Samsung AR12HCFN Series User & Installation Manual Download Page 1

A3050 CB&XL&CH_IB&IM_DB68-04138A_HP&CO_EN.indd   1

2013-12-28   14:43:32

Summary of Contents for AR12HCFN Series

Page 1: ...A3050 CB XL CH_IB IM_DB68 04138A_HP CO_EN indd 1 2013 12 28 14 43 32 ...

Page 2: ...by adjusting the maximum operating capacity of the compressor Easy Filter There is no grille to remove before separating the filter from the air conditioner Therefore filter can be cleaned easily more frequently Frequent filter cleaning will prevent dust from entering into the product or accumulating on the filter Smart Install When the installation is done your product will examine itself through...

Page 3: ...ion plate 34 Disassembling Assembling the Cover panel for indoor unit installation 35 Connecting the assembly cable 37 Installing and connecting the assembly pipe of the indoor unit 39 Evacuating the indoor unit 40 Cutting or extending the pipe 40 Installing and connecting the drain hose of the indoor unit 42 Changing direction of the drain hose 43 Installing and connecting the drain hose of the o...

Page 4: ... power line with the power specifications of the product or higher and use the power line for this appliance only In addition do not use an extension line Extending the power line may result in electric shock or fire Do not use an electric transformer It may result in electric shock or fire If the voltage frequency rated current condition is different it may cause fire The installation of this app...

Page 5: ...r problems with the product Install the draining hose properly so that water is drained correctly Failing to do so may result in water overflowing and property damage Avoid adding drain to waste pipes as odours may arise in the future When installing the outdoor unit make sure to connect the draining hose so that draining is performed correctly The water generated during the heating operation by t...

Page 6: ...nter Failing to do so may result in problems with the product water leakage electric shock or fire A delivery service for the product is not provided If you reinstall the product in another location additional construction expenses and an installation fee will be charged Especially when you wish to install the product in an unusual location such as in an industrial area or near the seaside where i...

Page 7: ... WARNING Do not place an object near the outdoor unit that allows children to climb onto the machine This may result in children seriously injuring themselves Do not use this air conditioner for long periods of time in badly ventilated locations or near infirm people Since this may be dangerous due to a lack of oxygen Open a window at least once an hour If any foreign substance such as water has e...

Page 8: ... appliance with wet hands This may result in electric shock Do not spray volatile material such as insecticide onto the surface of the appliance As well as being harmful to humans it may also result in electric shock fire or problems with the product Do not drink the water from the air conditioner The water may be harmful to humans Do not apply a strong impact to the remote controller and do not d...

Page 9: ...ric shock or fire Before cleaning or performing maintenance cut off the power supply and wait until the fan stops Failing to do so may result in electric shock or fire FOR CLEANING CAUTION Take care when cleaning the surface of the heat exchanger of the outdoor unit since it has sharp edges This should be done by a qualified technician please contact your installer or service center Do not clean t...

Page 10: ... actuated to help remove frost from an outdoor unit that may have deposited at low temperatures The internal fan is switched off automatically and restarted only after the defrost cycle is completed AR HP Type Description Against cold air AR HP The internal fan will be off to prevent cold air when the heat pump is heating Defrost cycle AR HP The internal fan will be off to defrost ice when the hea...

Page 11: ... Checking the name of the parts Display Power button Remote controller receiver Air filter Air flow blade upanddown Air flow blade leftandright Air intake Single user indicator Timer Auto clean indicator Power indicator English 11 PREPARATION 01 A3050 CB XL CH_IB IM_DB68 04138A_HP CO_EN indd 11 2013 12 28 14 43 33 ...

Page 12: ...ferent fan speeds such as Auto Low Medium High Turbo Cancel Cancel the timer mode Beep off To silence the beep sound when pressing the button Vertical air swing Activate Deactivate air flow blade movement automatically up and down Set the mode on Mode Set one of the 5 operating modes see pages 14 15 for instructions Auto Clean Auto clean function Dry inside of the indoor unit to get rid of odor Po...

Page 13: ...he batteries 1 Push the lever as arrow indicates on the rear side of the remote controller and pull up 2 Insert two AAA batteries Check and match the and signs accordingly Make sure you have inserted the batteries in correct position 3 Close the cover by place it back to its original position You should hear click sound when the cover is locked properly Fast Comfort indicator Set temperature indic...

Page 14: ...desired coolness Dry The air conditioner in Dry mode acts like a dehumidifier by removing moisture from the indoor air Dry mode makes the air feel refreshing in a humid climate To activate the Dry mode set temperature on the remote controller should be lower than indoor room temperature Fan Fan mode can be selected to circulate your room Fan mode will be helpful to refresh the stale air in your ro...

Page 15: ...y Auto Fan Low Med High Turbo Heat AR HP Auto Low Med High Turbo Press the button to adjust the temperature Auto 2 Step Cooling or Heat AR HP You can adjust the desired temperature by 1 C within the range of 16 C 30 C Cool You can adjust the desired temperature by 1 C within the range of 16 C 30 C Dry You can adjust the desired temperature by 1 C within the range of 18 C 30 C Fan Temperature adjus...

Page 16: ...e completely when you turn off the air conditioner Adjusting the air flow direction is not available in good sleep mode while it is in cool mode However you can adjust the air flow direction in good sleep mode while it is in heat mode AR HP Horizontal air flow Make sure one of the blade pin lever that stick out of the air flow blades are not broken Move the blade pin lever left or right to keep th...

Page 17: ...e Comfort function Press the Fast Comfortbutton twice when the Fast function is on Cancel You can set the Comfort function to provide mild cooling Comfort function is only available in Cool mode If you press the Mode button while the Comfort function is on it will cancel the function You can adjust the temperature but fan speed cannot be adjusted when the function is on Press the Fast Comfortbutto...

Page 18: ...peed will be adjusted automatically according to the mode However I f you select mode while heating operation is on you can adjust fan speed AR HP When the mode is on In Cool mode Air flow direction will be adjusted automatically In Heat mode Adjusting air flow direction is available AR HP 1 Press the button on the remote controller indicator appears and Off timer indicator starts blinking on the ...

Page 19: ...ing and reserved time will be displayed for 3 seconds If you don t press Set button within 10 seconds after selecting the time the air conditioner will return to previous status Check On timer or Off timer indicator on the remote controller display and indicator on the indoor unit AdditionaloptionsavailableinOntimermode You can select from Auto Cool Dry Fan Heat AR HP You can adjust the temperatur...

Page 20: ... heat AR HP Heat AR HP Fan mode approximately 15 minutes CombiningOnTimerandOffTimer Iftheairconditionerison Iftheairconditionerisoff PresettimeonOntimerislongerthanOfftimer Ex On timer 3 hours Off timer 1 hour The air conditioner will operate the Off timer after 1 hour from the moment you have set the timer Your air conditioner will turn on after 2 hours PresettimeonOntimerisshorterthanOfftimer E...

Page 21: ...hen Single User function is activated in Cool mode temperature range will be limited to 24 C 30 C If the desired temperature is lower than 24 C in Cool mode turn off the Single User function by pressing the SingleUser button again Temperature Fan speed can also be adjusted see page 15 for instructions Air flow can be adjusted see page 16 for instruction If you press the Mode button while the Singl...

Page 22: ...ld use a micro fiber cloth to clean the panel When you use the micro fiber cloth slightly dampen the cloth and remove any debris on the cloth to avoid scratches Heatexchanger Illustration may differ slightly depending on the models Make sure to turn off the power of the indoor unit and cut off the power supply before cleaning the air conditioner CAUTION Do not clean the display using alkaline dete...

Page 23: ...ve the Air filter from the main body Insert the Air filter back in its original position Dry the Air filter in a ventilated area Clean the Air filter with a vacuum cleaner or soft brush If dust is too heavy rinse it with running water Clean the Air filter every 2 weeks Cleaning term may differ depending on the usage and environmental conditions In dusty area clean it once a week If the Air filter ...

Page 24: ...op of the Air filter into the the main body Air filter 2 There s one hook in both side of the filter press the surface of the Air filter softly and get the hooks into the main body 3 Press the bottom of the filter lightly to securely fix the main body English 24 A3050 CB XL CH_IB IM_DB68 04138A_HP CO_EN indd 24 2013 12 28 14 43 40 ...

Page 25: ...n 2 Thoroughly clean the heat exchanger 2 Clean the cross fan 2 Clean the condensate drain pipe 2 Replace the remote controller batteries 1 Outdoor unit Clean the heat exchanger on the outside of the unit 2 Clean the heat exchanger on the inside of the unit 2 Clean the electric components with jets of air 2 Verify that all the electric components are firmly tightened 2 Clean the fan 2 Verify that ...

Page 26: ...eisalotofdust ontheAirfilter cooling heating AR HP performancemay decrease Cleanthemfrequently Checkiftheoutdoorunitiscoveredorinstalledneartheobstacle Takethecoveroffandtaketheobstacleaway Checkiftheairconditionerisoperatingindefrostmode Whenthe iceformedinwinterortheoutdoortemperatureistoolow the airconditioneroperatesindefrostmodeautomatically Indefrost mode indoorfanstopsandwarmairdoesnotcomeo...

Page 27: ...er Odorspermeatein theroomduring operation Checkiftheapplianceisrunninginasmokyarea Ventilatethe roomoroperatetheairconditionerinFanmodefor1 2hours Wedonotusesmellycomponentsintheairconditioner ChecktheDrainshavebeenclearedRegularMaintenance Errorisindicated Whenanindoorunitindicatorblinks contactthenearestservice center Pleaseensuretheerrorcodeispassedontotheservice centerwhenbookingtheservicecal...

Page 28: ...used for laundry Do not use the units if damaged If problems occur switch the unit off and disconnect it from the power supply In order to help prevent electric shocks fires or injuries always stop the unit disable the protection switch and contact SAMSUNG s technical support if the unit produces smoke if the power cable is hot or damaged or if the unit is very noisy Always remember to inspect the...

Page 29: ... power supply comply with the specifications and that the installed power is sufficient to ensure the operation of any other domestic appliance connected to the same electric lines Always verify that the cut off and protection switches are suitably dimensioned Verify that the air conditioner is connected to the power supply in accordance with the instructions provided in the wiring diagram include...

Page 30: ...han 2 4 m or directly under eaves for accessibility for service and OH S reasons Avoid the following places to prevent malfunction of the unit Where there is machine oil Salty environment such as seaside areas Where sulfide gas exists Other special atmosphere areas 125 mm or more 300 mm or more 125 mm or more 600 mm minimum 300 mm minimum 300 mm minimum 600 mm minimum L meters maximum total pipe l...

Page 31: ...e upper part of the outdoor unit and the air outlet is opposite the wall When the walls are blocking front and the rear side of the outdoor unit 300 or more 1500 or more Top view Side view Air outlet Air intake Air intake Air outlet Figure Description Air flow direction Unit mm When installing more than 1 outdoor unit Unit mm 1500 or more When the air outlet is towards the wall When 3 sides of the...

Page 32: ...rate sound and cause bad effect on the product Installation must be done in level and in a place where vibration will not cause any effect The following accessories are supplied with the air conditioner The number of each accessory is indicated in parentheses Accessories in the indoor unit case Accessories Unit mm Installation Plate 1 09 12 03 frame AR18HP 04 frame Installation Plate 1 AR18HC 24 0...

Page 33: ...r Pipe Bender Spirit Level Screw Driver Spanner Drill LWrench MeasuringTape Tools for test operations Thermometer Resistance Meter Electroscope Optional accessories The following connection accessories are optional If they are not supplied you should obtain them before installing the air conditioner If these accessories are supplied they will be in the accessory box Insulated Assembly Pipe Ø6 35mm...

Page 34: ... window frame 2 Attach the wooden uprights to the window frame giving attention to the weight of the indoor unit 3 Attach the installation plate to the wooden upright using tapping screws If you fix the indoor unit on a gypsum board 1 Use stud finder to find out locations of the studs 2 Fix the plate hanger on two studs If you mount the plate to a concrete wall using plastic anchors make sure that...

Page 35: ...semble the cover panel Cap Screw Remove the Cap screw Unfasten the screw Cover Panel Removing the Cover panel Before mounting the indoor unit Cover panel is fixed to a main body of the product with hooks on two sides and central part as shown in the illustration Release the hooks on the sides first and then release the hooks on the central part Check the location of the hooks before removing the c...

Page 36: ...the indoor unit To assemble the Cover panel proceed in reverse order of disassembling Use both hands for assembling and be extra careful not to damage the pipes and drain hose Fix the hooks on the side and central part Then fasten the screws and assemble the Cap screws Fix the hooks on side parts Fasten the screw Fixthehooksoncentralpart Assemble the Cap screw Disassembling AssemblingtheCoverpanel...

Page 37: ... not connect two or more different cables to extend the length It may cause fire When you install the unit make first refrigerant connections and then electrical connections Connect the air conditioner to grounding system before performing the electrical connection If unit is uninstalled first disconnect electrical cables then refrigerant connections If the outdoor unit is more than 4 or 5 meters ...

Page 38: ...ers on the indoor outdoor unit matches Please ensure that Power Communication cables are separated they must not be in the same cable 10 Connect the grounding conductor to the grounding terminals 11 Close the terminal board cover by tightening the screw carefully In Russia and Europe consult with the supply authority to determine the supply system impedance before installation Connect the wires fi...

Page 39: ...r the refrigerant pipe varies according to the exit position of the pipe when facing the wall Right A Left B Underside C Rear B A C Outer Diameter Torque N m kgf cm ø6 35 mm 14 18 140 180 ø9 52 mm 34 42 350 430 ø12 70 mm 49 61 500 620 ø15 88 mm 68 82 690 830 If you want to shorten or extend the pipes refer to page 40 41 4 Cut off the remaining foam insulation 5 If necessary bend the pipe to fit al...

Page 40: ... pipe longer than 4 or 5 meters You must add refrigerant to the pipes otherwise the indoor unit may freeze Cutting or extending the pipe 1 Unscrew the caps at the end of each pipe All inert gas exhausts from the indoor unit The indoor unit is supplied with inert gas nitrogen Before installing the unit check if nitrogen gas flow out of indoor unit If this one isn t true DO NOT INSTALLTHE UNIT since...

Page 41: ...r further details on how to connect to the outdoor unit and evacuate the air refer to page 44 46 Correct Uneven Thickness Cracked Damaged Surface Inclined Excessive torque can be cause of gas leakage If extending pipe by welding brazing please ensure nitrogen is used during welding brazing process The joint must be accessible and serviceable Tighten the flare nut with torque wrench according to sp...

Page 42: ...lamp 4 When extending the Drain Hose hold the end of Drain Hose and Extended Hose rotate and insert the drain hose into Extended hose for 40 45 mm Make sure the two hoses are firmly connected there is no water leakage 5 Connect the Drain Hose after using Foam Insulation to wrap the Extended Hose Then Use vinyl tape to wrap the each side of connection by 20 mm If you do not use the other drain hose...

Page 43: ... does not overflow onto the electrical part Change the direction only when it is necessary 1 Detach the rubber cap with the pliers 2 Detach the drain hose by pulling it and turning to the left 3 Insert the drain hose by fixing it with the screw into the groove of the drain hose and the outlet of the drain pan 4 Attach the rubber cap with a screwdriver by turning it to the right until it fixes to t...

Page 44: ...oid this incident install a frame that is higher than estimated snow fall In addition install a snow proof hood to avoid snow from piling on the outdoor unit When installing make sure there is no leakage When recovering the refrigerant ground the compressor first before removing the connection pipe If the refrigerant pipe is not properly connected and the compressor works with the service valve op...

Page 45: ... the low pressure side of manifold gauge clockwise Turn off the vacuum pump Check for 2 minutes if there is any pressure change Remove the hose of the low pressure side of manifold gauge 6 Set a valve cork of liquid and gas service port to the open position Vacuum Pump Manifold gauge Valve Gas service port Low pressure Liquid service port High pressure Backward flowing prevention The remaining air...

Page 46: ...crew 7 16 20UNF R 410A Diameter of the screw 1 2 20UNF Tightening torque for charging port cap Refer to the table Test part for indoor unit Before inspecting the leakage use a torque wrench to close the cap for the service valve Comply with a tightening torque for each size of the diameter and tighten the cap firmly to prevent any leakage To check for any possible leakage insert inert gas into the...

Page 47: ...he unit to let the discharged air out properly 2 Fix the outdoor unit in level to an appropriate support using anchor bolts 3 If the outdoor unit is exposed to strong winds install shield plates around the outdoor unit so that the fan can operate correctly 5 Wrap the rest of the pipe with vinyl tape 6 Attach the pipe to the wall using clamps optional Installation plate Connecting wires Connecting ...

Page 48: ...ired for pipe extension 2 Status of the indicator after supplying the power Standby status 2 When the air conditioner is in standby status use the remote controller to start the Smart Install mode 1 Press the Set Cancel or Cancel Mode Power button simultaneously for 4 seconds f f Smart Install mode can be operated only with the supplied remote controller f f During the Smart install mode procedure...

Page 49: ...ary measures when error occurs Refer to the service manual for necessary measures for each error that occurs 2 Use the product after taking care of the error that occurs Error indicator Error Measures to take by an installer Display LED Display LED 1 LED 2 LED 3 Error on indoor temperature sensor 1 Check the connection of the connector Error on indoor heat exchanger 1 Check the connection of the c...

Page 50: ...ck Inlet air temp Outlet air temp From 10 C to 12 C indicative deltaT Heating mode indoor unit check AR HP Outlet air temp Inlet air temp From 11 C to 14 C indicative deltaT In heating mode the indoor fan motor can remain off to avoid cold air blown into conditioned space AR HP Approximately 3 5 minutes later outdoor unit will start to operate and the Cool orWarm AR HP air will blow out After 12 m...

Page 51: ...ce and position your contraction tube in the middle of the insulation tape 5 Apply heat to the contraction tube to contract it 6 After tube contraction work is completed wrap it with the insulation tape to finish Tools Crimping pliers Connectionsleeve mm Insulation tape Contractiontube mm Spec MH 14 20xØ7 0 HxOD Width 18 mm 50xØ8 0 LxOD Shape 40 mm Insulation tape Contraction tube Unit mm 120 60 2...

Page 52: ...ng com latin_en English DOMINICA 1 800 751 2676 www samsung com latin Spanish www samsung com latin_en English ECUADOR 1 800 10 7267 www samsung com latin Spanish www samsung com latin_en English ELSALVADOR 800 6225 www samsung com latin Spanish www samsung com latin_en English GUATEMALA 1 800 299 0013 www samsung com latin Spanish www samsung com latin_en English HONDURAS 800 27919267 www samsung...

Page 53: ...sung com register This manual is made with 100 recycled paper AR HCFS Series AR HPFS Series AR HCFN Series Air Conditioner user installation manual imagine the possibilities ThankyouforpurchasingthisSamsungproduct To receive more complete service please register your product at www samsung com register This manual is made with 100 recycled paper A3050 CB XL CH_IB IM_DB68 04138A_HP CO_EN indd 53 20...

Reviews: