background image

safety information

 

_07

Do not touch the pipe connected to the air conditioner.

Install the indoor unit away from lighting apparatus using the ballast.

• 

If you use the wireless remote controller, reception error may occur due to the ballast of 

the lighting apparatus.

Install the outdoor unit where operating noise and vibration will not disturb 

your neighbor and in a well-ventilated area with no obstacle.

• 

Potential risk of malfunction.

• 

Operating noise may disturb your neighbor.

Make sure that there are no obstacles or covers that block the air 

conditioner.
Allow sufficient space for air circulation.

• 

Insufficient ventilation may result in poor performance.

If the power cable is damaged, the manufacturer or a qualified service 

technician must replace it.
If a power outage occurs while the air conditioner is working, turn off the 

power source immediately.
Max current is measured according to IEC standard for safety and current is 

measured according to ISO standard for energy efficiency.
Check for damage on delivery. If damaged, do not install the air conditioner 

and call the place of purchase immediately.
Keep indoor temperatures stable and not extremely cold, especially where 

there are children, elderly or disabled people.
The packaging material and used batteries of the remote controller (optional) 

must be disposed of in accordance with the national standards.
The refrigerant used in the air conditioner must be treated as chemical 

waste. Dispose the refrigerant following national standards.
Have a qualified service technician install the air conditioner and perform a 

trial operation.
Firmly connect the drain hose to the air conditioner for proper water 

drainage.
Check for damages on the outdoor unit installation pad at least once a year.

• 

Potential risk of personal injury or property loss.

When using a wireless remote controller, the distance should not be more 

than 7 meters from the air conditioner.
If the remote controller is not used for a long period of time, remove the 

batteries to prevent leakage of electrolyte.
When cleaning the outdoor unit, touch the heat exchanger radiator fins with 

extreme care.

• 

Wearing thick gloves can protect your hands.

Make sure that the condensed water dripping from the drain hose runs out 

properly and safely.
The appliance is not intended for use by persons (including children) with 

reduced physical, sensory or mental capabilities, or lack of experience 

and knowledge, unless they have been given supervision or instruction 

concerning use of the appliance by a person responsible for their safety:  

Young children should be supervised to ensure that they do not play with the 

appliance. 

AP28N0A_IB_E_31713-1.indd   7

2010-02-10   ソタネト 12:48:03

Summary of Contents for AP30N0A

Page 1: ...ibilities Thank you for purchasing this Samsung product To receive more complete service please register your product at www samsung com global register AP28N0A AP30N0A AP30N1A Pe E DB98 31713A 1 AP28...

Page 2: ...trong Turbo Long Function Your new air conditioner supports Turbo function which makes you cool warm fast for 30 minutes and Long function which makes the cool warm air goes to much further place Look...

Page 3: ...at www samsung com Important safety symbols and precautions WARNING Hazards or unsafe practices that may result in severe personal injury or death CAUTION Hazards or unsafe practices that may result...

Page 4: ...plug power cable or loosened power receptacle Potential risk of fire or electric shock Install an exclusive circuit breaker and short circuit breaker for the air conditioner Potential risk of electric...

Page 5: ...the appropriate measures to prevent the allowable concentration from being exceeded If the refrigerant leaks and cause the concentration limit to be exceeded hazards due to lack of oxygen in the room...

Page 6: ...ectric shock or fire if repairs or installations are attempted by a non qualified service technician Do not spray flammable gases such as insecticide near the air conditioner Potential risk of electri...

Page 7: ...material and used batteries of the remote controller optional must be disposed of in accordance with the national standards The refrigerant used in the air conditioner must be treated as chemical was...

Page 8: ...must be accessible and that can be disassembled in conditions of complete safety either for people or things For this reason where it is not observed as indicated into the Installation Manual the cost...

Page 9: ...s via the unit control system 29 Storing the remote controller APPENDIX 30 30 Troubleshooting 31 Operation ranges contents VIEWING YOUR AIR CONDITIONER 10 10 Checking the indoor unit and display 10 Ma...

Page 10: ...ack your air conditioner and check the indoor unit to make sure it is not damaged Main parts Your air conditioner may slightly look different from illustration shown above depending on your model Air...

Page 11: ...r Air swing Left Right button Mode selection button Fan speed adjustment button Temperature adjustment buttons On Off button Air swing Up Down indicator Remote control sensor Air swing Left Right indi...

Page 12: ...peration modes see pages 14 18 for instructions Fan Adjust how much air flows through the air conditioner with the 4 different fan speeds such as Auto Low Medium High Air swing Up Down Activate Deacti...

Page 13: ...location of remote control receiver When you properly press the button on the remote controller you will hear ring sound from the indoor unit The signal may not be received well of electronic lighting...

Page 14: ...e and Auto fan speed indicator appear on the remote controller display The air conditioner will automatically set the operation mode to Cool or Heat depends on the room temperature Cooling only model...

Page 15: ...the temperature by 1 C 4 Set the fan speed Press the Fan or button on the remote controller to set the desired fan speed If room temperature reaches desired value the air conditioner will shut off co...

Page 16: ...de will change in order of Cool Auto Dry Fan Heat pump model AP N1A Each time you press the Mode button the mode will change in order of Auto Cool Dry Fan Heat 3 Set the temperature Press the Temp or...

Page 17: ...uto Dry Fan Heat pump model AP N1A Each time you press the Mode button the mode will change in order of Auto Cool Dry Fan Heat 3 Set the fan speed Press the Fan or button on the remote controller to s...

Page 18: ...30 C You can increase decrease the temperature by 1 C 4 Set the fan speed Press the Fan or button on the remote controller to set the desired fan speed If room temperature reaches desired value heatin...

Page 19: ...nt position press the Air swing Up Down button on the remote controller again Horizontal air flow 1 Press the Air swing Left Right button on the remote controller The air flow blades move right and le...

Page 20: ...is most recent mode used Turbo function is only available in Auto Cool Heat mode If Turbo function is selected in Dry Fan mode operation mode changes to Auto Heat mode is applicable for AP30N1A model...

Page 21: ...an mode operation mode changes to Auto Heat mode is applicable for AP30N1A model only When using Long function the air flow blades face upward and vertical air flow direction control is not possible Y...

Page 22: ...s you have set for 3 seconds and set desired temperature will display The air conditioner will operate automatically at set time and then On timer indicator stops blinking and stays on If On timer is...

Page 23: ...he remote controller display will show the hour s you have set for 3 seconds and set desired temperature will display The air conditioner will operate automatically at set time and then Off timer indi...

Page 24: ...of the On Timer is 3 hours and the Off Timer is 5 hours the air conditioner will turn on after 3 hours from the moment you have set the timer Your air conditioner will remain on for 2 hours and then t...

Page 25: ...18 C 30 C in Cool mode 16 C 30 C in Heat mode Heat mode is applicable for AP30N1A model only You can increase decrease the temperature by 1 C 3 Press the Fan Speed button to adjust the fan speed Each...

Page 26: ...LOCKING THE CONTROL PANEL You can lock the control panel on the indoor unit to prevent the children from playing with the air conditioner When the air conditioner is on or off 1 Press the Temp and bu...

Page 27: ...ter can be cleaned with a vacuum or by hand washing 1 Open the cover of air intake and then take the Air filter out 2 Clean the Air filter with a vacuum cleaner or soft brush If dust is too heavy use...

Page 28: ...xchanger 2 Clean the condensate drain pipe 2 Replace the remote controller batteries 1 Outdoor unit Clean the heat exchanger on the outside of the unit 2 Clean the heat exchanger on the inside of the...

Page 29: ...conditioner does not start operating immediately to protect the compressor of the outdoor unit after it has been started If the heat pump is operating in Heat mode defrost cycle is actuated to remove...

Page 30: ...coming out The fan speed does not change Check if you selected Auto or Dry mode The air conditioner automatically adjusts the fan speed to Auto in Auto Dry mode Timer function does not set Check if y...

Page 31: ...or drops on the floor HEATING 27 C or less 5 C to 24 C Internal protection triggers and the air conditioner will stop DRYING 18 C to 32 C 21 C to 54 C Condensation may occur on the indoor unit with r...

Page 32: ...AP28N0A_IB_E_31713 1 indd 32 2010 02 10 12 48 38...