ENGLISH-18
Cleaning and maintaining the air conditioner
Maintaining the air conditioner
If the air conditioner will not be used for an extended period of time, dry the air conditioner to maintain it in best condition.
1. Dry the air conditioner thoroughly by operating in Fan mode for
3 to 4 hours and turn off the circuit breaker. There may be internal
damage if moisture is left in components.
2. Before using the air conditioner again, dry the inner components of
the air conditioner again by running in Fan mode for 3 to 4 hours.
This helps remove odors which may have generated from dampness.
Periodical checks
Refer to the following chart to maintain the air conditioner properly.
Type
Description
Every 2 weeks Every 4 months
Once a year
Indoor
unit
Clean the air filter (1)
●
Clean the condensate drain pan (2)
●
Thoroughly clean the heat exchanger (2)
●
Clean the condensate drain pipe (2)
●
Outdoor
unit
Clean the heat exchanger on the outside of the unit (2)
●
Clean the heat exchanger on the inside of the unit (2)
●
Clean the electric components with jets of air (2)
●
Verify that all the electric components are firmly
tightened (2)
●
Clean the fan (2)
●
Verify that all the fan assembly is firmly tightened (2)
●
Clean the condensate drain pan (2)
●
●
: This check mark requires checking the indoor/outdoor unit periodically, following to the description to maintain the air
conditioner properly.
• The checks and maintenance operations described are essential to guarantee the efficiency of the air
conditioner. The frequency of these operations varies according to the characteristics of the area, the amount
of dust, etc.
1) The described operations should be performed more frequently if the area of installation is very dusty.
2) These operations must always be performed by qualified
personnel. For more detailed information, see the Installation
part.
CAUTION
PAC SUPER_AM096HNPDCH_IB_EN_DB68-04904A-00.indd 18
2014-09-18 오전 9:44:21