Duct Type Series

Silhouette duct : AVMDH



High static pressure duct : AVMHH



System Air Conditioner 

DB98-05587A(3)

S

E

F

AVXDD_E_05587A-3.indd   17

2007-04-02   ¿ÀÀü 9:01:34

Summary of Contents for AVMDH

Page 1: ...ENGLISH ESPAÑOL FRANÇAIS USER SMANUAL Duct Type Series Silhouette duct AVMDH High static pressure duct AVMHH System Air Conditioner DB98 05587A 3 S E F ...

Page 2: ...RING YOUR AIR CONDITIONER Safety Precautions 3 View of the Indoor Unit 8 RECOMMENDATIONS FOR USE Operating Recommendations 10 Temperature and Humidity Ranges 11 CleaningYour Air Conditioner 12 Solving Common Problems 14 ...

Page 3: ...ch and circuit breaker only for air conditioner Use the rated current fuse REGARDING POWER SOURCE Do not bend the electric wire by force or weigh down the air conditioner not to be out of order Use the power source with separate wiring only for air conditioner If the power plug is damaged replace it by the manufacturer or qualified personal to avoid the risk Do not install the air conditioner wher...

Page 4: ... could cause injury Keep children away from the unit If the wireless remote controller is not used for a long time remove the batteries If applicable Never spill any kind of liquid into the unit Should this happen unplug or main switch off the unit and contact an authorized service center When using a wireless remote controller the distance should not be more than 7 meters from the air conditioner...

Page 5: ... the unit consult your dealer If pipes are removed incorrectly refrigerant may blow out and come into contact with your skin causing injury Releasing refrigerant into the atmosphere also damages the environments Install the air conditioner avoiding direct sunlight or heater especially water Install the outdoor unit so as to let the discharged air out properly Avoid a place that may disturb your ne...

Page 6: ...trange noise is heard burning smell or smoke blow REGARDING POWER SOURCE Avoid cold and hot air reaching to person pet or a plant directly for a long time Avoid the water from getting into the air conditioner DURING OPERATION Do not use the air conditioner for a long time in a closed room or in a place where there is a baby or an old person Do not step on the air conditioner or put heavy objects o...

Page 7: ...ensure that they do not play with the appliance Max current is measured according to IEC standard for safety and current is measured according to ISO standard for energy efficiency OTHERS Be sure that the air filter is not to be exposed to direct sunlight Do not clean the air conditioner by spraying water directly or with benzene thinner or alcohol The surface of the heat exchanger is sharp so be ...

Page 8: ...E 8 The figures shown in this instruction may differ from yours depending on the model IndoorUnit AVMDH Air outlet Air inlet Air filter View of the Indoor Unit ...

Page 9: ...E 9 ENGLISH IndoorUnit AVMHH Air outlet Air inlet ...

Page 10: ...he outdoor unit at HEAT mode If this happens The heating operation stops The defrost mode will be triggered automatically for about 10 minutes The steam produced on the outdoor unit in the defrost mode is safe No intervention is required after about 10 minutes the air conditioner operates again normally High indoor and outdoor temperatures If both indoor and outdoor temperatures are high and the a...

Page 11: ...midity levels Water may condense on and drip from the surface of the indoor unit if it is used for a long period Mode OutdoorTemperature IndoorTemperature Indoor Humidity Heating 5 F to 75 F approx 81 F or less Cooling 23 F to 109 F approx 64 F to 90 F approx 80 or less Drying 23 F to 109 F approx 64 F to 90 F approx Temperature and Humidity Ranges If the heating operation is used at below 32 F ou...

Page 12: ...ir filter 2 Pull out the air filter 3 Remove all dust on air filter with a vacuum cleaner or a brush In case of serious dust accumulation put the air filter in warm detergent water and shake it vertically 4 After washing allow them to dry throughly in an area protected from sunlight 5 When you have finished insert the filter into the unit 6 Return the levers Note After cleaning the air conditioner...

Page 13: ...air filter in warm detergent water and shake it vertically 4 After washing allow them to dry throughly in an area protected from sunlight 5 When you have finished insert the filter into the unit 6 Reinstall the fixing bracket Note After cleaning the air conditioner press the Filter Reset button To control indoor unit with wireless remote controller you should install a receiver and display unit Wir...

Page 14: ...roller does not operate Check if the battery is discharged Replace the battery Check if the remote controller sensor is blocked Check if the air conditioner is placed near strong light The wired remote controller does not operate Check if is displayed on the wired remote controller Turn off the air conditioner and switch off the circuit breaker Contact the service center The Timer is not set Check...

Page 15: ...E 15 ENGLISH Memo ...

Page 16: ... latin EL SALVADOR 800 6225 www samsung com latin GUATEMALA 1 800 299 0013 www samsung com latin JAMAICA 1 800 234 7267 www samsung com latin PANAMA 800 7267 www samsung com latin PUERTO RICO 1 800 682 3180 www samsung com latin REP DOMINICA 1 800 751 2676 www samsung com latin TRINIDAD TOBAGO 1 800 7267 864 www samsung com latin VENEZUELA 1 800 100 5303 www samsung com latin COLOMBIA 01 800011211...

Reviews: