Summary of Contents for AQV09N Series

Page 1: ... Heating S E F ESPAÑOL FRANÇAIS USER SMANUAL AQV09N Series AQV12N Series AQV18N Series AQV24N Series DB 8 81A Air Marketing Group LLC 141 Kinderkamack Rd Park Ridge NJ 07656 Tel 201 782 1782 Fax 201 782 1783 Web www amgair com Email info amgair com ...

Page 2: ...plier and check the terms and conditions of the purchase contract This product should not be mixed with other commercial waste for disposal PreParation Safety Precautions 3 Name of Each Part 8 Remote Control Buttons and Display 10 Inserting the Remote Control Batteries 11 Getting Started 1 oPeration Selecting Auto Mode 13 Selecting Cool Mode 14 Selecting Heat Mode 15 Selecting Dry Mode 16 Selectin...

Page 3: ...allationmanualinahandyplacesothatyoucanfinditwhenever youneedtoseeitafterreadingthismanualthoroughly WARNING This indicates the possibility of serious injury or death CAUTION This indicates the possibility of serious injury or damage to environments when operated incorrectly Do not install the unit in a place where it is exposed to inflammable gas leakage Do not install the outdoor unit where ther...

Page 4: ... not be more than 7 meters from the air conditioner If applicable Do not place any materials so that children cannot step on it Do not connect the electric heater to the air conditioner or repair it with your discretion The manufacturer declines any liability for damage resulting from modifications or errors in the electrical or hydraulic connections Do not insert anything between the air outlet b...

Page 5: ...ments Please recycle or dispose of the packaging material for this product in an environmentally responsible manner diSPoSing the unit WARNING Install the air conditioner avoiding direct sunlight or heater especially water Install the outdoor unit so as to let the discharged air out properly Avoid a place that may disturb your neighbor by noise Install the drain hose to let the water run safely an...

Page 6: ...ont grille during operation Avoid cold and hot air reaching to person pet or a plant directly for a long time Avoid the water from getting into the air conditioner duRing oPeRation Do not use the air conditioner for a long time in a closed room or in a place where there s a baby or an old person Do not step on the air conditioner or put heavy object on it Do not drink the water from the air condit...

Page 7: ...osed to direct sunlight Do not clean the air conditioner by spraying water directly or with benzene thinner or alcohol The surface of the heat exchanger is sharp so be careful of it when cleaning Turn off the air conditioner and if the fan stops to operate clean the air conditioner Clean the air filter every weeks Be sure to insert the air filter When opening or closing the front panel use a stabl...

Page 8: ... the grille Air flow blades outlet Air Inlet Temperature sensor Power On Off button Operation indicator GREEN Timer indicator GREEN Turbo indicator RED Power On Off button Air Marketing Group LLC 141 Kinderkamack Rd Park Ridge NJ 07656 Tel 201 782 1782 Fax 201 782 1783 Web www amgair com Email info amgair com ...

Page 9: ...let Rear Outdoor Unit AQV0 N Series AQV1 N Series Outdoor Unit AQV18N Series AQV 4N Series The design and shape can be changed according to the model Air Marketing Group LLC 141 Kinderkamack Rd Park Ridge NJ 07656 Tel 201 782 1782 Fax 201 782 1783 Web www amgair com Email info amgair com ...

Page 10: ...ment button Silence mode button Temperature adjustment buttons Temperature setting mode indicator Turbo function indicator Fan speed Silence indicator Air flow direction On Timer indicator Off Timer indicator Battery discharge indicator button Operating mode indicator AUTO COOL DRY FAN HEAT Air Marketing Group LLC 141 Kinderkamack Rd Park Ridge NJ 07656 Tel 201 782 1782 Fax 201 782 1783 Web www am...

Page 11: ... the European Union and other European countries with separate battery return systems This marking on the battery manual or packaging indicates that the batteries in this product should not be disposed of with other household waste at the end of their working life Where marked the chemical symbols Hg Cd or Pb indicate that the battery contains mercury cadmium or lead above the reference levels in ...

Page 12: ...ou have already seen the basic description of the unit on pages from 8 to 10 Starting with the next page you will find a series of step by step procedures for each function available The illustrations in the step by step procedures use three different symbols PRESS PUSH HOLD DOWN Air Marketing Group LLC 141 Kinderkamack Rd Park Ridge NJ 07656 Tel 201 782 1782 Fax 201 782 1783 Web www amgair com Em...

Page 13: ...e The air conditioner changes from Cool or Heat mode automatically depending on the current temperature Note You can change modes at any time 3 Press the button to adjust the temperature until the required temperature is displayed You can set the temperature between 61 F 16 C and86 F 30 C Result Each time you press the button The temperature adjusts by 1 F The indoor unit beeps 4 Press the button ...

Page 14: ...ature between 61 F 16 C and 86 F 30 C Result Each time you press the button The temperature adjusts by 1 F The indoor unit beeps If the room temperature is higher than the selected temperature the air conditioner starts cooling If the room temperature reaches the set temperature the air conditioner stops cooling but the fan continues to operate 4 Press the button to select the fan speed until the ...

Page 15: ...ture adjusts by 1 F The indoor unit beeps If the room temperature reaches F higher than the set temperature the air conditioner stops heating but the fan continues to operate If the room temperature reaches 5 F lower than the set temperature the air conditioner starts heating again 4 Press the button to select the fan speed until the required setting is displayed Automatic rotated Low Medium High ...

Page 16: ...he button The air conditioner runs in the Dry mode Note You can change modes at any time 3 Press the button to adjust the temperature until the required temperature is displayed You can set the temperature between 61 F 16 C and 86 F 30 C Result Each time you press the button The temperature adjusts by 1 F The indoor unit beeps The air conditioner starts dehumidifying and the fan speed adjusts auto...

Page 17: ... on the remote control until is displayed Result The indoor unit beeps each time you press the button The air conditioner runs in Fan mode The temperature can t be set Note You can change modes at any time 3 Press the button to select the fan speed until the required setting is displayed Low Medium High Result Each time you press the button the indoor unit beeps 4 To control the airflow direction ...

Page 18: ...is mode automatically stops after 8 hour operation In the case of adjusting time Press the button to adjust desired operation time from 30 minutes to 1 hours mode will automatically stop after the set time Press the button Result In the case of adjusting the extra time for mode you should press the button within 10 seconds If you do not press the button within 10 seconds mode will automatically st...

Page 19: ...to comfortable crisp air making you feel refreshed and energized Set the Off timer in mode for more than 5 hours Sleep may be disturbed if the mode is set for too short or too long a time because the temperature changes are set to an 8 hour cycle If the mode is set for less than 4 hours the operation will stop at the set time If the mode is set for over 5 hours the last hour will run in Waking Up ...

Page 20: ...and fan settings are adjusted automatically The air conditioner cools or heats the room as quickly as possible After 30 minutes the air conditioner is reset automatically to the previous setting You can select theTurbo function in Auto Cool and Heat mode If you select this function in Dry or Fan mode the mode changes to Auto mode 3 Press the button again to stop the Turbo Function before the end o...

Page 21: ...ton again to stop the blade moving up and down Note If you turn the air conditioner Then the blade Off is closed completely On set to the default position Adjusting the Airflow Direction Horizontally You can adjust airflow direction horizontally manually The inner blades with small fins move the air in the desired direction 1 Adjust the inner blades by moving them left or right Make sure do not to...

Page 22: ... the appointed time and the On Timer setting disappears 3 Press the button until the desired mode is displayed at the top of the remote control to select the mode in advance Result The air conditioner operates in the selected mode when it is turned on To Cancel the On Timer If you no longer wish to use the On Timer that you have set you can cancel it at any time 1 To cancel the On Timer press the ...

Page 23: ...automatically at the appointed time by using On OffTimer during operation you should set the OnTimer longer than the OffTimer Caution Make sure that the air conditioner will not continue to run after OnTimer setting is confirmed Note You can check or change the mode and or the temperature by pressing the button or the button after setting the Off Timer If you would like to turn off the air conditi...

Page 24: ...itable mode for the room temperature The mode may change from cooling into heating from heating into cooling depending on the current temperature during operation RoomTemperature Operating Mode Less than 75 F 4 C Heat 75 F 4 C or above Cool 2 To switch the air conditioner off press the ON OFF switch again Note Even if the air conditioner has been switched on via the ON OFF switch operations can st...

Page 25: ... damp cloth and mild detergent do NOT use benzene solvents or other chemicals Note If you have not used the air conditioner for a long period of time set the fan going for three to four hours to dry the inside of the air conditioner thoroughly Front grille Air filter Body groove Body Front grille Hook Body To remove minute dust particles and odors deodorizing and Bio filter are installed in the ai...

Page 26: ...peration starts up after 3 minutes for the reason of protection Cooling operation The indoor unit may not get the selected fan speed such as Medium and Low under cooling operation at very low outdoor temperatures for the protection of the indoor unit from ice or frost During Low fan speed operation cooling performance will be reduced If the room does not be cooled down when using Low fan speed ope...

Page 27: ...ry mode the fan speed is selected automatically The remote control does not operate Check if the battery is discharged Replace the battery Check if the remote control sensor is blocked Check if the air conditioner is placed near strong light The Timer is not set Check if you pressed the button after selecting time Odor is permeated in the room during operation Check if you use the air conditioner ...

Page 28: ...26 7864 www samsung com ca MEXICO 01 800 SAMSUNG 726 7864 www samsung com mx U S A 1 800 SAMSUNG 726 7864 www samsung com us C Air Marketing Group LLC 141 Kinderkamack Rd Park Ridge NJ 07656 Tel 201 782 1782 Fax 201 782 1783 Web www amgair com Email info amgair com ...