Page 1: ...ⒺⓈDB68 00052A 2 FLOOR STANDING TYPE AIR CONDITIONER Cool OWNER S INSTRUCTIONS INSTALLATION MANUAL AP 3607BR ...
Page 2: ... Turbo Operating Mode Selecting the Mild Operating Mode Removing Excess Humidity Ventilating Your Room Adjusting the Air Flow Direction Horizontally Adjusting the Air Flow Direction Vertically PROGRAMMING YOUR AIR CONDITIONER Setting the Timer Setting the Quick Timer Cancelling the Timer Cancelling the Quick Timer RECOMMENDATIONS FOR USE Operating Recommendations Safety Precautions Temperature and...
Page 3: ...l advantage of the unit s features The booklet is organized as follows The following figures are shown on page 4 page 6 and page 7 Remote control buttons and display Indoor unit Outdoor unit They will help you find the buttons and switches and understand the symbols displayed In the main part of the document you will find a series of step by step procedures for each function available The illustra...
Page 4: ...ting ON OFF Button Fan speed adjustment Air flow adjustment Timer setting cancellation Time adjustment Timer adjustment Operating mode Temperature display Mode indicators AUTO COOL DRY FAN Setting display Fan speed Air flow direction Mild setting Automatic stop Q Timer adjustment Time Timer display Current time Timer settings Temperature adjustment ...
Page 5: ...he arrow 1 2 3 You must insert or replace the remote control batteries when You purchase the air conditioner The remote control does not work correctly Use two LR03 1 5V batteries Do not use old batteries or different kinds of batteries together Batteries may not be usable after 12 months though they have not been used IMPORTANT Remote control case When the following indication is displayed replac...
Page 6: ...OL PANEL REMOTE CONTROL SENSOR AIR INLET GRILLE AUTO SHUTTER Each time you can press the ON OFF button it open or close automatically To disassemble the air inlet grille Loosen two fixing screws of left and right Hold the upper part of the air inlet grille and then pull it lightly forward ...
Page 7: ...ON VALVE Control Panel Temperature adjustment Operating Light ON OFF Button Fan Light Operating Light Mild setting Automatic stop Fan Speed adjustment Turbo setting Operating Mode Selection Temperature display Open the control panel by pushing a part of it ...
Page 8: ...ime during the operation Open the lid on the rear side of the remote control and press the time set button using a tool with a sharp end point Result The TIME indicator flashes Result AM or PM are displayed to indicate whether the setting corresponds to a time before or after midday 3 2 Each time the button is pressed the time increases by one minute When the button is continually pressed the time...
Page 9: ... the unit the power switch is fitted to the wall must be set to ON IMPORTANT You can operate with indoor unit when you do not wish to or cannot operate the air conditioner with the remote control You can Adapt the auto operating cooling turbo operating mild operating drying and fan settings to your specific requirements All air conditioner features can be controlled from your seat by using the rem...
Page 10: ...it appears Result The indoor unit beeps each time you press MODE The air conditioner starts up in AUTO mode 2 You can however change modes at any time when the air conditioner is operating How to control the standard temperature When the unit is in automatic operation mode the standard temperature is automatically set However the standard temperature can be adjusted up to 2 C 4 F by pressing the T...
Page 11: ...he ON OFF button Result The OPER light on the indoor unit switches on The operation mode previously set is displayed The indoor unit beeps twice The air conditioner starts up in the current mode 1 Press MODE under the remote control flap one or more times until the COOL indicator is displayed 2 Select the temperature by pressing the TEMP SET or buttons one or more times until the required temperat...
Page 12: ...e set temperature and air flow quantity to ensure pleasant operation during sleeping or when used by elderly people The mild operation function stops automatically after operating for three hours When the unit is in the mild operation mode the set temperature and air flow quantity are automatically controlled Therefore it is not necessary to make any separate selection Press the MILD button again ...
Page 13: ...ode the air flow quantity is automatically set Therefore it is not necessary to select the air flow quantity separately If necessary press the ON OFF button Result The OPER light on the indoor unit switches on The operation mode previously set is displayed The indoor unit beeps twice The air conditioner starts up in the current mode 1 Press MODE under the remote control flap one or more times unti...
Page 14: ...eps Press MODE under the remote control flap one or more times until the FAN indicator is displayed 2 Select the fan speed by pressing the FAN SPEED button one or more times until the required setting is displayed 3 If necessary press the ON OFF button Result The OPER light on the indoor unit switches on The operation mode previously set is displayed The indoor unit beeps twice The air conditioner...
Page 15: ... the horizontal blades in the disired direction 1 1 To stop the blades press the L R SWING button 2 Just as the air flow blades can be adjusted vertically they can also be adjusted by the hands Effective control of air flow direction Adjust the blades to face upward for cooling Adjusting the Air Flow Direction Horizontally Adjusting the Air Flow Direction Vertically To set to the required position...
Page 16: ... Press the TIMER ON button Result The TIMER indicator is displayed The ON indicator flashes The preset time is displayed 1 5 When you are satisfied with the start time press SET TIMER Result The indoor unit beeps The TIMER light switches on The unit is switched off and will start up automatically when the start time is reached 6 Press the TIMER OFF button 7 Indicate the time at which you wish to s...
Page 17: ...one hour two hours three hours five hours When the set period has elapsed the operation stops automatically Press the Q TIMER button Each time the button is pressed the following are displayed sequentially Result The Q TIMER indicator is displayed When the timer operation function starts the remaining time is displayed on the remote control 2 Setting the Quick Timer NOTE The quick timer function a...
Page 18: ...ally To cancel the start time press TIMER ON Result The ON indicators flash 1 To cancel the stop time press TIMER OFF Result The OFF indicators flash 3 If you no longer wish to use the Quick timer function you can cancel it at any time Press the Q TIMER button Set the button so that is displayed After the elapse of five seconds the current time is displayed and the quick timer is cancelled Result ...
Page 19: ... of any kind into the indoor unit Should this happen turn the power switch off and contact your installation specialist 2 Do not insert anything between the air outlet blades as the inner fan may be damaged and you may be hurt Particularly keep children away from the indoor unit 3 Always ensure that the power cable is in good condition Make sure that it is not walked on or damaged by items placed ...
Page 20: ...r conditioner ensure that it is switched off 1 Loosen two fixing screws of left and right Pull the inlet grille lightly and pull out the air filter in an upward direction to release them If the cooling operation is used at over 33 C 92 F indoor temperature then does not a full capacity 2 Remove all dust on air filters with a vacuum cleaner or brush In case of serious dust accmulation put the dust ...
Page 21: ...rogrammed correctly see page 16 The timer is not triggered correctly Ventilate the room Smells are permeated in the room during air conditioning The indoor unit and the remote control can be different each other because the room temperature always is not equal The temperature display on the indoor unit is different from one on the remote control Turn the power switch off Contact your installation ...
Page 22: ...id Line O D in Suction Line O D in Connections Factory Pre charge ft Max Line Length ft Max Height Difference ft Performance Ratings Electrical Data Dimension Weight Refrigeration Lines ITEM MODEL Indoor unit AP 3607BR Outdoor unit AP 3607BRX 36000 10 85 776 3 1 208 230 60 3800 18 30 23 x 75 x 16 40 x 33 x 16 3 8 5 8 Flare 38 82 49 56 62 62 125 189 Standard rating conditions Cooling Indoor DB 26 7...
Page 23: ...E 23 MEMO ...
Page 24: ...THIS AIR CONDITIONER IS MANUFACTURED BY Printed in Korea ...
Page 25: ...are of the installation of your unit the user should not attempt to install his her unit by himself herself Do not attach any electric heating device or electric heater to the unit Do not attempt to disassemble or modify the unit by yourself It may cause machine trouble electric shock or fire 1 Drain check 2 Drilling a hole in the wall Refer to page 31 for detailed procedures Ø60mm 2 inch Less tha...
Page 26: ...lder for outdoor unit Connection piping Connection piping Ø15 8mm 5 8 Connection wiring 3 strand Connection wiring Insulation for piping 5 8 Finishing tape Insulation tape Insulation tube for indoor unit piping connection Ring terminal Q ty Q ty Remarks Remarks Part Name 1 2 3 4 5 6 7 8 9 10 11 3 4 4 4 2 2 2 7 1 1 Piping box Option piping box 4N 6N 1 1 Indoor unit Connection Parts Others Ø9 52mm 3...
Page 27: ...Install the unit at a place close to the wall facing the outside as it is necessary to perform piping connection with the outdoor unit It is effective to install the unit at a window side to ensure uniform distribution of indoor temperature Install the unit at a place where there is no obstacle against the wind around the air inlet and air outlet Install the unit horizontally at a stable rigid pla...
Page 28: ... 2 3 1 2 3 1 2 Rojo Blanco Negro 1 2 3 1 2 3 RED WHT BLK 1 2 3 RED WHT BLK 1 2 3 1 2 3 Rojo Blanco Negro Indoor wiring connector Indoor outdoor unit connecting wire Terminal board Electric panel board Electric panel board INDOOR SIDE OUTDOOR SIDE Earth wire Earth wire The electrical work should be performed by a specialist qualified for the work Use the single phase power supply and be sure to ins...
Page 29: ...d the fixing holder as shown in the right figure 2 Fix the fixing holder to the screw on the upper part of the indoor unit 3 Fix the unit to the wall surface using the screw or anchor bolt The screw of the fixing holder is Ø6mm in diameter 1 Fix the unit on a flat rigid floor using the anchor bolt Anchor bolt M10 x 4 points separately purchased 1 Insert the foot holder 4EA 2 Remove the nut fastene...
Page 30: ...he heat exchanger gas pipe respectively using the flare nut taking care not to cause any leakage of refrigerant 4 Be sure to insulate the pipe with appropriate insulation material 5 Insert the drain hose into the drain pipe and connect them by tying them to the cable tie to prevent any water leakage 6 After completion of the installation check the connecting area for any gas leakage 7 Wind a finis...
Page 31: ...ing and unbending the pipe more than twice makes the bending work increasingly difficult 3 You may use the spring inserted into the gas pipe instead of the bender to bend the pipe 4 When you bend the pipe using the spring hold the pipe with both hands to prevent any distortion and secure a minimum bending radius of more than 100mm 4inch Align the center of the connection piping and tighten the fla...
Page 32: ...Piping Material Insulator Vinyl Chloride Inner diameter Ø18mm 0 71inch Outer diameter Ø 23mm 0 91inch Foamed Polyethylene Caution 1 As the draining is of natural drain type make the drain hose direct downward 2 If there is any foreign substance in the drain plate it may clog the drain pipe Therefore be sure to remove the foreign substance inside after installation 3 After completion of installatio...
Page 33: ...om the system using vacuum pump for about 10 minutes Close the valve of the low pressure side of manifold gauge clockwise Remove the hose of the low pressure side of manifold gauge 4 Set valve cork of both liquid side and gas side of packed valve to the open position 5 Mount the valve stem nuts to the 3 way valve And mount the service port cap to 3 way valve 6 Check for gas leakage At this time es...
Page 34: ...Check the pressure of the pressure gauge Check whether the low pressure side is within the range of 4 5 5 5kg cm2 G outside temperature 35 C 95 F Start cooling operation Connect it to the refrigerant filling tank Turn the tank upside down Fill the refrigerant in liquid form Close the gas pipe side valve by turning it clockwise Connect the pressure gauge to the low pressure side service valve and t...
Page 35: ...k the piping connection area for any gas leakage 2 Is the drain hose properly connected 3 Is the insulation of the piping in good condition 4 Is grounding properly made Outdoor connection area Check Insulation Indoor connection area CHECK AND TEST OPERATION CHECK AND TEST OPERATION ...
Page 36: ... test operation 2 Never attempt to start test operation by force pressing the electronic contactor as it is very dangerous This is very dangerous as the protective device does not work 3 Be sure to perform the test operation after installment It is easy to start the test operation in winter if you increase the sensor temperature to 23 C 73 4 F 25 C 77 F by holding the indoor temperature sensor Do ...