Category
Description
HRU
M6 × L12 SEMS (Hex.+)/2 EA
Recommended
Torque Value
M6 SEMS
43 lbf·in (50 kgf·cm)
Working Tools
Cable Cutter
Wire Stripper
Crimping tool
Heating Gun
Nipper
Screw Driver (‘+’, Number 3)
Torque Driver (20 to 90 lbf·in.)
Screw Driver Bit (‘+’, Number 3)
For the pressure terminals of the cable, the UL listed products or equivalent must
be used.
For example, Manufacturer-Panduit
- HRU: 6 AWG Pressure Terminal (LCD6-14AF-L)
1
Install the ground cable from the MGB to the HRU ground terminal, as shown
in figure below:
Figure 92.
Connecting Ground Cable (1)
2
Assemble a pressure terminal and a heat shrink tube at the end of the HRU
ground cable.
3
Align the pressure terminal to the mounting hole of the HRU ground terminal.
4
Firmly fix the pressure terminal onto the HRU ground terminal using
fasteners.
[Bottom View]
MGB