE The setup may differdepending on your smartphone model OS version and manufacturer 3 Checking the Internet connectivity After connecting to Wi Fi check that your ...

Page 29: ...ually or by selecting Scan Select manually Air purifier Samsung Scan Air purifier Samsung Air purifier By device type By device type Select Select 2 Connecting the SmartThings app to your product Follow the instructions displayed on the SmartThings app to connect to your product For information on how to use the SmartThings app select the How To menu on the app NOTE If any pop window appears on the...

Page 30: ...and ask how to connect devices other than your PC such as an air conditioner and an air purifier to the Internet Open Source Announcement The software included in this product contains open source software You may obtain the complete corresponding source code for a period of three years afterthe last shipment of this product by contacting our support team via http opensource samsung com Please use...

Page 31: ...imed on off time no timed on off indications are displayed on your air purifier display Once you set a timed on off time it persists even if you unplug and plug in the power cord of your air purifier Operation functions Touch the buttons forvarious additional functions you want to run settings Check the settings for region mute orfilters You can check the filter replacement time and reset the filt...

Page 32: ...e moving the product When moving the front panel it may make a click or rattle sound depending on the operating environment These sounds are normal motor noises made during zero calibration when moving the front panel When the product is operating a sensor operation sound such as a hissing sound may be emitted When you sleep orwant to rest in a quiet environment select the Sleep mode When the prod...

Page 33: ...s smell due to moisture dry them well in sunlight before using them again Pollution level The pollution level indicatorstays red The pollution level indicatordoes not seem to work Check the sensors foranyforeign substances and clean them if necessary In thewinterseason installing and operating the product forthe first time shortlyafterdeliverymaycause the pollution level to reach 999 m with the in...

Page 34: ...ecessarily cause sensor feedback if the dust particles are bigger than PM10 while they are still filtered and removed from the air The PM10 PM2 5 PM1 0 levels the all same When the air is clean you may not see a difference between the PM10 PM2 5 and PM1 0 levels To check if the sensor is functioning test it by tearing paper by the sensor and or rub them to create some dust This will cause the PM l...

Page 35: ...Appendix 35 English Memo DB68 08449A 03_IB_ACR AX9500_AA_EN indd 35 2020 11 27 오후 6 10 17 ...

Page 36: ...0 SAMSUNG 726 7864 1 844 SAM PAYS 726 7297 www samsung com us support CANADA 1 800 SAMSUNG 726 7864 1 844 SAM PAYS 726 7297 www samsung com ca support English www samsung com ca_fr support French QUESTIONS OR COMMENTS DB68 08449A 03_IB_ACR AX9500_AA_EN indd 36 2020 11 27 오후 6 10 17 ...

Reviews: