Samsung AHT18P1HBA Owner'S Instructions Manual Download Page 1

E A

DB98-17029A(

5

)

OWNER’S

INSTRUCTIONS

AHT18P1HBA/BB

      

            AHT18U1HBA/BB

AHT18P1HEA/EB/EC             AHT18U1HEA/EB/EC

AHT24P1HBA/BB

     

            AHT24U1HBA/BB

AHT24P1HEA/EB/EC             AHT24U1HEA/EB/EC

Window-type Room Air Conditioner 

( Cool and Heat)

Summary of Contents for AHT18P1HBA

Page 1: ...DB98 17029A 5 OWNER S INSTRUCTIONS AHT18P1HBA BB AHT18U1HBA BB AHT18P1HEA EB EC AHT18U1HEA EB EC AHT24P1HBA BB AHT24U1HBA BB AHT24P1HEA EB EC AHT24U1HEA EB EC Window type Room Air Conditioner Cool and Heat ...

Page 2: ...power source which must be installed in compliance with national wiring earthing and safety regulations If the power cord is damaged in any way it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard This device must be installed according to the national electrical rules The appliance must be installation that the plug should be easi...

Page 3: ...oom 6 Cooling Your Room 7 Airing Your Room 8 Switching the Air Conditioner Off 8 Adjusting the Air Flow Direction Horizontally 9 Adjusting the Air Flow Direction Vertically 9 RECOMMENDATIONS FOR USE Operating Recommendation 10 Temperature and Humidity Ranges 11 Cleaning Your Air Conditioner 12 Solving Common Problems 13 Technical Specifications 14 METHOD OF INSTALLATION 15 E 3 ...

Page 4: ...ntation Air inlet Outside Air inlet Inside Air filter Inside The design and shape are subject to change depending on the model Power Cable Power cable connection should be committed to an installation engineer BLUE BROWN YELLOW GREEN Main Power Earth Temperature control dial Cooling lamp Operating mode selection dial Air flow blade swing switch E 4 ...

Page 5: ...read them as they will help you take full advantage of the unit s features The booklet is organized as follows The illustration on page 4 shows the air conditioning unit it indicates the location and purpose of the main parts and controls on the unit In the manual you will find a series of step by step procedures for each function available The illustrations in the step by step procedures use four...

Page 6: ... Heat mode The fan starts up at the speed selected You can change modes at any time You must select the HEAT mode if you wish to higher the temperature in your room You can also set the fan speed To adjust the temperature turn the temperature control dial to the red position Left side Result The air conditioner is started heating if room temperautre is lower than selected temperature To control th...

Page 7: ...ed selected You can change modes at any time You must select the Cool mode if you wish to lower the temperature in your room You can also set the fan speed 1 2 To control the direction of the air flow refer to page 9 3 To adjust the temperature turn the temperature control dial to the blue position Right side Result The air conditioner is started cooling as turn on the cooling lamp if room tempera...

Page 8: ...er you want 1 1 Set the operating mode selection dial to the position Result The air conditioner starts up in Fan mode The left right have it s same function 2 To control the direction of the air flow refer to page 9 3 If you wish to evacuate stale air outside push the ventilation lever on the front of the unit to the right and the open position Result The air inside the room circulates and stale ...

Page 9: ...rection simply set the switch to the position when the blades are in the desired position 2 Set the air flow blade swing switch to the position Result The inner blades swing automatically left and right Again depending on the position of the unit in your room you can adjust the orientation of the outer air flow blades on the right hand side of the unit RECOMMENDATION When Cooling Adjust the blades...

Page 10: ...erating the unit is switched off When the power returns the air conditioner starts up again automatically Power failure The air conditioner circulates warm air to heat your room as a result some time will be required after starting the air conditioner to warm the entire room If necessary set the air conditioner going a short time before you wish to use the room Warm air circulation E 10 ...

Page 11: ...er freezes Higher humidity levels Water may condense on and drip from the surface of the unit if it is used for long periods The following table indicates the temperature and humidity ranges within which the air conditioner can be used Mode Indoor Temperature Outdoor Temperature Indoor Humidity Heating 28 C or less 0 C to 21 C approx Cooling 21 C to 32 C approx 21 C to 54 C approx 80 or less Tempe...

Page 12: ...ed insert the air filter back into its original position 4 Wipe the surface of the unit with a neutral detergent and then wipe it again with dry cloth Be sure not to use benzene solvent or other chemical products 5 The removal of the front grille makes it easier to clean the air conditioner Open the grille as much as possible Be sure to clean the air filter periodically two weeks to maintain the a...

Page 13: ...the air filter refer to page 12 for cleaning instructions Check that there is no obstacle blocking the air flow into or out of the unit PROBLEM The air conditioner does not operate at all The air conditioner does not cool Check that the air conditioner has been switched on if necessary turn the operating mode selection dial The air flow direction does not change when you set the air flow blade swi...

Page 14: ... 60Hz E 14 Design and specifications are subject to change without notice Power Supply Model AHT18P1HBA BB AHT18U1HBA BB AHT24P1HBA BB AHT24U1HBA BB 220 240V 50Hz AHT18P1HEA EB EC AHT18U1HEA EB EC AHT24P1HEA EB EC AHT24U1HEA EB EC ...

Page 15: ... is advisable to install the air conditioner in the north or west side to prevent the effect of direct sunlight When installing it in the south or east side due to unavoidable circumstances it is advisable to install the sunshade to prevent the direct sunlight In this case take care not to cause any hindrance to the flow of outside air 2 When installing the air conditioner be sure to obtain suffic...

Page 16: ...es of the cabinet in the direction of the arrow as shown in the figure 2 2 Pull the lower part of the front panel slightly forward below three inches 2 3 Lift the front panel upward 2 Applying excessive force to remove the front panel may cause damage to the tab be sure not to use excessive force Rubber cap Screws 2EA Gasket Rear Drain Tube Front panel E 16 Removal and Reassembly of the Front Gril...

Page 17: ...e figure and then connect the drain hose You can use any commercially available drain hose 7 Install the cabinet at the specified area after installing the drain pan and then re assemble it in the original condition When assembling the front panel be sure to fix with a supplied screw TH 2S 4X10 6 Follow steps 5 and 6 only 1 Rear Screw Drain Pan Rubber cap Drain Hose Bottom Side View with Drain Pan...

Page 18: ...THIS AIR CONDITIONER IS MANUFACTURED BY ...