4.5 Prior to start-up
• Do not start the pump without service liquid, as this will damage the mechanical shaft
seals
• Do not start the pump if it is completely filled with service liquid
• Do not start the pump before the grease cartridges have been activated, as this can
damage the pump (if equipped)
• Stop the pump immediately if the rotational direction does not correspond to the
directional arrow
• A failure to follow the above guidelines may result in damage to the pump
4.6 Direction of rotation
Check the direction of rotation by briefly starting the pump.
The direction of rotation of the rotor must correspond to the direction arrow!
Below left, a right-side pump is shown which has a clockwise direction of rotation (CW)
Below right, a left-side pump is shown which has a counter-clockwise direction of rotation (CCW)
Activating the grease cartridges (Accessories)
Turn the handle in NDE clockwise to position 12.
Turn the handle in DE clockwise to position 12.
The pump has been lubricated from factory and is ready to start.