Page 1: ...lmado de Aire Acondicionado Refrigeraci n Climatiseur Monobloc de Type Split Refroidissement OWNER S INSTRUCTIONS MANUAL DE INSTRUCCIONES MANUEL D UTILISATION E S F A DB98 04434A 1 Indoor Unit APC4082...
Page 2: ...use Do not direct air flow at fireplaces or heating apparatus Do not climb on or place objects on the air conditioner Do not hang objects from the indoor unit Do not set flower vases or water containe...
Page 3: ...Cooling Distant Place 13 Removing Excess Humidity 14 Airing Your Room 15 Selecting Energy Saving Mode 16 Cleaning Air in Your Room 17 Adjusting the Air Flow Direction Vertically 18 Adjusting the Air...
Page 4: ...button You can operate the air conditioner with the control panel when you do not wish to or cannot operate the air conditioner with the remote control E 4 To open the grille Hold the upper part of th...
Page 5: ...Air inlet Rear Air outlet Connection valve Outdoor Unit E 5 ENGLISH...
Page 6: ...n Temperature adjustment buttons Extra button Operating mode selection button Cool Auto Dry Fan Air flow swing button On Off timer button Fan speed Auto Low Medium High Timer settings On Off button Fa...
Page 7: ...erating E 7 ENGLISH Front Reset button Press if the digital telecommunicator does not operate normally Telephone cable port Power cable port Back Connection Connect telephone line Telephone jack Line...
Page 8: ...advantage of unit s features The booklet is organized as follows The following figures are shown on pages from 4 to 7 Indoor and outdoor units Remote control buttons and display Digital telecommunicat...
Page 9: ...ot use old batteries or different kinds of batteries together Batteries may be completely discharged after 12 months even if they have not actually been used You must insert or replace the remote cont...
Page 10: ...or unit beeps each time you press the button The air conditioner runs in the Cool mode 2 You can change modes at any time N N N No o o ot t t te e e e To adjust the temperature press the button one or...
Page 11: ...en it is started immediately after being Plugged in Stopped lt will start up normally after three minutes IMPORTANT If the is not displayed at the top of the remote control press the button on the rem...
Page 12: ...m to prevent the unit from being damaged when it is started immediately after being Plugged in Stopped lt will start up normally after three minutes IMPORTANT Press the button Result The air condition...
Page 13: ...the button Result The air conditioner cools the room as far as possible The fan settings are adjusted automatically If you press the button in the Dry or the Fan mode that is changed with the Auto mo...
Page 14: ...tion of the air flow refer to pages 18 19 4 If the is not displayed at the top of the remote control press the button on the remote control one or more times until it appears Result The indoor unit be...
Page 15: ...mally after three minutes IMPORTANT If the is not displayed at the top of the remote control press the button on the remote control one or more times until it appears Result The indoor unit beeps each...
Page 16: ...ving mode If the selected temperature is lower than 25 C it will slowly rise up to 26 C If the selected temperature is higher than 26 C it will slowly rise The outer air flow blade moves up and down 2...
Page 17: ...tioner is turned off 1 Press the button Result The air conditioner starts up in the Clean mode The indoor unit beeps If you wish to stop the Cleaning function press the button again Result The air con...
Page 18: ...ending on the position of the indoor unit your room you can adjust the position of the outer air flow blade on the upper part of the unit thus increasing the efficiency of the air conditioner 1 Press...
Page 19: ...are two sets of air flow blades Just as the outer air flow blade can be adjusted vertically the inner blade can be adjusted horizontally 1 Press the button Result The inner blade moves right and left...
Page 20: ...splayed Possible time is between 0 5 hour and 24 hours inclusive Result Each time you press the button The time is adjusted by 0 5 hour or 1 hour The indoor unit beeps 2 Press the button again To Canc...
Page 21: ...the Off timer indicator stops The air conditioner will turn off automatically when the counter displayed on the remote control reaches the setting time as disappearing the Off timer setting 3 If you...
Page 22: ...sive Result Each time you press the button The time is adjusted by 0 5 hour or 1 hour The indoor unit beeps The air conditioner will turn off automatically when the counter displayed on the remote con...
Page 23: ...ilated before going out The digital telecommunicator does not work if it is connected with the key phones normally used in the office Caution Enter the password 2 The original password is 00 To change...
Page 24: ...or before changing a password Caution Select changing the password by pressing number 8 2 If you forget the password press the RESET button on the back of the digital telecommunicator The password is...
Page 25: ...nditioner can be used If the air conditioner is used at Then The automatic protection feature may be triggered and the air conditioner stopped High temperature A water leakage or some other malfunctio...
Page 26: ...f the breaker for the unit IMPORTANT Remove all dust on the air filter with a vacuum cleaner or brush 2 When you have finished insert the air filter into the original position and close the front gril...
Page 27: ...its properties N N N No o o ot t t te e e e You have to clean the electric dust collector once a month and the cleaning cycle depends on the time during which the air conditioner is used Open the fron...
Page 28: ...low or too high Dust may be blocking the air filter guard refer to pages 26 27 for cleaning instructions Check that there is no obstacle in front of the outdoor unit Check that the operating mode is s...
Page 29: ...Technical Specifications E 29 ENGLISH Model 1 220 240V 50Hz 40000BTU h 3850W 19 5A APC4082E APC4082EC Power supply Capacity Power Dissipation Current...
Page 30: ...ELECTRONICS THIS AIR CONDITIONER IS MANUFACTURED BY ESTE AIRE ACONDICIONADO HA SIDO FABRICADO POR CE CLIMATISEUR EST FABRIQUE PAR Printed in Korea...