General safety instructions

1  General safety instructions

For your own safety, follow these instructions concerning the mounting, start up, and opera-

tion of the thermostat:

 

The thermostat is to be mounted, started up or operated only by trained and experienced 
personnel familiar with the product.
According to these mounting and operating instructions, trained personnel refers to 
individuals who are able to judge the work they are assigned to and recognize possible 
dangers due to their specialized training, their knowledge and experience as well as 
their knowledge of the applicable standards.

 

Upon installation of the electric cables and connecting the device, observe the VDE 
regulations as well as the regulations of your local power supplier. Make sure all 
electrical connections are installed only by trained and experienced personnel.

To avoid damage to any equipment, the following also applies:

 

Proper shipping and storage are assumed.

The device with a CE marking fulfills the requirements of the Directives 2014/30/EU and 
2014/30/EU, 2014/35/EU and 2011/65/EU.
The EU declarations of conformity are included in the Appendix of these instructions.

Note

Summary of Contents for EB 5206 EN Series

Page 1: ...or STM Type 5344 Temperature Regulator TR Type 5345 Safety Temperature Limiter STL Type 5347 Double Thermostat TR STL Type 5348 Double Thermostat TR STM Type 5349 Double Thermostat STM STL Thermostats...

Page 2: ...fter sales Service Department aftersalesservice samson de The mounting and operating instructions for the devices are included in the scope of delivery The latest documentation is available on our web...

Page 3: ...tion 10 3 2 Contact thermostat 11 3 3 Mounting the thermowell 11 3 3 1 Wall mounting with the capillary tube to the thermowell 12 3 3 2 Mounting on tanks or in pipes 12 4 Electrical connection 14 5 Op...

Page 4: ...rs due to their specialized training their knowledge and experience as well as their knowledge of the applicable standards Upon installation of the electric cables and connecting the device observe th...

Page 5: ...ube breaks Temperature regulator TR The snap action switch is triggered when the temperature at the temperature sensor rises above the adjusted set point When the tem perature falls below the set poin...

Page 6: ...t 0 25 A NO contact 0 25 A Safety temperature limiter STL With 230 V AC 10 NC contact 16 A 2 5 cos 1 0 6 Signal contact 2 A 2 5 cos 1 0 4 With 230 V DC 10 NC contact 0 25 A Signal contact 0 25 A Influ...

Page 7: ...mperature regulators TR 5344 1 0 to 120 C 3 K Range 0 to 80 C 7 2 K 7 2 K 145 C Range 80 to 120 C 3 6 K 3 6 K 5344 2 20 to 150 C 4 K Range 20 to 106 C 7 8 K 7 8 K 175 C Range 106 to 150 C 3 9 K 3 9 K...

Page 8: ...3 K Range 0 to 80 C 7 2 K 7 2 K 145 C Range 80 to 120 C 3 6 K 3 6 K STM 70 to 130 C 8 K Range 70 to 130 C 0 K 8 5 K 5348 2 TR 0 to 120 C 3 K Range 0 to 80 C 7 2 K 7 2 K 125 C Range 80 to 120 C 3 6 K 3...

Page 9: ...9848 150x8 mm 88 bar 1400 9849 300x8 mm 88 bar 1400 9850 Thermowell for double thermostat Max pressure at 150 C Order no Nickel plated brass CuZn 2 0401 100 x 2x 8 mm 48 bar 1400 9901 150 x 2x 8 mm 4...

Page 10: ...an 5 mm Table 1 Properties of the measuring fluid Dangerous reaction No Ignition temperature 375 C Water hazard Class 1 Slightly contaminating Toxicological specifications Irritant No Health hazard No...

Page 11: ...same thermowell See section 2 3 Before fastening the thermostat uncoil the capillary tube to the required length For wall mounting the required length depends on the required capillary tube and length...

Page 12: ...the set point adjuster onto the tem perature regulator 3 3 2 Mounting on tanks or in pipes The thermostats are fastened to the thermow ells which are screwed into place 7 Insert the seal 6 8 Screw the...

Page 13: ...ry tube Fig 4b Wall mounting with the capillary tube to the thermowell Fig 4c Mounting on tanks or in pipes 1 7 7a 3 6 2 1 Thermostat 2 Sensor 3 Capillary tube 6 Seal 7 Thermowell 7a Clip 7b Metal pla...

Page 14: ...the cable gland M20x1 5 into the inside of the thermostat The spring clamp terminals are designed for a wire cross section of 0 75 to 2 5 mm Wiring Open the thermostat housing and wire the thermostat...

Page 15: ...point adjuster back on the temperature regulator 5 2 Safety temperature mon itor STM Open the thermostat housing and adjust the set point using a flat blade screwdriver 5 3 Safety temperature limiter...

Page 16: ...gray colored area Drill the holes for lead sealing The lead seal is not included in the scope of delivery 8 16 15 30 NOTICE Note 6 Dimensions in mm Single thermostats Type 5343 Safety Temperature Moni...

Page 17: ...4 5 95 6 Housing without ther mowell G1 2 8 70 300 200 150 100 15 5 Type 5345 Safety Temperature Limiter STL Dimensions with thermowell accessories C 120 150 53 42 4 22 4 5 95 6 Housing without ther m...

Page 18: ...TL Dimensions with thermowell accessories C 120 150 106 95 4 22 4 5 95 6 Housing without ther mowell G1 2 15 70 100 150 300 5 Type 5348 Double Thermostat TR STM Dimensions with thermowell accessories...

Page 19: ...49 Double Thermostat TR STM Dimensions with thermowell accessories C 120 150 106 95 4 22 4 5 95 6 G1 2 15 100 150 300 63 58 5 Housing without thermowell Metal plate and screw for fastening the thermos...

Page 20: ...n Responsable de l assurance de la qualit Development Automation and Integration Technologies ce_5344 0_de_en_fra_rev07 pdf SAMSON AKTIENGESELLSCHAFT Weism llerstra e 3 60314 Frankfurt am Main Telefon...

Page 21: ...l assurance de la qualit Development Automation and Integration Technologies ce_5347 0_de_en_fra_rev07 pdf SAMSON AKTIENGESELLSCHAFT Weism llerstra e 3 60314 Frankfurt am Main Telefon 069 4009 0 Telef...

Page 22: ...n Responsable de l assurance de la qualit Development Automation and Integration Technologies ce_5349 0_de_en_fra_rev07 pdf SAMSON AKTIENGESELLSCHAFT Weism llerstra e 3 60314 Frankfurt am Main Telefon...

Page 23: ...EB 5206 EN 23...

Page 24: ...2018 07 03 English SAMSON AKTIENGESELLSCHAFT Weism llerstra e 3 60314 Frankfurt am Main Germany Phone 49 69 4009 0 Fax 49 69 4009 1507 samson samson de www samson de EB 5206 EN...