To be used with all safety instructions that must be followed. A failure to follow the 
instructions may result in injury and/or incorrect machine operation.

1.2  Explanation of warning symbols

Pilot pressure

Air inlet

Air inlet

Adjustment

Air outlet

The SAMSON Vacuum Limiter Valve is designed to control the pressure (vacuum) level and to avoid 
cavitation in the pump.

The Vacuum Limiter Valve is installed when the suction line may force the pump to operate below the 
cavitation limit. Air must then be supplied to the suction side of the pump through the vacuum limiter, 
which is regulated according to the required pressure.

Cavitation arises when the pressure in the pump falls to under the steam pressure for the service liquid, 
which makes the liquid boiling and steam bubbles arise in the service liquid. Continuous operation will 
cause great mechanical damage.

1.3  Functional description

Air outlet

DOC1634089_4

The SAMSON vacuum limiter is exclusively designed for SAMSON liquid ring pumps!

Important technical and safety instructions is showed by symbols. If instructions are not performed 
correctly, it may lead to personnel injury or incorrect function of the vacuum limiter. 

(Vacuum)

Vacuum limiter

5

Summary of Contents for 1634666

Page 1: ...DOC4000G INSTRUCTION MANUAL FOR SAMSON VACUUM LIMITER VACUUM LIMITER INSTRUCTION MANUAL Accessories Technical data Functional description Installation Adjustment ATEX APPLICABLE...

Page 2: ...2...

Page 3: ...of incorporation 4 1 2 Explanation of warning symbols 5 1 3 Functional description 5 2 Technical data 6 2 1 Materials 6 2 2 Sectional drawing 6 2 3 Dimensions 7 3 Installation adjustment 8 3 1 Install...

Page 4: ...on source The ATEX Directive 2014 34 EU does not apply to this product The product may be used within the Ex area Applied harmonized standards in particular DS EN 1127 1 2011 Explosive atmospheres Exp...

Page 5: ...supplied to the suction side of the pump through the vacuum limiter which is regulated according to the required pressure Cavitation arises when the pressure in the pump falls to under the steam press...

Page 6: ...5 Membrane housing lower PEHD antistatic 6 Spring guide POM 7 M6x25 allen screw DIN 912 A4 8 M6 nut DIN 934 A4 9 M6 washer A4 10 M6 set screw DIN 916 A4 11 O ring 8x2 NBR Shore 70 12 Spring A2 13 O r...

Page 7: ...45 136 30 15 1 BSP 80 0 80 5 Nipple hose 6 1 8 BSPT 2 3 Dimensions DOC1634666_1 Weight kg 0 5 Vacuum limiter 7...

Page 8: ...w counter clockwise direction Step 2 Open the valve by turning the set srew clockwise direction until the required set pressure is reached It is recommended to adjust the valve to the lowest set press...