Samson 1634666 Instruction Manual Download Page 8

M6 set screw

Note:

Capacity curve

• 

Install the vacuum limiter on the suction line by using the 1” BSP thread.

• 

Connect the hose to the suction line by using the 1/8” BSP nipple hose and the two straps, which are 
included in the kit.

• 

If you have an exsisting installation, you are able to use M6 nipple hose on your suction line.

Step 1) When the pump is running, close the valve by turning the M6 set 
screw counter clockwise (-direction)

Step 2) Open the valve by turning the set srew clockwise (+direction), until 
the required set pressure is reached.

It is recommended to adjust the valve to the lowest set pressure as possible to avoid cavitation in the pump 
and unacceptable noise from the air inlet.

3.1 Installation

3 INSTALLATION & ADJUSTMENT

3.2 Adjustment

DOC1634666_2

DOC1627080

DOC1627077

A failure to comply the adjustment described below, may result in damage to the 
vacuum limiter. 

• 

The vacuum limiter may not be installed if it is damaged.

• 

Repair of vacuum limiter used in Ex zones is not allowed.

8

Summary of Contents for 1634666

Page 1: ...DOC4000G INSTRUCTION MANUAL FOR SAMSON VACUUM LIMITER VACUUM LIMITER INSTRUCTION MANUAL Accessories Technical data Functional description Installation Adjustment ATEX APPLICABLE...

Page 2: ...2...

Page 3: ...of incorporation 4 1 2 Explanation of warning symbols 5 1 3 Functional description 5 2 Technical data 6 2 1 Materials 6 2 2 Sectional drawing 6 2 3 Dimensions 7 3 Installation adjustment 8 3 1 Install...

Page 4: ...on source The ATEX Directive 2014 34 EU does not apply to this product The product may be used within the Ex area Applied harmonized standards in particular DS EN 1127 1 2011 Explosive atmospheres Exp...

Page 5: ...supplied to the suction side of the pump through the vacuum limiter which is regulated according to the required pressure Cavitation arises when the pressure in the pump falls to under the steam press...

Page 6: ...5 Membrane housing lower PEHD antistatic 6 Spring guide POM 7 M6x25 allen screw DIN 912 A4 8 M6 nut DIN 934 A4 9 M6 washer A4 10 M6 set screw DIN 916 A4 11 O ring 8x2 NBR Shore 70 12 Spring A2 13 O r...

Page 7: ...45 136 30 15 1 BSP 80 0 80 5 Nipple hose 6 1 8 BSPT 2 3 Dimensions DOC1634666_1 Weight kg 0 5 Vacuum limiter 7...

Page 8: ...w counter clockwise direction Step 2 Open the valve by turning the set srew clockwise direction until the required set pressure is reached It is recommended to adjust the valve to the lowest set press...

Page 9: ...Notes Vacuum limiter 9...

Page 10: ...Notes 10...

Page 11: ...Notes Vacuum limiter 11...

Page 12: ...ough to simply produce a pump Products must be refined so the customer can concentrate on what they do best We therefore offer a wide range of standardised components that allow our customers to build...