Samsung AVMCC052CA0 Owner'S Instructions Manual Download Page 1

ENGLISH

OWNER’S INSTRUCTIONS
MANUAL DE INSTRUCCIONES
MANUEL D’UTILISATION

ESP

AÑOL

FRANÇAIS

System Air Conditioner

Aire acondicionado sistemático 

Climatiseur numérique multifonctionnel 

E S F DB98-05586A(2)

AVMCH052CA0(1,3,4)
AVMCH072CA0(1,3,4)
AVMCH105CA0(1,3,4)
AVMCH128CA0(1,3,4)
AVMCH140CA0(1,3,4)

Heat pump

AVMCC052CA0(1,3,4)
AVMCC072CA0(1,3,4)
AVMCC105CA0(1,3,4)
AVMCC128CA0(1,3,4)
AVMCC140CA0(1,3,4) 

Cooling only

Summary of Contents for AVMCC052CA0

Page 1: ...Conditioner Aire acondicionado sistemático Climatiseur numérique multifonctionnel E S F DB98 05586A 2 AVMCH052CA0 1 3 4 AVMCH072CA0 1 3 4 AVMCH105CA0 1 3 4 AVMCH128CA0 1 3 4 AVMCH140CA0 1 3 4 Heat pump AVMCC052CA0 1 3 4 AVMCC072CA0 1 3 4 AVMCC105CA0 1 3 4 AVMCC128CA0 1 3 4 AVMCC140CA0 1 3 4 Cooling only ...

Page 2: ... distance should not be more than 7 meters from the air conditioner If applicable WARNING DURING OPERATION Never store or ship the air conditioner upside down or sideways to avoid damage to the compressor The appliance is not intended for use by young children or infirm persons without supervision Young children should be supervised to ensure that they do not play with the appliance Max current is...

Page 3: ...troller Buttons and Display 6 Wired Remote Controller Buttons and Display 7 Centralized Controller 8 RECOMMENDATIONS FOR USE Operating Recommendations 9 Temperature and Humidity Ranges 10 Cleaning Your Air Conditioner 11 Bio Pure Filter Installation Optional 12 Solving Common Problems 13 TECHNICAL SPECIFICATIONS ...

Page 4: ...lle Indoor Unit TYPE A Indoor Unit TYPE B Timer indicator Remote control sensor On Off button On Off indicator Fan indicator Removing frost indicator Filter Sign indicator Air flow blades outlet Air inlet Air filter under the grille Timer indicator Remote control sensor On Off button On Off indicator Fan indicator Removing frost indicator Filter Sign indicator ...

Page 5: ...Air outlet Connection valve TYPE D Outdoor Unit Air outlet Connection valve TYPE E Outdoor Unit If the heat exchanger in the outdoor unit gets dusty cooling efficiency may fall So clean the heat exchanger with water when it becomes dirty However be careful when you wash the surface of the heat exchanger because it is very sharp N N N No o o ot t t te e e e ...

Page 6: ...selection button Filter Reset button Swing button On Timer button Off Timer button On Off Timer Set Cancel button Fan speed adjustment button Temperature adjustment buttons Temperature setting Fan speed Air flow direction On Timer setting Off Timer setting Battery discharge indicator The wireless remote controller is an optional accessory To use the wireless remote controller refer to an appropria...

Page 7: ... filter refer to page 11 The heating mode is not selected in cooling only models N N N No o o ot t t te e e e Communication error indicator On Timer setting Off Timer setting Test indicator On Timer button Off Timer button Test button Filter Reset button Mode selection button Temperature adjustment buttons Centralized controller indicator In case of installing the Centralized controller Removing f...

Page 8: ...the wall To use the centralized controller refer to an appropriate manual Operating lamp All On button All Off button On Off indicators On Off buttons Index Operating lamp comes on when at least one air conditioner connected to the centralized controller is operating N N N No o o ot t t te e e e E 8 ...

Page 9: ... may form on the outdoor unit at HEAT mode If this happens The heating operation stops The defrost mode will be triggered automatically for about ten minutes No intervention is required after about ten minutes the air conditioner operates again normally Frost If both indoor and outdoor temperatures are high and the air conditioner is running at HEAT mode the outdoor unit s fan and compressor may s...

Page 10: ...ense on and drip from the surface of the indoor unit if it is used for a long periods High humidity levels Mode Outdoor Temperature Indoor Temperature Indoor Humidity Heating Cooling Drying 5 F to 75 F approx 23 F to 109 F approx 23 F to 109 F approx 81 F or less 70 F to 90 F approx 70 F to 90 F approx 80 or less E 10 The standardized temperature for heating is 45 F If the outdoor temperature drop...

Page 11: ...the air filter 5 When you have finished insert the filter into the front grille 6 Clean the unit with a vacuum cleaner or a brush once a month 7 Reinstall the front grille and the safety clips 8 IMPORTANT You must give attention when disassembling the front grille and must check the safety clips have been installed If you do not check them the front grille will drop suddenly and you will be hurt I...

Page 12: ...the bio pure filter with four screws 6 Reinstall the air filter the front grille and the safety clips 7 Do not remove the packing from a bio pure filter until you wish to use the filter as it will lose its properties N N N No o o ot t t te e e e The air conditioner can be fitted with a Bio Pure filter to remove minute dust particles The service life of the filter is approximately three months depe...

Page 13: ... been selected The room temperature may be too low or too high Dust may be blocking the air filter guard refer to page 11 for cleaning instructions Check that there is no obstacle in front of the outdoor unit The air conditioner does not operate with the remote controller Wireless Remote Controller Wireless Remote Controller No beep is heard when you press ON OFF on the remote controller The air c...

Page 14: ...cations Power Supply Model 1Ø 208 230V 60Hz AVMCH052CA0 1 3 4 AVMCH072CA0 1 3 4 AVMCH105CA0 1 3 4 AVMCH128CA0 1 3 4 AVMCH140CA0 1 3 4 AVMCC052CA0 1 3 4 AVMCC072CA0 1 3 4 AVMCC105CA0 1 3 4 AVMCC128CA0 1 3 4 AVMCC140CA0 1 3 4 ...

Page 15: ...E 15 ENGLISH Memo ...

Page 16: ...ELECTRONICS THIS AIR CONDITIONER IS MANUFACTURED BY ESTE AIRE ACONDICIONADO HA SIDO FABRICADO POR CE CLIMATISEUR EST FABRIQUE PAR ...